Effect of Light-Cured Resin Cement Application on Translucency of Ceramic Veneers and Light Transmission of LED Polymerization Units.


Journal

Journal of prosthodontics : official journal of the American College of Prosthodontists
ISSN: 1532-849X
Titre abrégé: J Prosthodont
Pays: United States
ID NLM: 9301275

Informations de publication

Date de publication:
Jan 2019
Historique:
accepted: 07 03 2018
pubmed: 2 6 2018
medline: 8 6 2019
entrez: 2 6 2018
Statut: ppublish

Résumé

To evaluate the effect of light-cured resin cement application based on etching and silanization on the translucent property of ceramic veneers in different thicknesses, testing the hypothesis that the surface treatment and subsequent resin cement application could influence the translucency of ceramic veneers. The relationship between translucency of ceramic veneers and light transmission irradiated by LED polymerization units was also determined. 40 specimens (10 mm diameter) were fabricated from IPS e.max Press HT A2 ceramic ingots, and polished to 0.3 ± 0.01 mm, 0.5 ± 0.01 mm, 0.7 ± 0.01 mm, 1.0 ± 0.01 mm, and 1.5 ± 0.01 mm thick (n = 8/group). One surface of each disc was etched with HF acid, silanized with Monobond-S, and applied with a light-cured resin cement (Variolink N Transparent Base). Before and after the above procedure, the total luminous transmittance (τ) of all specimens was assessed by a spectrophotometer in a wavelength range of 380-780 nm. A handheld radiometer was used to measure the light intensity irradiated by three LED polymerization units. Light transmission (LT) through ceramic specimens after resin cement application was calculated. Data were statistically analyzed using two-way ANOVA (p = 0.05) and Tukey's test. The correlation between translucency (τ) of ceramic veneers after resin cement application and light transmission (LT) of curing units was statistically evaluated using Spearman correlation test (p = 0.05). With the increase of ceramic thickness, the transmittance decreased significantly (p < 0.05). For the 0.3-mm, 0.5-mm, and 0.7-mm-thick groups, the transmittance of ceramic specimens was statistically significantly lower after resin cement application (p < 0.05). The r value of Bluephase C8 was 0.988, 0.977 for Bluphase, and 0.883 for Bluephase 20i, indicating that the light transmission (LT%) was positively correlated to the translucency of ceramic veneers, regardless of the type of curing units. After the light-cured resin cement application based on etching and silanization, the ceramic veneers (less than 0.7-mm thick) were less translucent, and the translucency decreased when the thickness increased. Because of the lower translucency of ceramic veneers, the light intensity of LED units transmitted to resin layer would decrease when curing.

Identifiants

pubmed: 29855119
doi: 10.1111/jopr.12910
doi:

Substances chimiques

Dental Materials 0
Resin Cements 0

Types de publication

Journal Article

Langues

eng

Pagination

e376-e382

Informations de copyright

© 2018 by the American College of Prosthodontists.

Auteurs

Lei Zhang (L)

Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.

Xiao Ping Luo (XP)

Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.

Ren Xiang Tan (RX)

State Key Laboratory of Pharmaceutical Biotechnology, Institute of Functional Biomolecules, Nanjing University, Nanjing, China.
State Key Laboratory Cultivation Base for TCM Quality and Efficacy, Nanjing University of Chinese Medicine, Nanjing, China.

Articles similaires

Hemiarthroplasty in young patients.

Hazimah Mahmud, Dong Wang, Andra Topan-Rat et al.
1.00
Humans Male Hemiarthroplasty Middle Aged Aged
Fragaria Light Plant Leaves Osmosis Stress, Physiological
1.00
Sudan Archaeology Humans History, Ancient Animals
Biomass Lignin Wood Populus Microscopy, Electron, Scanning

Classifications MeSH