Diagnostic Value of Energy Dispersive Hand-Held X-ray Fluorescence Spectrometry in Determining Trace Element Concentrations in Ovine Liver.
Copper
Liver
Sheep
Spectrometry
Trace element
X-ray fluorescence
Zinc
Journal
Biological trace element research
ISSN: 1559-0720
Titre abrégé: Biol Trace Elem Res
Pays: United States
ID NLM: 7911509
Informations de publication
Date de publication:
Aug 2019
Aug 2019
Historique:
received:
15
08
2018
accepted:
08
10
2018
pubmed:
14
10
2018
medline:
6
2
2020
entrez:
14
10
2018
Statut:
ppublish
Résumé
There are no data available on the use of hand-held X-ray fluorescence (XRF) spectrometry to determine trace element concentrations in veterinary diagnostics. The hand-held XRF spectrometer is easy to use and does not require extensive training for the operator. In Sub-Saharan Africa with few centralised analytical laboratories equipped with expensive apparatus or mass spectrometry capabilities, trace element analysis using the hand-held XRF spectrometer provides an alternative. The objective of this study was to compare ovine hepatic copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), selenium (Se) and zinc (Zn) concentrations as obtained with the hand-held XRF spectrometer to those of a reference laboratory using inductively coupled plasma mass spectrometry (ICP-MS). Thirty ovine livers were obtained from an abattoir; prepared as wet blended and oven-dried samples and analysed. Bayesian correlation was used to assess the correspondence between results from the XRF and ICP-MS analyses. The oven-dried preparation procedure for XRF provided the best correlation with the ICP-MS data. The correlations for Cu and Zn were strong and the XRF method may represent a suitable substitute for ICP-MS analysis. For Mn and Fe the correlations were moderately strong and the XRF method may be suitable. For Mo, the correlation was weak and XRF cannot be recommended. Selenium could not be detected in samples prepared by either method. Hand-held XRF spectrometry was a practical method to determine liver concentrations of specific trace elements under African conditions and may significantly reduce the turn-around time of analysis, but unfortunately the apparatus is expensive.
Identifiants
pubmed: 30315508
doi: 10.1007/s12011-018-1546-0
pii: 10.1007/s12011-018-1546-0
doi:
Substances chimiques
Trace Elements
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
358-361Subventions
Organisme : National Research Foundation
ID : 103747