Dual-room CT with a sliding gantry for intraoperative imaging: feasibility and workflow analysis of an interdisciplinary concept.


Journal

International journal of computer assisted radiology and surgery
ISSN: 1861-6429
Titre abrégé: Int J Comput Assist Radiol Surg
Pays: Germany
ID NLM: 101499225

Informations de publication

Date de publication:
Feb 2019
Historique:
received: 07 03 2018
accepted: 12 06 2018
pubmed: 24 6 2018
medline: 9 4 2019
entrez: 24 6 2018
Statut: ppublish

Résumé

Currently, intraoperative computed tomography (iCT) is a scarcely used technique in neurosurgery. It remains unclear whether this phenomenon is explained by unfavorable iCT-related workflows and/or a limited number of indications. We here analyzed workflows of an installed dual-room iCT (DR-iCT) as compared to surgical procedures lacking iCT. We compared infection rates, utilizations rates, and the spectrum of indications of DR-iCT with that of a previously used single-room iCT. The study refers to a consecutive series of patients undergoing either single-room iCT (January 2014-August 2014) or DR-iCT (September 2014-July 2016). A further group undergoing surgery without iCT in the interconnected operating rooms represents the reference group. Workflow measurements and infection rates were calculated. Indications for iCT and utilization rates were compared for each of the devices. CT image quality was rated. Application of DR-iCT led to a broader use of this technique as compared to the single-room device, which concerned in particular stereotactic neurosurgery. Accordingly, iCT utilization rates significantly increased (up to 50.8 ± 4.6 surgeries per month, p < 0.001). Workflow was slightly prolonged in case of DR-iCT imaging; the difference, however, was not statistically significant. Infections rates were low (range 0.0-0.17 infections per month) and not influenced by the utilization rate. Image quality of the DR-iCT was classified as very good in 34/43 evaluated microsurgical patients. The use of DR-iCT enhances utilization rates with a broader field of indications for intraoperative imaging. Workflow measurements are not significantly prolonged. The technology is safe, and the imaging quality of modern devices can be expected to be good.

Identifiants

pubmed: 29934791
doi: 10.1007/s11548-018-1812-9
pii: 10.1007/s11548-018-1812-9
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

397-407

Références

Acta Neurochir (Wien). 1991;111(1-2):61-3
pubmed: 1927626
Acta Neurochir Suppl. 2011;109:163-7
pubmed: 20960337
J Neurosurg. 2016 May;124(5):1319-27
pubmed: 26566206
J Neurosurg Pediatr. 2017 Jan;19(1):77-84
pubmed: 27791707
Photodiagnosis Photodyn Ther. 2016 Dec;16:35-43
pubmed: 27491856
Curr Med Res Opin. 2017 Apr;33(4):621-630
pubmed: 28008781
Br J Neurosurg. 2017 Feb;31(1):10-15
pubmed: 27905216
J Neurosurg. 2010 Apr;112(4):722-8
pubmed: 19817544
J Oral Maxillofac Surg. 2018 May;76(5):1016-1025
pubmed: 29304328
Neurosurg Clin N Am. 2017 Oct;28(4):453-464
pubmed: 28917275
Neurol Res. 2006 Jul;28(5):482-7
pubmed: 16808876
J Neurosci Rural Pract. 2016 Oct-Dec;7(4):598-602
pubmed: 27695249
Neurosurgery. 2005;56(1):130-7; discussion 138
pubmed: 15617595
World Neurosurg. 2016 Aug;92:255-263
pubmed: 27178235
World Neurosurg. 2016 Sep;93:183-90
pubmed: 27319315
Semin Thorac Cardiovasc Surg. 2018 Spring;30(1):96-101
pubmed: 28935510
Acta Neurochir (Wien). 2012 Oct;154(10):1861-8
pubmed: 22790837
Surg Neurol. 1982 May;17(5):376-82
pubmed: 6283689
Neurosurgery. 1998 Jun;42(6):1304-10; discussion 1310-1
pubmed: 9632189
Neurosurgery. 2009 May;64(5 Suppl 2):231-9; discussion 239-40
pubmed: 19404103
Spine (Phila Pa 1976). 2009 Dec 15;34(26):2919-26
pubmed: 20010400
Stereotact Funct Neurosurg. 1996;66(1-3):58-64
pubmed: 8938933
J Neurosurg. 2009 Dec;111(6):1168-74
pubmed: 19301958
Cochlear Implants Int. 2018 May;19(3):170-179
pubmed: 29188758
World Neurosurg. 2017 Jul;103:275-282
pubmed: 28363833
Cochrane Database Syst Rev. 2018 Jan 22;1:CD012788
pubmed: 29355914
Neurosurgery. 1997 Oct;41(4):831-42; discussion 842-5
pubmed: 9316044
Neurosurgery. 2016 Dec;79(6):889-894
pubmed: 27465846
Oper Neurosurg (Hagerstown). 2017 Dec 1;13(6):739-745
pubmed: 29186602

Auteurs

Markus Lenski (M)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany. markus.lenski@med.uni-muenchen.de.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany. markus.lenski@med.uni-muenchen.de.

Johann Hofereiter (J)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Nicole Terpolilli (N)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Torleif Sandner (T)

Department of Neuroradiology, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Stefan Zausinger (S)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Jörg-Christian Tonn (JC)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Friedrich-Wilhelm Kreth (FW)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Christian Schichor (C)

Neurochirurgische Klinik und Poliklinik, Department of Neurosurgery, Klinikum der Universität München, Campus Großhadern, Marchioninistraße 15, 81377, Munich, Germany.
German Cancer Consortium, Partner Site Munich, German Cancer Research Center, Heidelberg, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH