Many visually impaired and blind patients regain reading ability by using magnification aids. They are tested and prescribed in a time-intensive consultation at our low-vision clinic. Thus, the question arises if it is possible to automate the selection and prescription of low-vision aids only on the basis of the patients' records. The following parameters were extracted from the database of medical records from the low-vision clinic between 2001 and 2006: diagnosis, visual acuity, magnification need, prescribed low-vision aid and prescription request. The prescriptions (optic magnifiers, electronic magnifiers and closed-circuit television) were predicted by statistical models and compared with the real prescription. The database research provided the records of 1203 patients. Sixty-four percent were female and the median age was 80 years. The prescriptions consisted of 29% closed-circuit televisions, 11% electronic magnifiers, 34% optic magnifiers and 26% other aids or no aids. Overall, the statistically predicted prescription matched the real prescription of the magnification aids in only 73% of the cases. The magnification need was the most significant statistical factor. The reliability of an automated prescription of low-vision magnification aids on the basis of the patient record was not sufficient to implement this in the standard clinical process. Thus, an individual and personal consultation with detailed testing of magnification aids is important. In addition to the prescription of low-vision magnification aids, a psycho-social consultation is also provided in a low-vision clinic. Viele Sehbehinderte und Blinde können mit vergrößernden Sehhilfen wieder Lesefähigkeit erreichen. Diese Hilfsmittel werden an der Klinik für Augenheilkunde in Freiburg in der Sehbehindertenambulanz im Rahmen einer zeitaufwendigen Sprechstunde erprobt und verordnet. Es stellt sich deshalb die Frage, ob die Auswahl und Verordnung der Sehhilfen auch automatisiert nach Aktenlage möglich ist. Mittels Datenbankrecherche wurden zwischen 2001 und 2016 folgende Parameter aus den Arztbriefen der Sehbehindertenambulanz extrahiert: Diagnose, bestkorrigierte Sehschärfe, Vergrößerungsbedarf, verordnete Sehhilfe und Versorgungswunsch. Die Sehhilfenverordnungen (optische Lupen, elektronische Lupen und Bildschirmlesegeräte) wurden mittels statistischer Modelle vorhergesagt und mit den tatsächlichen Verordnungen verglichen. Die Datenbankrecherche erbrachte insgesamt 1203 Patienten. 64% waren weiblich, das mediane Lebensalter betrug 80 Jahre. Verordnet wurden 29% Bildschirmlesegeräte, 11% elektronische Lupen, 34% optische Lupen und 26% sonstige Hilfsmittel bzw. kein Hilfsmittel. Die Übereinstimmung zwischen statistisch vorhergesagter und tatsächlicher Sehhilfenverordnung betrug insgesamt nur 73%. Dabei erwies sich der Vergrößerungsbedarf als statistisch signifikantester Faktor. Die Zuverlässigkeit einer automatisierten Verordnung von vergrößernden Sehhilfen nach Aktenlage ist für den klinischen Alltag nicht ausreichend. Deshalb ist eine individuelle und persönliche Beratung mit ausführlicher Erprobung von vergrößernden Sehhilfen in der Sprechstunde wichtig. Hinzu kommt, dass dort neben der reinen Hilfsmittelverordnung regelhaft auch eine psychosoziale Beratung erfolgt.

