Comparison of polyetheretherketone versus silicon nitride intervertebral spinal spacers in a caprine model.
caprine animal model
interbody cage
osseointegration
polyetheretherketone
silicon nitride
Journal
Journal of biomedical materials research. Part B, Applied biomaterials
ISSN: 1552-4981
Titre abrégé: J Biomed Mater Res B Appl Biomater
Pays: United States
ID NLM: 101234238
Informations de publication
Date de publication:
04 2019
04 2019
Historique:
received:
04
10
2017
revised:
22
04
2018
accepted:
29
04
2018
pubmed:
10
8
2018
medline:
7
7
2020
entrez:
10
8
2018
Statut:
ppublish
Résumé
Polyetheretherketone (PEEK) is commonly used as a spinal spacer for intervertebral fusion surgery. Unfortunately, PEEK is bioinert and does not effectively osseointegrate into living bone. In contrast, comparable spacers made of silicon nitride (Si