Transesophageal Echocardiographic Measurements of the Superior Vena Cava for Predicting Fluid Responsiveness in Patients Undergoing Invasive Positive Pressure Ventilation.
intravascular volume status
positive pressure ventilation
superior vena cava
transesophageal echocardiography
vascular ultrasound
Journal
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
ISSN: 1550-9613
Titre abrégé: J Ultrasound Med
Pays: England
ID NLM: 8211547
Informations de publication
Date de publication:
Jun 2019
Jun 2019
Historique:
received:
02
07
2018
accepted:
19
09
2018
pubmed:
10
10
2018
medline:
24
12
2019
entrez:
10
10
2018
Statut:
ppublish
Résumé
Preoperative fasting, water deprivation, and intraoperative fluid loss and redistribution result in hypovolemia in patients undergoing surgery. Some findings have indicated that the superior vena cava (SVC) diameter and variation, as determined by transesophageal echocardiography during surgery, do not reflect central venous pressure effectively. This study aimed to compare and correlate the SVC diameter and variation with the stroke volume variation for predicting fluid responsiveness in patients undergoing invasive positive pressure ventilation. Thirty-six patients scheduled for elective gastrointestinal surgery under general anesthesia with invasive positive pressure ventilation were included in this study. After anesthesia induction, the stroke volume variation, SVC diameter, mean arterial pressure, central venous pressure, and pulse were recorded, and measurements after fluid challenge were recorded as well. The SVC variation was calculated before and after the fluid challenge. After the fluid challenge, the SVC diameter markedly increased, whereas the SVC variation and stroke volume variation significantly decreased (P < .05). The optimal cutoff value for the SVC variation was 21.1%, and the area under the curve (AUC) from a receiver operating characteristic curve analysis was 0.849. The optimal cutoff value for the minimal SVC diameter was 1.135 cm, and that AUC was 0.929. In addition, the optimal cutoff value for the maximal SVC diameter was 1.480 cm, and the AUC was 0.862. The minimal SVC diameter may be an effective indicator for predicting fluid responsiveness in patients undergoing invasive positive pressure ventilation.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1519-1525Subventions
Organisme : Jiangsu Province Commission of Health and Family Planning Project
ID : H2017038
Organisme : Lianyungang Health and Family Planning Project
ID : 201602
Informations de copyright
© 2018 by the American Institute of Ultrasound in Medicine.