[Vitrectomy and iOCT-assisted inverted ILM flap technique in patients with full thickness macular holes].
Vitrektomie mit iOCT-assistierter invertierter ILM-Flap-Technik bei großen Makulaforamina.
Intraoperative OCT
Inverted ILM flap
Macular hole surgery
Photoreceptor outer segment
Spectral domain OCT
Transconjunctival sutureless pars plana vitrectomy
Journal
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft
ISSN: 1433-0423
Titre abrégé: Ophthalmologe
Pays: Germany
ID NLM: 9206148
Informations de publication
Date de publication:
Jul 2019
Jul 2019
Historique:
pubmed:
15
8
2018
medline:
28
7
2019
entrez:
15
8
2018
Statut:
ppublish
Résumé
In large full thickness macular holes (FTMH) the closure rate after vitrectomy and conventional internal limiting membrane (ILM) peeling is less than 90%. The aim of this study was to examine the visual acuity and anatomical success rate with high-resolution optical coherence tomography (OCT) after transconjunctival sutureless 23-gauge pars plana vitrectomy as well as intraoperative OCT (iOCT) and Brilliant Peel (BP)-assisted ILM peeling using the inverted ILM flap technique in patients with large FTMHs. In this retrospective study 25 eyes of 25 consecutive patients with large FTMH were treated by 23-G vitrectomy with BP and iOCT-assisted ILM peeling using the inverted ILM flap technique followed by gas tamponade. In all patients best corrected visual acuity (BCVA) and the maximum diameter, base and height of the FTMH as well as intraretinal alterations were measured preoperatively using high-resolution spectral domain OCT (SD-OCT, Spectralis, Heidelberg Engineering, Germany). The BCVA was measured after 1, 3, and 6 months. Additionally, the closure rate and the microstructural integrity of the outer retinal layers, e.g. external limiting membrane (ELM), ellipsoid zone und photoreceptor outer segment (OS) were registered in the SD-OCT and correlated with the results of BCVA after macular hole surgery. In all surgical procedures with the inverted ILM flap technique the application of iOCT enabled a good visualization and a controlled positioning of the ILM flaps. At baseline mean BCVA was 0.2 (0.7 logMAR) and improved significantly after 1, 3 und 6 months to 0.4 (0.4 logMAR), 0.5 (0.3 logMAR) and 0.63 (0.2 logMAR), respectively. The closure rate of the FTMHs was 100%. Microstructural integrity of the outer retinal layers was evaluated semiquantitatively and showed good correlation with BCVA. Vitrectomy with BP and iOCT-assisted ILM peeling using the inverted ILM flap technique in patients with large FTMH is a very controlled and safe microsurgical strategy and shows good functional and anatomical results. The morphology of the FTMH, the ILM flap and the position of the inverted ILM flap under air was well visualized by IOCT. The microstructural integrity of the outer retinal layers is displayed in detail on SD-OCT and represents an important predictive parameter for BCVA after macular hole surgery.
Sections du résumé
BACKGROUND
BACKGROUND
In large full thickness macular holes (FTMH) the closure rate after vitrectomy and conventional internal limiting membrane (ILM) peeling is less than 90%. The aim of this study was to examine the visual acuity and anatomical success rate with high-resolution optical coherence tomography (OCT) after transconjunctival sutureless 23-gauge pars plana vitrectomy as well as intraoperative OCT (iOCT) and Brilliant Peel (BP)-assisted ILM peeling using the inverted ILM flap technique in patients with large FTMHs.
METHOD
METHODS
In this retrospective study 25 eyes of 25 consecutive patients with large FTMH were treated by 23-G vitrectomy with BP and iOCT-assisted ILM peeling using the inverted ILM flap technique followed by gas tamponade. In all patients best corrected visual acuity (BCVA) and the maximum diameter, base and height of the FTMH as well as intraretinal alterations were measured preoperatively using high-resolution spectral domain OCT (SD-OCT, Spectralis, Heidelberg Engineering, Germany). The BCVA was measured after 1, 3, and 6 months. Additionally, the closure rate and the microstructural integrity of the outer retinal layers, e.g. external limiting membrane (ELM), ellipsoid zone und photoreceptor outer segment (OS) were registered in the SD-OCT and correlated with the results of BCVA after macular hole surgery.
