Computed Tomography-Estimated Right Ventricular Function and Exercise Capacity in Patients with Continuous-Flow Left Ventricular Assist Devices.
Journal
ASAIO journal (American Society for Artificial Internal Organs : 1992)
ISSN: 1538-943X
Titre abrégé: ASAIO J
Pays: United States
ID NLM: 9204109
Informations de publication
Date de publication:
01 2020
01 2020
Historique:
pubmed:
30
11
2018
medline:
9
9
2020
entrez:
30
11
2018
Statut:
ppublish
Résumé
Using four-dimensional (4D) cardiac computed tomography (CCT) scans at rest and immediately after exercise, we examined the right heart chamber sizes and systolic function and its association with exercise capacity in left ventricular assist device (LVAD) recipients. Fifteen patients with HeartMate (HM) II or 3 underwent echocardiography and maximal cardiopulmonary exercise test. Subsequently, contrast-enhanced CCT scans were performed at rest and immediately after two minutes of supine 25 Watt ergometer bike exercise. Patients were (60 ± 12 years of age) 377 ± 347 days postimplant. Peak oxygen uptake (pVO2) was 15 ± 5 ml/kg/min. LV ejection fraction measured by echocardiography was 15 ± 9%. Pump speed was 9500 ± 258 in HM II and 5518 ± 388 rpm in HM 3 recipients. Resting right atrial ejection fraction (RAEF) was 18 ± 9%, and right ventricular ejection fraction (RVEF) was 36 ± 8%. During stress, RAEF was 19 ± 10%, and RVEF was 37 ± 8%. RAEF and RVEF did not correlate significantly with pVO2 at rest or during stress. Resting-RAEF and stress RAEF correlated significantly: r = 0.87, p < 0.01 as did resting RVEF and stress RVEF: r = 0.76, p < 0.01. In conclusion, resting-EF predicted stress-EF for both RA and RV in patients with an LVAD. Neither RVEF nor RAEF correlated with pVO2.
Identifiants
pubmed: 30489293
doi: 10.1097/MAT.0000000000000925
pii: 00002480-202001000-00002
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
8-16Références
Jung MH, Gustafsson F. Exercise in heart failure patients supported with a left ventricular assist device. J Heart Lung Transplant 2015.34: 489–496
Jung MH, Houston B, Russell SD, Gustafsson F. Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients: A double-blind, randomized trial. J Heart Lung Transplant 2017.36: 36–41
Jung MH, Hansen PB, Sander K, et al. Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device. A double-blind randomized study. Eur J Heart Fail 2014.16:403–408
Gustafsson F, Rogers JG. Left ventricular assist device therapy in advanced heart failure: Patient selection and outcomes. Eur J Heart Fail 2017.19: 595–602
Sigvardsen PE, Larsen LH, Carstensen HG, et al. Prognostic implications of left ventricular asymmetry in patients with asymptomatic aortic valve stenosis. Eur Heart J Cardiovasc Imaging 2018.19: 168–175
Garcia-Alvarez A, Fernandez-Friera L, Lau JF, et al. Evaluation of right ventricular function and post-operative findings using cardiac computed tomography in patients with left ventricular assist devices. J Heart Lung Transplant 2011.30: 896–903
Hayek S, Sims DB, Markham DW, Butler J, Kalogeropoulos AP. Assessment of right ventricular function in left ventricular assist device candidates. Circ Cardiovasc Imaging 2014.7: 379–389
Hindsø L, Fuchs A, Kühl JT, et al. Normal values of regional left ventricular myocardial thickness, mass and distribution-assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study. Int J Cardiovasc Imaging 2017.33: 421–429
Rudski LG, Lai WW, Afilalo J, et al. Guidelines for the echocardiographic assessment of the right heart in adults: A report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr 2010.23: 685–713; quiz 786
Du Bois D, Du Bois EF. Clinical calorimetry: Tenth paper a formula to estimate the approximate surface area if height and weight be known. Arch Intern Med. 1916.XVII:863–871
Borg G. Psychophysical scaling with applications in physical work and the perception of exertion. Scand J Work Environ Health 1990.16(suppl 1): 55–58
Hansen JE, Sue DY, Wasserman K. Predicted values for clinical exercise testing. Am Rev Respir Dis 1984.129:S49–S55
Matthews JC, Koelling TM, Pagani FD, Aaronson KD. The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol 2008.51: 2163–2172
Dang NC, Topkara VK, Mercando M, et al. Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure. J Heart Lung Transplant 2006.25: 1–6
Sabashnikov A, Mohite PN, Zych B, et al. Outcomes and predictors of early mortality after continuous-flow left ventricular assist device implantation as a bridge to transplantation. ASAIO J 2014.60: 162–169
Loghmanpour NA, Kormos RL, Kanwar MK, Teuteberg JJ, Murali S, Antaki JF. A Bayesian model to predict right ventricular failure following left ventricular assist device therapy. JACC Heart Fail 2016.4: 711–721
Morgan JA, Paone G, Nemeh HW, et al. Impact of continuous-flow left ventricular assist device support on right ventricular function. J Heart Lung Transplant 2013.32: 398–403
Kavarana MN, Pessin-Minsley MS, Urtecho J, et al. Right ventricular dysfunction and organ failure in left ventricular assist device recipients: A continuing problem. Ann Thorac Surg 2002.73: 745–750
Furukawa K, Motomura T, Nosé Y. Right ventricular failure after left ventricular assist device implantation: The need for an implantable right ventricular assist device. Artif Organs 2005.29: 369–377
Baker BJ, Wilen MM, Boyd CM, Dinh H, Franciosa JA. Relation of right ventricular ejection fraction to exercise capacity in chronic left ventricular failure. Am J Cardiol 1984.54:596–599
Elshazly MB, Senn T, Wu Y, et al. Impact of atrial fibrillation on exercise capacity and mortality in heart failure with preserved ejection fraction: Insights from cardiopulmonary stress testing. J Am Heart Assoc 2017.6: e006662
Rossing K, Jung MH, Sander K, et al. Outcomes and hospital admissions during long-term support with a HeartMate II. Scand Cardiovasc J 2015.49: 367–375
Enriquez AD, Calenda B, Gandhi PU, Nair AP, Anyanwu AC, Pinney SP. Clinical impact of atrial fibrillation in patients with the HeartMate II left ventricular assist device. J Am Coll Cardiol 2014.64: 1883–1890
Di Salvo TG, Mathier M, Semigran MJ, Dec GW. Preserved right ventricular ejection fraction predicts exercise capacity and survival in advanced heart failure. J Am Coll Cardiol 1995.25: 1143–1153
Murninkas D, Alba AC, Delgado D, et al. Right ventricular function and prognosis in stable heart failure patients. J Card Fail 2014.20: 343–349