How to make usage of the standardized EuroFlow 8-color protocols possible for instruments of different manufacturers.
EuroFlow
Flow cytometry
Fluorescent spectrum
Fluorochromes
Standardization
Journal
Journal of immunological methods
ISSN: 1872-7905
Titre abrégé: J Immunol Methods
Pays: Netherlands
ID NLM: 1305440
Informations de publication
Date de publication:
12 2019
12 2019
Historique:
received:
25
03
2017
accepted:
14
11
2017
pubmed:
21
11
2017
medline:
12
5
2020
entrez:
21
11
2017
Statut:
ppublish
Résumé
A critical component of the EuroFlow standardization of leukemia/lymphoma immunophenotyping is instrument setup. Initially, the EuroFlow consortium developed a step-by-step standard operating protocol for instrument setup of ≥8-color flow cytometers that were available in 2006, when the EuroFlow activities started. Currently, there are 14 instruments from 9 manufacturers capable of 3-laser excitation and ≥8 color measurements. The specific adaptations required in the instrument set-up to enable them to acquire the standardized 8-color EuroFlow protocols are described here. Overall, all 14 instruments can be fitted with similar violet, blue and red lasers for simultaneous measurements of ≥8 fluorescent dyes. Since individual instruments differ both on their dynamic range (scale) and emission filters, it is not accurate to simply recalculate the target values to different scale, but adjustment of PMT voltages to a given emission filter and fluorochrome, is essential. For this purpose, EuroFlow has developed an approach using Type IIB (spectrally matching) particles to set-up standardized and fully comparable fluorescence measurements, in instruments from different manufacturers, as demonstrated here for the FACSCanto II, and Navios and MACSQuant flow cytometers. Data acquired after such adjustment on any of the tested cytometry platforms could be fully superimposed and therefore analyzed together. The proposed approach can be used to derive target values for any combination of spectrally distinct fluorochromes and any distinct emission filter of any new flow cytometry platform, which enables the measurement of the 8-color EuroFlow panels in a standardized way, by creating superimposable datafiles.
Identifiants
pubmed: 29154914
pii: S0022-1759(17)30139-4
doi: 10.1016/j.jim.2017.11.007
pii:
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
112388Informations de copyright
Copyright © 2017. Published by Elsevier B.V.