Effect of I-scan Electronic Chromoendoscopy on Detection of Adenomas During Colonoscopy.


Journal

Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association
ISSN: 1542-7714
Titre abrégé: Clin Gastroenterol Hepatol
Pays: United States
ID NLM: 101160775

Informations de publication

Date de publication:
03 2019
Historique:
received: 08 03 2018
revised: 12 06 2018
accepted: 13 06 2018
pubmed: 24 6 2018
medline: 3 7 2020
entrez: 24 6 2018
Statut: ppublish

Résumé

I-scan is an electronic chromoendoscopy technology that improves resolution of epithelial and mucosal surfaces and vessels. We performed a randomized controlled trial to compare detection of adenomas by i-scan vs standard high-definition white-light (HDWL) colonoscopy. From February 1 through December 31, 2017, 740 outpatients (50-75 years old) undergoing screening and surveillance for colorectal neoplasia were randomly assigned to groups that received colonoscopies with i-scan 1 (surface and contrast enhancement) or HDWL. When lesions and polyps were detected, endoscopists could switch between i-scan 1 and HDWL imaging to confirm their finding; polyps were collected and analyzed by histology. The primary outcome was adenoma detection rate (ADR, proportion of subjects with at least 1 adenoma of any size); secondary outcomes included detection of sessile serrated polyps and neoplasias, along with location, size, and morphology of polyps. We performed intent to treat and per-protocol analyses (on 357 patients evaluated by i-scan and 358 evaluated by HDWL colonoscopy) to assess the primary and secondary outcomes. There were no differences in baseline characteristics between the groups. In the intent to treat analysis, the ADR was significantly higher in the i-scan 1 group (47.2%) than in the HDWL colonoscopy group (37.7%) (P = .01). In the per-protocol analysis, the ADR in the i-scan 1 group (47.6%) was also significantly higher than in the HDWL group (37.2%) (P = .005), but this effect was not consistent among all endoscopists. There was no difference between groups in detection of sessile serrated polyps. However, the rate of neoplasia detection was significantly higher in the i-scan 1 group (56.4%) than in the than the HDWL group (46.1%) (P = .005). In secondary analyses, the increase in ADR was associated with improved detection of diminutive flat adenomas in the right colon. In a prospective randomized trial, higher proportions of patients with adenomas were identified in a group that underwent colonoscopy with i-scan 1 than in a group evaluated by HDWL colonoscopy. This effect was mainly due to improved detection of diminutive, flat right sided adenomas. I-scan 1 technology may benefit some endoscopists. ClinicalTrials.gov no: NCT02811419.

Sections du résumé

BACKGROUND & AIMS
I-scan is an electronic chromoendoscopy technology that improves resolution of epithelial and mucosal surfaces and vessels. We performed a randomized controlled trial to compare detection of adenomas by i-scan vs standard high-definition white-light (HDWL) colonoscopy.
METHODS
From February 1 through December 31, 2017, 740 outpatients (50-75 years old) undergoing screening and surveillance for colorectal neoplasia were randomly assigned to groups that received colonoscopies with i-scan 1 (surface and contrast enhancement) or HDWL. When lesions and polyps were detected, endoscopists could switch between i-scan 1 and HDWL imaging to confirm their finding; polyps were collected and analyzed by histology. The primary outcome was adenoma detection rate (ADR, proportion of subjects with at least 1 adenoma of any size); secondary outcomes included detection of sessile serrated polyps and neoplasias, along with location, size, and morphology of polyps. We performed intent to treat and per-protocol analyses (on 357 patients evaluated by i-scan and 358 evaluated by HDWL colonoscopy) to assess the primary and secondary outcomes.
RESULTS
There were no differences in baseline characteristics between the groups. In the intent to treat analysis, the ADR was significantly higher in the i-scan 1 group (47.2%) than in the HDWL colonoscopy group (37.7%) (P = .01). In the per-protocol analysis, the ADR in the i-scan 1 group (47.6%) was also significantly higher than in the HDWL group (37.2%) (P = .005), but this effect was not consistent among all endoscopists. There was no difference between groups in detection of sessile serrated polyps. However, the rate of neoplasia detection was significantly higher in the i-scan 1 group (56.4%) than in the than the HDWL group (46.1%) (P = .005). In secondary analyses, the increase in ADR was associated with improved detection of diminutive flat adenomas in the right colon.
CONCLUSION
In a prospective randomized trial, higher proportions of patients with adenomas were identified in a group that underwent colonoscopy with i-scan 1 than in a group evaluated by HDWL colonoscopy. This effect was mainly due to improved detection of diminutive, flat right sided adenomas. I-scan 1 technology may benefit some endoscopists. ClinicalTrials.gov no: NCT02811419.

Identifiants

pubmed: 29935326
pii: S1542-3565(18)30634-7
doi: 10.1016/j.cgh.2018.06.024
pii:
doi:

Banques de données

ClinicalTrials.gov
['NCT02811419']

Types de publication

Comparative Study Evaluation Study Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

701-708.e1

Subventions

Organisme : NCI NIH HHS
ID : K07 CA212057
Pays : United States

Informations de copyright

Copyright © 2019 AGA Institute. Published by Elsevier Inc. All rights reserved.

Auteurs

Trilokesh D Kidambi (TD)

Division of Gastroenterology, City of Hope National Medical Center, Duarte, California.

Jonathan P Terdiman (JP)

Division of Gastroenterology, University of California, San Francisco, San Francisco, California.

Najwa El-Nachef (N)

Division of Gastroenterology, University of California, San Francisco, San Francisco, California.

Aparajita Singh (A)

Division of Gastroenterology, University of California, San Francisco, San Francisco, California.

Michael G Kattah (MG)

Division of Research, Kaiser Permanente, Oakland, California.

Jeffrey K Lee (JK)

Division of Research, Kaiser Permanente, Oakland, California; Department of Gastroenterology, Kaiser Permanente San Francisco Medical Center, San Francisco, California. Electronic address: jeffrey.k.lee@kp.org.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH