A chemometric strategy for forensic analysis of condom residues: Identification and marker profiling of condom brands from direct analysis in real time-high resolution mass spectrometric chemical signatures.
Brand
Chemometrics
Condom brand
Conformal prediction
Direct analysis in real time mass spectrometry
Lubricant
Sexual assault
Journal
Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R
Informations de publication
Date de publication:
01 Mar 2019
01 Mar 2019
Historique:
received:
16
07
2018
revised:
25
09
2018
accepted:
27
09
2018
entrez:
6
1
2019
pubmed:
6
1
2019
medline:
1
3
2019
Statut:
ppublish
Résumé
The rapid and accurate identification of condom-derived lubricant traces takes on heightened importance in sexual assault cases where the assailant has used a condom in order to avoid leaving behind incriminating DNA evidence. Previous reports have demonstrated that a variety of techniques can be used to confirm that a given residue is condom-derived, based on the detection of spermicides, slip agents and/or other common additives. However, limited success has been achieved in differentiating brands from among a broad range of condom types. In this study, the utility of direct analysis in real time-high resolution mass spectrometry (DART-HRMS) combined with chemometrics, for the rapid and accurate attribution of brands to condom residues of various types, was explored and developed. A database of condom residue spectra comprised of 110 different condom types representing 16 brands was generated, with the spectra serving as representative fingerprints for each brand. The spectral fingerprints were subjected to pre-processing prior to the application of Partial Least Squares-Discriminant Analysis (PLS-DA) which was used to generate a classifier that permitted identification of condom brands with an accuracy of 97.4%. An additional criterion was imposed on the PLS-DA to provide the confidence level and credibility of each prediction. The effect of time since deposition, the presence of contaminants and the influence of residue transfer on the prediction accuracy of the model were also assessed. The results from Sparse Discriminant Analysis (SDA) and PLS-DA were followed by application of the Student's t-test to determine m/z values representative of small-molecule markers that were most important for defining brand classes. The m/z values revealed by the two methods were found to be consistent in indicating which masses were representative of markers. The SDA method also provided low-dimensional views of the discriminative directions for classification of condom residues, thereby enabling easy visualization of the relationship between the indicated m/z values and brand discrimination. The results further revealed a subset of 14 m/z values that were observed in all 110 condoms representing the 16 brands, and some of these may serve as potential universal small-molecule condom markers. Overall, the results show that the DART-HRMS database of condom residue spectra can be used to identify residues based on differences in chemical components peculiar to each brand. The database can be readily expanded to include more condoms.
Identifiants
pubmed: 30609574
pii: S0039-9140(18)31019-1
doi: 10.1016/j.talanta.2018.09.101
pii:
doi:
Substances chimiques
Lubricants
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
563-575Informations de copyright
Copyright © 2018 Elsevier B.V. All rights reserved.