Sections du résumé

BACKGROUND BACKGROUND
Many visually impaired and blind patients regain reading ability by using magnification aids. They are tested and prescribed in a time-intensive consultation at our low-vision clinic. Thus, the question arises if it is possible to automate the selection and prescription of low-vision aids only on the basis of the patients' records.
METHODS METHODS
The following parameters were extracted from the database of medical records from the low-vision clinic between 2001 and 2006: diagnosis, visual acuity, magnification need, prescribed low-vision aid and prescription request. The prescriptions (optic magnifiers, electronic magnifiers and closed-circuit television) were predicted by statistical models and compared with the real prescription.
RESULTS RESULTS
The database research provided the records of 1203 patients. Sixty-four percent were female and the median age was 80 years. The prescriptions consisted of 29% closed-circuit televisions, 11% electronic magnifiers, 34% optic magnifiers and 26% other aids or no aids. Overall, the statistically predicted prescription matched the real prescription of the magnification aids in only 73% of the cases. The magnification need was the most significant statistical factor.
CONCLUSION CONCLUSIONS
The reliability of an automated prescription of low-vision magnification aids on the basis of the patient record was not sufficient to implement this in the standard clinical process. Thus, an individual and personal consultation with detailed testing of magnification aids is important. In addition to the prescription of low-vision magnification aids, a psycho-social consultation is also provided in a low-vision clinic.
HINTERGRUND UNASSIGNED
Viele Sehbehinderte und Blinde können mit vergrößernden Sehhilfen wieder Lesefähigkeit erreichen. Diese Hilfsmittel werden an der Klinik für Augenheilkunde in Freiburg in der Sehbehindertenambulanz im Rahmen einer zeitaufwendigen Sprechstunde erprobt und verordnet. Es stellt sich deshalb die Frage, ob die Auswahl und Verordnung der Sehhilfen auch automatisiert nach Aktenlage möglich ist.
METHODEN METHODS
Mittels Datenbankrecherche wurden zwischen 2001 und 2016 folgende Parameter aus den Arztbriefen der Sehbehindertenambulanz extrahiert: Diagnose, bestkorrigierte Sehschärfe, Vergrößerungsbedarf, verordnete Sehhilfe und Versorgungswunsch. Die Sehhilfenverordnungen (optische Lupen, elektronische Lupen und Bildschirmlesegeräte) wurden mittels statistischer Modelle vorhergesagt und mit den tatsächlichen Verordnungen verglichen.
ERGEBNISSE UNASSIGNED
Die Datenbankrecherche erbrachte insgesamt 1203 Patienten. 64% waren weiblich, das mediane Lebensalter betrug 80 Jahre. Verordnet wurden 29% Bildschirmlesegeräte, 11% elektronische Lupen, 34% optische Lupen und 26% sonstige Hilfsmittel bzw. kein Hilfsmittel. Die Übereinstimmung zwischen statistisch vorhergesagter und tatsächlicher Sehhilfenverordnung betrug insgesamt nur 73%. Dabei erwies sich der Vergrößerungsbedarf als statistisch signifikantester Faktor.
SCHLUSSFOLGERUNGEN UNASSIGNED
Die Zuverlässigkeit einer automatisierten Verordnung von vergrößernden Sehhilfen nach Aktenlage ist für den klinischen Alltag nicht ausreichend. Deshalb ist eine individuelle und persönliche Beratung mit ausführlicher Erprobung von vergrößernden Sehhilfen in der Sprechstunde wichtig. Hinzu kommt, dass dort neben der reinen Hilfsmittelverordnung regelhaft auch eine psychosoziale Beratung erfolgt.

Autres résumés

Type: Publisher (ger)
Viele Sehbehinderte und Blinde können mit vergrößernden Sehhilfen wieder Lesefähigkeit erreichen. Diese Hilfsmittel werden an der Klinik für Augenheilkunde in Freiburg in der Sehbehindertenambulanz im Rahmen einer zeitaufwendigen Sprechstunde erprobt und verordnet. Es stellt sich deshalb die Frage, ob die Auswahl und Verordnung der Sehhilfen auch automatisiert nach Aktenlage möglich ist.

Identifiants

pubmed: 30357765
doi: 10.1055/a-0672-1207
doi:

Types de publication

Journal Article

Langues

ger

Sous-ensembles de citation

IM

Pagination

907-910

Informations de copyright

Georg Thieme Verlag KG Stuttgart · New York.

Déclaration de conflit d'intérêts

Die Autoren geben an, dass kein Interessenkonflikt besteht.

Auteurs

Diana Engesser (D)

Klinik für Augenheilkunde, Uniklinikum Freiburg, Freiburg.

Raphael Engesser (R)

Institut für Physik, Albert-Ludwigs-Universität Freiburg, Freiburg.

Julia Stifter (J)

Klinik für Augenheilkunde, Uniklinikum Freiburg, Freiburg.

Lisa Atzrodt (L)

Klinik für Augenheilkunde, Uniklinikum Freiburg, Freiburg.

Daniel Böhringer (D)

Klinik für Augenheilkunde, Uniklinikum Freiburg, Freiburg.

Thomas Reinhard (T)

Klinik für Augenheilkunde, Uniklinikum Freiburg, Freiburg.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH