Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT.
Adenocarcinoma
/ diagnostic imaging
Aged
Aged, 80 and over
Carcinoma, Pancreatic Ductal
/ diagnostic imaging
Contrast Media
Female
Humans
Iodine
Male
Middle Aged
Multidetector Computed Tomography
/ methods
Pancreatic Neoplasms
/ diagnostic imaging
Prospective Studies
Radiographic Image Enhancement
/ methods
Radiography, Dual-Energy Scanned Projection
Pancreatic ductal adenocarcinoma
Rapid kV-switching dual-energy computed tomography
İodine concentration
Journal
Abdominal radiology (New York)
ISSN: 2366-0058
Titre abrégé: Abdom Radiol (NY)
Pays: United States
ID NLM: 101674571
Informations de publication
Date de publication:
02 2019
02 2019
Historique:
pubmed:
30
8
2018
medline:
31
3
2020
entrez:
30
8
2018
Statut:
ppublish
Résumé
Multidetector computed tomography (MDCT) is used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases. Tumor detection can be improved using rapid kV-switching dual-energy CT (rsDECT) and iodine maps. Our aim this study is to evaluate tumor conspicuity in PDAC cases using rsDECT and iodine maps. Ninety cases with PDAC were evaluated rsDECT. Tumor contrast (HU) differences, tumor size, CNR (contrast-noise ratio), and noise were measured at 70 keV, individual CNR-energy level, and 45 keV, respectively. Quantitative differences in contrast gain ∆70-CNR and ∆CNR-45 were compared. On iodine maps, the iodine concentration measured in the tumor and parenchyma was normalized to the aorta as normalized iodine concentration (NIC) and compared. The median optimized viewing energy level was 51 keV. The mean ± SD tumor contrast values were 62 ± 20, 115 ± 48, and 152 ± 48 HU (p < 0.001); the largest axial diameters were 36.6 ± 5.1, 37.9 ± 4.2, and 38.3 ± 3.7 mm (p = 0.015); the CNRs were 1.83 ± 0.72, 3.37 ± 0.93, and 2.36 ± 0.56; and the image noise levels were 23.7 ± 6.8, 39.3 ± 11.6, and 59.5 ± 17.2 (p < 0.001) (p < 0.001) for 70 keV, optimized energy level, and 45 keV, respectively. The mean ± SD contrast gain ∆70-CNR was 63 ± 12; and ∆CNR-45 was 31 ± 26 HU (p < 0.001). NIC The use of low energy levels on rsDECT and iodine maps improves tumor conspicuity. This situation may be help better detection of pancreatic tumors.
Identifiants
pubmed: 30155698
doi: 10.1007/s00261-018-1754-2
pii: 10.1007/s00261-018-1754-2
doi:
Substances chimiques
Contrast Media
0
Iodine
9679TC07X4
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM