Differential diagnosis of gallbladder polypoid lesions using contrast-enhanced ultrasound.
Adult
Aged
Aged, 80 and over
Contrast Media
Diagnosis, Differential
Female
Gallbladder
/ diagnostic imaging
Gallbladder Diseases
/ complications
Humans
Image Enhancement
/ methods
Male
Middle Aged
Polyps
/ complications
Reproducibility of Results
Retrospective Studies
Sensitivity and Specificity
Ultrasonography
/ methods
Contrast-enhanced ultrasound
Gallbladder cancer
Gallbladder polyp
Sonazoid
Journal
Abdominal radiology (New York)
ISSN: 2366-0058
Titre abrégé: Abdom Radiol (NY)
Pays: United States
ID NLM: 101674571
Informations de publication
Date de publication:
04 2019
04 2019
Historique:
pubmed:
28
11
2018
medline:
17
6
2020
entrez:
28
11
2018
Statut:
ppublish
Résumé
The purpose of the study is to evaluate the utility of contrast-enhanced ultrasound (CEUS) for the differential diagnosis of gallbladder polypoid lesions (GPLs). Thirty-six patients with GPLs (17 with gallbladder cancer, 19 with benign polyps) who underwent CEUS were enrolled in the study. The mean age of patients was 65.7 ± 12.6 years. Perflubutane-based contrast agent and high-mechanical index mode, which can eliminate the background B-mode and provide precise visualization of tumor vessels, were used for CEUS, and two blinded readers evaluated the images, retrospectively. Patient age and size of malignant GPLs (72.4 ± 9.4 years and 23.4 ± 7.5 mm) were significantly greater than those for benign lesions (59.6 ± 12.3 years and 12.4 ± 2.9 mm) (P < 0.01, respectively), and the receiver operating characteristic analysis showed the cut-off value as over 65 years and 16 mm. Univariate analysis showed that heterogeneity in B-mode (80% [12/15]), sessile shape (76% [13/17]), dilated vessel (71% [12/17]), irregular vessel (82% [14/17]), and heterogeneous enhancement (59% [10/17]) on CEUS were significantly correlated with malignant GPLs (P < 0.01, respectively). On CEUS, the diagnostic criterion for malignant GPLs was defined as having one or more of the above four features because of the highest accuracy. Sensitivity, specificity, and accuracy for malignant GBLs were 88%, 68%, and 78% for patient age; 76%, 89%, and 83% for size of GPLs; 80%, 68%, and 74% for B-mode; and 94%, 89%, and 92% for CEUS, respectively. CEUS is useful for the differential diagnosis of malignant and benign GPLs.
Identifiants
pubmed: 30478647
doi: 10.1007/s00261-018-1833-4
pii: 10.1007/s00261-018-1833-4
doi:
Substances chimiques
Contrast Media
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM