Mapping the noise in a Greek general hospital.

Acoustics Indoor environmental quality Occupational safety and health Patient care

Journal

The Science of the total environment
ISSN: 1879-1026
Titre abrégé: Sci Total Environ
Pays: Netherlands
ID NLM: 0330500

Informations de publication

Date de publication:
01 Jan 2019
Historique:
received: 09 05 2018
revised: 18 07 2018
accepted: 22 07 2018
pubmed: 2 8 2018
medline: 4 4 2019
entrez: 2 8 2018
Statut: ppublish

Résumé

Sound pressure levels were monitored in a general hospital, in Greece, at ten indoor locations and at three outdoor locations, in the yard of the building. The selected indoor locations are representative of distinct activities that are common in every hospital, such as the emergency department, patient wards and several supporting services, like washing the clothes or the dishes. Noise levels were highly variable in each monitoring location and depended on the activities in the room, such as conversations, medical equipment in use, analytical devices or other machinery in operation. The highest noise levels that were recorded were in the blood donation unit and in the laundry room (the L

Identifiants

pubmed: 30067962
pii: S0048-9697(18)32810-9
doi: 10.1016/j.scitotenv.2018.07.315
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

923-929

Informations de copyright

Copyright © 2018 Elsevier B.V. All rights reserved.

Auteurs

G Loupa (G)

Laboratory of Atmospheric Pollution and of Control Engineering of Atmospheric Pollutants, Faculty of Engineering, Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi, Greece. Electronic address: gloupa@env.duth.gr.

A Katikaridis (A)

Laboratory of Atmospheric Pollution and of Control Engineering of Atmospheric Pollutants, Faculty of Engineering, Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi, Greece.

D Karali (D)

Laboratory of Atmospheric Pollution and of Control Engineering of Atmospheric Pollutants, Faculty of Engineering, Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi, Greece.

S Rapsomanikis (S)

Laboratory of Atmospheric Pollution and of Control Engineering of Atmospheric Pollutants, Faculty of Engineering, Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi, Greece.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH