Effect of I-scan Electronic Chromoendoscopy on Detection of Adenomas During Colonoscopy.
Colon Cancer Prevention
Early Detection
Imaging Technology
Neoplasm
Journal
Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association
ISSN: 1542-7714
Titre abrégé: Clin Gastroenterol Hepatol
Pays: United States
ID NLM: 101160775
Informations de publication
Date de publication:
03 2019
03 2019
Historique:
received:
08
03
2018
revised:
12
06
2018
accepted:
13
06
2018
pubmed:
24
6
2018
medline:
3
7
2020
entrez:
24
6
2018
Statut:
ppublish
Résumé
I-scan is an electronic chromoendoscopy technology that improves resolution of epithelial and mucosal surfaces and vessels. We performed a randomized controlled trial to compare detection of adenomas by i-scan vs standard high-definition white-light (HDWL) colonoscopy. From February 1 through December 31, 2017, 740 outpatients (50-75 years old) undergoing screening and surveillance for colorectal neoplasia were randomly assigned to groups that received colonoscopies with i-scan 1 (surface and contrast enhancement) or HDWL. When lesions and polyps were detected, endoscopists could switch between i-scan 1 and HDWL imaging to confirm their finding; polyps were collected and analyzed by histology. The primary outcome was adenoma detection rate (ADR, proportion of subjects with at least 1 adenoma of any size); secondary outcomes included detection of sessile serrated polyps and neoplasias, along with location, size, and morphology of polyps. We performed intent to treat and per-protocol analyses (on 357 patients evaluated by i-scan and 358 evaluated by HDWL colonoscopy) to assess the primary and secondary outcomes. There were no differences in baseline characteristics between the groups. In the intent to treat analysis, the ADR was significantly higher in the i-scan 1 group (47.2%) than in the HDWL colonoscopy group (37.7%) (P = .01). In the per-protocol analysis, the ADR in the i-scan 1 group (47.6%) was also significantly higher than in the HDWL group (37.2%) (P = .005), but this effect was not consistent among all endoscopists. There was no difference between groups in detection of sessile serrated polyps. However, the rate of neoplasia detection was significantly higher in the i-scan 1 group (56.4%) than in the than the HDWL group (46.1%) (P = .005). In secondary analyses, the increase in ADR was associated with improved detection of diminutive flat adenomas in the right colon. In a prospective randomized trial, higher proportions of patients with adenomas were identified in a group that underwent colonoscopy with i-scan 1 than in a group evaluated by HDWL colonoscopy. This effect was mainly due to improved detection of diminutive, flat right sided adenomas. I-scan 1 technology may benefit some endoscopists. ClinicalTrials.gov no: NCT02811419.
Sections du résumé
BACKGROUND & AIMS
I-scan is an electronic chromoendoscopy technology that improves resolution of epithelial and mucosal surfaces and vessels. We performed a randomized controlled trial to compare detection of adenomas by i-scan vs standard high-definition white-light (HDWL) colonoscopy.
METHODS
From February 1 through December 31, 2017, 740 outpatients (50-75 years old) undergoing screening and surveillance for colorectal neoplasia were randomly assigned to groups that received colonoscopies with i-scan 1 (surface and contrast enhancement) or HDWL. When lesions and polyps were detected, endoscopists could switch between i-scan 1 and HDWL imaging to confirm their finding; polyps were collected and analyzed by histology. The primary outcome was adenoma detection rate (ADR, proportion of subjects with at least 1 adenoma of any size); secondary outcomes included detection of sessile serrated polyps and neoplasias, along with location, size, and morphology of polyps. We performed intent to treat and per-protocol analyses (on 357 patients evaluated by i-scan and 358 evaluated by HDWL colonoscopy) to assess the primary and secondary outcomes.
RESULTS
There were no differences in baseline characteristics between the groups. In the intent to treat analysis, the ADR was significantly higher in the i-scan 1 group (47.2%) than in the HDWL colonoscopy group (37.7%) (P = .01). In the per-protocol analysis, the ADR in the i-scan 1 group (47.6%) was also significantly higher than in the HDWL group (37.2%) (P = .005), but this effect was not consistent among all endoscopists. There was no difference between groups in detection of sessile serrated polyps. However, the rate of neoplasia detection was significantly higher in the i-scan 1 group (56.4%) than in the than the HDWL group (46.1%) (P = .005). In secondary analyses, the increase in ADR was associated with improved detection of diminutive flat adenomas in the right colon.
CONCLUSION
In a prospective randomized trial, higher proportions of patients with adenomas were identified in a group that underwent colonoscopy with i-scan 1 than in a group evaluated by HDWL colonoscopy. This effect was mainly due to improved detection of diminutive, flat right sided adenomas. I-scan 1 technology may benefit some endoscopists. ClinicalTrials.gov no: NCT02811419.
Identifiants
pubmed: 29935326
pii: S1542-3565(18)30634-7
doi: 10.1016/j.cgh.2018.06.024
pii:
doi:
Banques de données
ClinicalTrials.gov
['NCT02811419']
Types de publication
Comparative Study
Evaluation Study
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
701-708.e1Subventions
Organisme : NCI NIH HHS
ID : K07 CA212057
Pays : United States
Informations de copyright
Copyright © 2019 AGA Institute. Published by Elsevier Inc. All rights reserved.