A chemometric strategy for forensic analysis of condom residues: Identification and marker profiling of condom brands from direct analysis in real time-high resolution mass spectrometric chemical signatures.


Journal

Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R

Informations de publication

Date de publication:
01 Mar 2019
Historique:
received: 16 07 2018
revised: 25 09 2018
accepted: 27 09 2018
entrez: 6 1 2019
pubmed: 6 1 2019
medline: 1 3 2019
Statut: ppublish

Résumé

The rapid and accurate identification of condom-derived lubricant traces takes on heightened importance in sexual assault cases where the assailant has used a condom in order to avoid leaving behind incriminating DNA evidence. Previous reports have demonstrated that a variety of techniques can be used to confirm that a given residue is condom-derived, based on the detection of spermicides, slip agents and/or other common additives. However, limited success has been achieved in differentiating brands from among a broad range of condom types. In this study, the utility of direct analysis in real time-high resolution mass spectrometry (DART-HRMS) combined with chemometrics, for the rapid and accurate attribution of brands to condom residues of various types, was explored and developed. A database of condom residue spectra comprised of 110 different condom types representing 16 brands was generated, with the spectra serving as representative fingerprints for each brand. The spectral fingerprints were subjected to pre-processing prior to the application of Partial Least Squares-Discriminant Analysis (PLS-DA) which was used to generate a classifier that permitted identification of condom brands with an accuracy of 97.4%. An additional criterion was imposed on the PLS-DA to provide the confidence level and credibility of each prediction. The effect of time since deposition, the presence of contaminants and the influence of residue transfer on the prediction accuracy of the model were also assessed. The results from Sparse Discriminant Analysis (SDA) and PLS-DA were followed by application of the Student's t-test to determine m/z values representative of small-molecule markers that were most important for defining brand classes. The m/z values revealed by the two methods were found to be consistent in indicating which masses were representative of markers. The SDA method also provided low-dimensional views of the discriminative directions for classification of condom residues, thereby enabling easy visualization of the relationship between the indicated m/z values and brand discrimination. The results further revealed a subset of 14 m/z values that were observed in all 110 condoms representing the 16 brands, and some of these may serve as potential universal small-molecule condom markers. Overall, the results show that the DART-HRMS database of condom residue spectra can be used to identify residues based on differences in chemical components peculiar to each brand. The database can be readily expanded to include more condoms.

Identifiants

pubmed: 30609574
pii: S0039-9140(18)31019-1
doi: 10.1016/j.talanta.2018.09.101
pii:
doi:

Substances chimiques

Lubricants 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

563-575

Informations de copyright

Copyright © 2018 Elsevier B.V. All rights reserved.

Auteurs

Allix M Coon (AM)

Department of Chemistry, State University of New York at Albany, 1400 Washington Ave, Albany, NY 12222, United States.

Samira Beyramysoltan (S)

Department of Chemistry, State University of New York at Albany, 1400 Washington Ave, Albany, NY 12222, United States.

Rabi A Musah (RA)

Department of Chemistry, State University of New York at Albany, 1400 Washington Ave, Albany, NY 12222, United States. Electronic address: rmusah@albany.edu.

Articles similaires

Humans Meals Time Factors Female Adult

Vancomycin-associated DRESS demonstrates delay in AST abnormalities.

Ahmed Hussein, Kateri L Schoettinger, Jourdan Hydol-Smith et al.
1.00
Humans Drug Hypersensitivity Syndrome Vancomycin Female Male
Humans Male Female Aged Middle Aged
Humans Peripheral Arterial Disease Retrospective Studies Male Female

Classifications MeSH