Laparoscopic repositioning of a dislocated pacemaker into the rectovesical pouch.
dislocation
epicardial pacemaker
laparoscopy
migration
rectovesical pouch
Journal
Pacing and clinical electrophysiology : PACE
ISSN: 1540-8159
Titre abrégé: Pacing Clin Electrophysiol
Pays: United States
ID NLM: 7803944
Informations de publication
Date de publication:
05 2019
05 2019
Historique:
received:
21
08
2018
revised:
27
11
2018
accepted:
03
12
2018
pubmed:
16
12
2018
medline:
4
12
2019
entrez:
16
12
2018
Statut:
ppublish
Résumé
Dislocation of the epicardial pacemaker into the peritoneal cavity is an uncommon but potentially life-threatening complication. We report a case of a 74 year old with an abdominally implanted epicardial pacemaker that migrated through the peritoneum to the excavatio rectovesicalis. The laparoscopic approach was chosen because of the increased risks of perioperative morbidity and decreased survival. The generator was implanted into a pocket beneath the anterior rectus sheath and the lead was peritonalized with a running suture. In conclusion, a laparoscopic retrieval is feasible and safe in the treatment of a displaced pacemaker in the rectovesical pouch.
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
560-562Informations de copyright