We compared maximal plasma concentrations (Cmax) of sildenafil and metabolite n-desmethyl sildenafil in 12 inpatients with left ventricular assist devices (LVADs) on sildenafil (60 mg/day) to the reference range. Sildenafil Cmax (156.8 ± 124.5 ng/ml) was elevated in 66% of patients, with a two to fivefold increase over the upper limit of the reference range in 25% of patients. Metabolite Cmax (133.3 ± 102.0 ng/ml) was elevated in 75% of patients, with a three to sevenfold increase over the upper limit of the reference range in 40% of patients. Patients with heart failure and LVADs are at increased risk of concentrated-related sildenafil adverse events.
Identifiants
pubmed: 30299299
doi: 10.1097/MAT.0000000000000886
pmc: PMC6447486
mid: NIHMS1506399
doi:
Substances chimiques
Phosphodiesterase 5 Inhibitors
0
Sildenafil Citrate
BW9B0ZE037
Types de publication
Journal Article
Research Support, N.I.H., Extramural
Langues
eng
Sous-ensembles de citation
IM
Pagination
530-532Subventions
Organisme : NCATS NIH HHS
ID : UL1 TR000445
Pays : United States
Organisme : NCATS NIH HHS
ID : UL1 TR002243
Pays : United States
Références
J Clin Pharmacol. 2008 Dec;48(12):1451-9
pubmed: 18832294
Circulation. 2010 Jul 6;122(1):88-95
pubmed: 20606131
J Am Coll Cardiol. 1999 Jan;33(1):273-82
pubmed: 9935041
JAMA. 2013 Mar 27;309(12):1268-77
pubmed: 23478662
Pharmacogenomics J. 2018 Apr;18(2):232-237
pubmed: 28440343