Percutaneous Dilatational Tracheostomy Using Tube Exchanger.
Journal
Anesthesia and analgesia
ISSN: 1526-7598
Titre abrégé: Anesth Analg
Pays: United States
ID NLM: 1310650
Informations de publication
Date de publication:
08 2019
08 2019
Historique:
pubmed:
16
3
2018
medline:
6
2
2020
entrez:
16
3
2018
Statut:
ppublish
Résumé
We describe a modified technique for percutaneous dilatational tracheostomy using a 15F tube exchanger or Eschmann catheter. A retrospective review of 1180 procedures using this modified technique demonstrated it to be effective with a failure rate of only 0.25% (3 patients). Moreover, it provides an additional safeguard with the ability to rapidly reintroduce the endotracheal tube into the trachea guided by the exchange catheter in the event of accidental extubation during the procedure. This technique needs no additional special devices or equipment (eg, a bronchoscope). However, a prospective study is needed to better define its complication rate.
Identifiants
pubmed: 29543641
doi: 10.1213/ANE.0000000000003321
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM