Characterization of Corneoscleral Geometry Using Fourier Transform Profilometry in the Healthy Eye.


Journal

Eye & contact lens
ISSN: 1542-233X
Titre abrégé: Eye Contact Lens
Pays: United States
ID NLM: 101160941

Informations de publication

Date de publication:
May 2019
Historique:
pubmed: 17 10 2018
medline: 15 6 2019
entrez: 17 10 2018
Statut: ppublish

Résumé

To characterize peculiarities of the corneoscleral geometry in healthy eyes. This is a prospective case series including 88 healthy eyes of 88 patients with an age ranging from 21 to 73 years. A complete ocular examination was performed with emphasis on the analysis of the corneoscleral topographic profile with the Fourier transform profilometer Eye Surface Profiler (Eaglet-Eye BV, Houten, the Netherlands). The distribution of different topographic parameters was evaluated, as well as the correlations between corneal and scleroconjunctival parameters. Mean values of 8.64±0.37 (range, 7.81-9.50 mm), 6.06±0.52 (4.88-7.63 mm) and 11.93±1.32 mm (8.17-15.89 mm) were obtained for inner, limbal, and outer best-fit sphere, respectively. Mean values of 8.54±0.38 (7.86-9.66 mm) and 13.35±1.29 mm (11.05-17.31 mm) were obtained for mean corneal and scleral radius, respectively. Regarding tangent angles at limbus, mean values of 35.31±6.55°, 38.76±5.90°, 32.75±7.04°, and 25.91±8.99° were obtained for nasal, temporal, superior, and inferior angles, respectively. Mean difference between temporal and nasal sagittal heights increased from -1.48±120.70 μm for a chord of 11 mm to 73.53±236.55 μm for a chord of 14 mm. A weak but statistically significant correlation was found between corneal and scleral radii (r=0.325, P=0.004). The maximum sagittal height for a diameter of 12 mm was significantly correlated with flattest keratometry, astigmatism, corneal diameter, and corneal eccentricity (R: 0.77, P<0.001). The scleroconjunctival surface in the healthy eye presents some level of nasotemporal asymmetry that is higher with increasing diameters of analysis.

Identifiants

pubmed: 30325762
doi: 10.1097/ICL.0000000000000560
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

201-207

Auteurs

David P Piñero (DP)

Group of Optics and Visual Perception (D.P.P., A.M.-A.), Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain; Department of Ophthalmology (OFTALMAR) (D.P.P., R.S.-N.), Vithas Medimar International Hospital, Alicante, Spain; Aragón Institute for Engineering Research (i3A) (M.A.A.-G.), University of Zaragoza, Zaragoza, Spain; and Department of Optics II (G.C.), University Complutense of Madrid, Madrid, Spain.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH