Spatiotemporal resolved sampling for the interpretation of micropollutant removal during riverbank filtration.

Benzotriazole Carbamazepine Flood events Micropollutants Riverbank filtration Sulfamethoxazole

Journal

The Science of the total environment
ISSN: 1879-1026
Titre abrégé: Sci Total Environ
Pays: Netherlands
ID NLM: 0330500

Informations de publication

Date de publication:
01 Feb 2019
Historique:
received: 13 07 2018
revised: 21 08 2018
accepted: 22 08 2018
pubmed: 3 9 2018
medline: 3 9 2018
entrez: 3 9 2018
Statut: ppublish

Résumé

Riverbank filtration (RBF) systems along rivers are widely used as public water supplies. In these systems, many organic micropollutants (OMPs) are attenuated, but some compounds have shown to be rather persistent. Their fate and transport has been studied in RBF sites along lakes and small rivers, but not extensively along large and dynamic rivers. Therefore, the influence of flood events on OMP behavior in these large and dynamic RBF sites was investigated. Monthly samples were taken from surface- and groundwater up to a distance of 900 m from the riverbank of the Danube from March 2014 till May 2016. Two flood events were sampled more extensively nearby the river. Results showed that changes in flow conditions in the river not only caused changes in OMP concentrations, but also in their load. It was seen that the load of benzotriazole, carbamazepine and sulfamethoxazole in the river increased with increasing river discharges. After a relatively long, oxic groundwater passage, several OMPs were reduced. In contrast to previous work, we found that benzotriazole was almost fully removed under oxic conditions. When entering the aquifer, benzotriazole concentrations were significantly reduced and at a distance of 550 m from the river, >97% was degraded. Carbamazepine and sulfamethoxazole showed relatively persistent behavior in the aquifer. The concentrations measured during flood events were in the same range as seasonal sampling. Furthermore concentrations in the groundwater were higher during these events than in the Danube and can reach further into the aquifer. During flood events some highly degradable compounds (i.e. diclofenac) were found up to a distance of 24 m from the river. These results implied that drinking water utilities with RBF wells in oxic, alluvial aquifers located close to highly dynamic rivers need to consider a potential reduction in groundwater quality during and directly after flood events.

Identifiants

pubmed: 30173030
pii: S0048-9697(18)33271-6
doi: 10.1016/j.scitotenv.2018.08.300
pii:
doi:

Types de publication

Journal Article

Langues

eng

Pagination

212-223

Informations de copyright

Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

Auteurs

Inge H van Driezum (IH)

Institute of Hydraulic Engineering and Water Resources Management, Technische Universität Wien, E222/2, Karlsplatz 13, 1040 Vienna, Austria; Centre for Water Resource Systems, Technische Universität Wien, Karlsplatz 13, 1040 Vienna, Austria. Electronic address: driezum@hydro.tuwien.ac.at.

Julia Derx (J)

Institute of Hydraulic Engineering and Water Resources Management, Technische Universität Wien, E222/2, Karlsplatz 13, 1040 Vienna, Austria; Centre for Water Resource Systems, Technische Universität Wien, Karlsplatz 13, 1040 Vienna, Austria.

Thomas J Oudega (TJ)

Institute of Hydraulic Engineering and Water Resources Management, Technische Universität Wien, E222/2, Karlsplatz 13, 1040 Vienna, Austria; Centre for Water Resource Systems, Technische Universität Wien, Karlsplatz 13, 1040 Vienna, Austria.

Matthias Zessner (M)

Centre for Water Resource Systems, Technische Universität Wien, Karlsplatz 13, 1040 Vienna, Austria; Institute for Water Quality and Resource Management, Technische Universität Wien, E226/1, Karlsplatz 13, 1040 Vienna, Austria.

Floris L Naus (FL)

Copernicus Institute of Sustainable Development, Utrecht University, Utrecht, the Netherlands.

Ernis Saracevic (E)

Institute for Water Quality and Resource Management, Technische Universität Wien, E226/1, Karlsplatz 13, 1040 Vienna, Austria.

Alexander K T Kirschner (AKT)

Institute for Hygiene and Applied Immunology, Water Hygiene, Medical University Vienna, Kinderspitalgasse 15, 1090 Vienna, Austria; Department for Water Quality and Health, Karl Landsteiner University for Health Sciences, Dr. Karl Dorrek Straße 30, 3500 Krems, Austria.

Regina Sommer (R)

Institute for Hygiene and Applied Immunology, Water Hygiene, Medical University Vienna, Kinderspitalgasse 15, 1090 Vienna, Austria. Electronic address: regina.sommer@meduniwien.ac.at.

Andreas H Farnleitner (AH)

Department for Water Quality and Health, Karl Landsteiner University for Health Sciences, Dr. Karl Dorrek Straße 30, 3500 Krems, Austria; Research Group Environmental Microbiology and Molecular Diagnostics, Institute for Chemical, Environmental and Biological Engineering 166/5/r3, Technische Universität Wien, Gumpendorferstrasse 1a, 1060 Vienna, Austria.

Alfred Paul Blaschke (AP)

Institute of Hydraulic Engineering and Water Resources Management, Technische Universität Wien, E222/2, Karlsplatz 13, 1040 Vienna, Austria; Centre for Water Resource Systems, Technische Universität Wien, Karlsplatz 13, 1040 Vienna, Austria.

Classifications MeSH