RESULTS
RESULTS
In all surgical procedures with the inverted ILM flap technique the application of iOCT enabled a good visualization and a controlled positioning of the ILM flaps. At baseline mean BCVA was 0.2 (0.7 logMAR) and improved significantly after 1, 3 und 6 months to 0.4 (0.4 logMAR), 0.5 (0.3 logMAR) and 0.63 (0.2 logMAR), respectively. The closure rate of the FTMHs was 100%. Microstructural integrity of the outer retinal layers was evaluated semiquantitatively and showed good correlation with BCVA.
CONCLUSION
CONCLUSIONS
Vitrectomy with BP and iOCT-assisted ILM peeling using the inverted ILM flap technique in patients with large FTMH is a very controlled and safe microsurgical strategy and shows good functional and anatomical results. The morphology of the FTMH, the ILM flap and the position of the inverted ILM flap under air was well visualized by IOCT. The microstructural integrity of the outer retinal layers is displayed in detail on SD-OCT and represents an important predictive parameter for BCVA after macular hole surgery.
Identifiants
pubmed: 30105564
doi: 10.1007/s00347-018-0769-y
pii: 10.1007/s00347-018-0769-y
doi:
Types de publication
Journal Article
Langues
ger
Pagination
617-624Références
Arch Ophthalmol. 2002 Jan;120(1):29-35
pubmed: 11786054
Am J Ophthalmol. 2002 Dec;134(6):836-41
pubmed: 12470751
Arch Ophthalmol. 1991 May;109(5):654-9
pubmed: 2025167
Ophthalmology. 2010 Oct;117(10):2018-25
pubmed: 20541263
Ophthalmic Surg Lasers Imaging. 2012 May-Jun;43(3):184-9
pubmed: 22320413
Am J Ophthalmol. 2013 Jul;156(1):125-131.e1
pubmed: 23622567
Klin Monbl Augenheilkd. 2013 Jul;230(7):701-6
pubmed: 23775289
Retina. 2014 Feb;34(2):213-21
pubmed: 23860560
Ophthalmologica. 2013;230 Suppl 2:51-8
pubmed: 24022719
Klin Monbl Augenheilkd. 2014 Jan;231(1):54-60
pubmed: 24104961
Am J Ophthalmol. 2014 Apr;157(4):861-869.e1
pubmed: 24418265
Retina. 2014 Dec;34(12):2444-50
pubmed: 25062441
Invest Ophthalmol Vis Sci. 2014 Dec 18;56(2):1141-6
pubmed: 25525173
J Ophthalmol. 2015;2015:809640
pubmed: 25821592
Retina. 2015 Sep;35(9):1844-50
pubmed: 25946691
Ophthalmologe. 2016 Aug;113(8):656-62
pubmed: 27369734
Ophthalmologe. 2017 Feb;114(2):148-154
pubmed: 27444007
Clin Ophthalmol. 2016 Dec 16;11:9-14
pubmed: 28031697
Retina. 2017 Oct;37(10):1923-1930
pubmed: 28067723
Graefes Arch Clin Exp Ophthalmol. 2017 Jun;255(6):1073-1078
pubmed: 28161828
Klin Monbl Augenheilkd. 2018 Sep;235(9):1028-1034
pubmed: 28599336
Invest Ophthalmol Vis Sci. 2017 Jul 1;58(9):3440-3444
pubmed: 28692739
Invest Ophthalmol Vis Sci. 2017 Sep 1;58(11):4847-4855
pubmed: 28973331
BMC Ophthalmol. 2017 Nov 28;17(1):219
pubmed: 29179705
Retina. 2018 Sep;38 Suppl 1:S73-S78
pubmed: 29232338
Graefes Arch Clin Exp Ophthalmol. 2018 Jun;256(6):1041-1049
pubmed: 29532170
Acta Ophthalmol. 2018 Dec;96(8):e904-e910
pubmed: 29671948