Use of the Apollo detachable-tip microcatheter for endovascular embolization of arteriovenous malformations and arteriovenous fistulas.
Adolescent
Adult
Aged
Aged, 80 and over
Arteriovenous Fistula
/ therapy
Catheterization
Catheters
Child
Dimethyl Sulfoxide
Embolization, Therapeutic
/ adverse effects
Female
Humans
Intracranial Arteriovenous Malformations
/ therapy
Intracranial Hemorrhages
/ therapy
Male
Middle Aged
Polyvinyls
Retrospective Studies
Treatment Outcome
Young Adult
AVF = arteriovenous fistula
AVM = arteriovenous malformation
Apollo microcatheter
DMSO = dimethyl sulfoxide
EVOH = ethylene vinyl alcohol
NBCA = N-butyl cyanoacrylate
arteriovenous fistula
arteriovenous malformation
detachable-tip microcatheter
embolization
interventional neurosurgery
oncology
vascular disorders
Journal
Journal of neurosurgery
ISSN: 1933-0693
Titre abrégé: J Neurosurg
Pays: United States
ID NLM: 0253357
Informations de publication
Date de publication:
01 03 2019
01 03 2019
Historique:
received:
14
02
2017
accepted:
11
09
2017
pubmed:
24
3
2018
medline:
19
10
2019
entrez:
24
3
2018
Statut:
ppublish
Résumé
Liquid embolic agents have revolutionized endovascular management of arteriovenous malformations (AVMs) and arteriovenous fistulas (AVFs). Nonetheless, since 2005, the US FDA has received more than 100 reports of microcatheter breakage or entrapment related to Onyx embolization, including 9 deaths. In 2014, the Apollo detachable-tip microcatheter became the first of its kind available in the US. Since then, few reports on its safety have been published. The authors conducted a retrospective review of endovascular cases by searching the patient databases at 2 tertiary cerebrovascular centers (Barrow Neurological Institute and University of Pittsburgh Medical Center). Patients who underwent endovascular embolization of an AVM or AVF using the Apollo microcatheter were identified. Patient demographics and lesion characteristics were collected. The authors analyzed Apollo-specific endovascular variables, such as number of microcatheterizations, sessions, and pedicles embolized; microcatheter tip detachment status; obliteration rate; and endovascular- and microcatheter-related morbidity and mortality. From July 2014 to October 2016, a total of 177 embolizations using the Apollo microcatheter were performed in 61 patients (mean age 40.3 years). The most frequent presentation was hemorrhage (22/61, 36.1%). Most lesions were AVMs (51/61, 83.6%; mean diameter 30.6 mm). The mean Spetzler-Martin grade was 2.4. Thirty-nine (76.5%) of 51 patients with AVMs underwent resection. Microcatheterization was successful in 172 pedicles. Most patients (50/61, 82%) underwent a single embolization session. The mean number of pedicles per session was 2.5 (range 1-7). Onyx-18 was used in 103 (59.9%), N-butyl cyanoacrylate (NBCA) in 44 (25.6%), and Onyx-34 in 25 (14.5%) of the 172 embolizations. In 45.9% (28/61) of the patients, lesion obliteration of 75% or greater was achieved. Tip detachment occurred in 19.2% (33/172) of microcatheters. Fifty-three (86.9%) of the 61 patients who underwent embolization with the Apollo microcatheter had good functional outcomes (modified Rankin Scale score 0-2). No unintended microcatheter fractures or related morbidity was observed. One patient died of intraprocedural complications unrelated to microcatheter selection. In the univariate analysis, microcatheter tip detachment (p = 0.12), single embolized pedicles (p = 0.12), and smaller AVM nidus diameter (p = 0.17) correlated positively with high obliteration rates (> 90%). In the multivariate analysis, microcatheter tip detachment was the only independent variable associated with high obliteration rates (OR 9.5; p = 0.03). The use of the Apollo detachable-tip microcatheter for embolization of AVMs and AVFs is associated with high rates of successful catheterization and obliteration and low rates of morbidity and mortality. The microcatheter was retrieved in all cases, even after prolonged injections in distal branch pedicles, often with significant reflux. This study represents the largest case series on the application of the Apollo microcatheter for neurointerventional procedures.
Identifiants
pubmed: 29570006
doi: 10.3171/2017.9.JNS17397
doi:
Substances chimiques
Onyx copolymer
0
Polyvinyls
0
Dimethyl Sulfoxide
YOW8V9698H
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM