Differences in Femoral Torsion Among Various Measurement Methods Increase in Hips With Excessive Femoral Torsion.
Adolescent
Adult
Anatomic Landmarks
Biomechanical Phenomena
Female
Femoracetabular Impingement
/ diagnostic imaging
Femur
/ diagnostic imaging
Hip Joint
/ diagnostic imaging
Humans
Male
Middle Aged
Predictive Value of Tests
Reproducibility of Results
Retrospective Studies
Tomography, X-Ray Computed
Torsion Abnormality
/ diagnostic imaging
Torsion, Mechanical
Young Adult
Journal
Clinical orthopaedics and related research
ISSN: 1528-1132
Titre abrégé: Clin Orthop Relat Res
Pays: United States
ID NLM: 0075674
Informations de publication
Date de publication:
05 2019
05 2019
Historique:
pubmed:
10
1
2019
medline:
18
2
2020
entrez:
10
1
2019
Statut:
ppublish
Résumé
Correct quantification of femoral torsion is crucial to diagnose torsional deformities, make an indication for surgical treatment, or plan the amount of correction. However, no clear evaluation of different femoral torsion measurement methods for hips with excessive torsion has been performed to date. (1) How does CT-based measurement of femoral torsion differ among five commonly used measurement methods? (2) Do differences in femoral torsion among measurement methods increase in hips with excessive femoral torsion? (3) What is the reliability and reproducibility of each of the five torsion measurement methods? Between March and August 2016, we saw 86 new patients (95 hips) with hip pain and physical findings suggestive for femoroacetabular impingement at our outpatient tertiary clinic. Of those, 56 patients (62 hips) had a pelvic CT scan including the distal femur for measurement of femoral torsion. We excluded seven patients (seven hips) with previous hip surgery, two patients (two hips) with sequelae of Legg-Calvé-Perthes disease, and one patient (one hip) with a posttraumatic deformity. This resulted in 46 patients (52 hips) in the final study group with a mean age of 28 ± 9 years (range, 17-51 years) and 27 female patients (59%). Torsion was compared among five commonly used assessment measures, those of Lee et al., Reikerås et al., Jarrett et al., Tomczak et al., and Murphy et al. They differed regarding the level of the anatomic landmark for the proximal femoral neck axis; the method of Lee had the most proximal definition followed by the methods of Reikerås, Jarrett, and Tomczak at the base of the femoral neck and the method of Murphy with the most distal definition at the level of the lesser trochanter. The definition of the femoral head center and of the distal reference was consistent for all five measurement methods. We used the method described by Murphy et al. as our baseline measurement method for femoral torsion because it reportedly most closely reflects true anatomic femoral torsion. With this method we found a mean femoral torsion of 28 ± 13°. Mean values of femoral torsion were compared among the five methods using multivariate analysis of variance. All differences between two of the measurement methods were plotted over the entire range of femoral torsion to evaluate a possible increase in hips with excessive femoral torsion. All measurements were performed by two blinded orthopaedic residents (FS, TDL) at two different occasions to measure intraobserver reproducibility and interobserver reliability using intraclass correlation coefficients (ICCs). We found increasing values for femoral torsion using measurement methods with a more distal definition of the proximal femoral neck axis: Lee et al. (most proximal definition: 11° ± 11°), Reikerås et al. (15° ± 11°), Jarrett et al. (19° ± 11°), Tomczak et al. (25° ± 12°), and Murphy et al. (most distal definition: 28° ± 13°). The most pronounced difference was found for the comparison between the methods of Lee et al. and Murphy et al. with a mean difference of 17° ± 5° (95% confidence interval, 16°-19°; p < 0.001). For six of 10 possible pairwise comparisons, the difference between two methods increased with increasing femoral torsion and decreased with decreasing femoral torsion. We observed a fair-to-strong linear correlation (R range, 0.306-0.622; all p values < 0.05) for any method compared with the Murphy method and for the Reikerås and Jarrett methods when compared with the Tomczak method. For example, a hip with 10° of femoral antetorsion according Murphy had a torsion of 1° according to Reikerås, which corresponds to a difference of 9°. This difference increased to 20° in hips with excessive torsion; for example, a hip with 60° of torsion according to Murphy had 40° of torsion according to Reikerås. All five methods for measuring femoral torsion showed excellent agreement for both intraobserver reproducibility (ICC, 0.905-0.973) and interobserver reliability (ICC, 0.938-0.969). Because the quantification of femoral torsion in hips with excessive femoral torsion differs considerably among measurement methods, it is crucial to state the applied methods when reporting femoral torsion and to be consistent regarding the used measurement method. These differences have to be considered for surgical decision-making and planning the degree of correction. Neglecting the differences among measurement methods to quantify femoral torsion can potentially lead to misdiagnosis and surgical planning errors. Level IV, diagnostic study.
Sections du résumé
BACKGROUND
Correct quantification of femoral torsion is crucial to diagnose torsional deformities, make an indication for surgical treatment, or plan the amount of correction. However, no clear evaluation of different femoral torsion measurement methods for hips with excessive torsion has been performed to date.
QUESTIONS/PURPOSES
(1) How does CT-based measurement of femoral torsion differ among five commonly used measurement methods? (2) Do differences in femoral torsion among measurement methods increase in hips with excessive femoral torsion? (3) What is the reliability and reproducibility of each of the five torsion measurement methods?
METHODS
Between March and August 2016, we saw 86 new patients (95 hips) with hip pain and physical findings suggestive for femoroacetabular impingement at our outpatient tertiary clinic. Of those, 56 patients (62 hips) had a pelvic CT scan including the distal femur for measurement of femoral torsion. We excluded seven patients (seven hips) with previous hip surgery, two patients (two hips) with sequelae of Legg-Calvé-Perthes disease, and one patient (one hip) with a posttraumatic deformity. This resulted in 46 patients (52 hips) in the final study group with a mean age of 28 ± 9 years (range, 17-51 years) and 27 female patients (59%). Torsion was compared among five commonly used assessment measures, those of Lee et al., Reikerås et al., Jarrett et al., Tomczak et al., and Murphy et al. They differed regarding the level of the anatomic landmark for the proximal femoral neck axis; the method of Lee had the most proximal definition followed by the methods of Reikerås, Jarrett, and Tomczak at the base of the femoral neck and the method of Murphy with the most distal definition at the level of the lesser trochanter. The definition of the femoral head center and of the distal reference was consistent for all five measurement methods. We used the method described by Murphy et al. as our baseline measurement method for femoral torsion because it reportedly most closely reflects true anatomic femoral torsion. With this method we found a mean femoral torsion of 28 ± 13°. Mean values of femoral torsion were compared among the five methods using multivariate analysis of variance. All differences between two of the measurement methods were plotted over the entire range of femoral torsion to evaluate a possible increase in hips with excessive femoral torsion. All measurements were performed by two blinded orthopaedic residents (FS, TDL) at two different occasions to measure intraobserver reproducibility and interobserver reliability using intraclass correlation coefficients (ICCs).
RESULTS
We found increasing values for femoral torsion using measurement methods with a more distal definition of the proximal femoral neck axis: Lee et al. (most proximal definition: 11° ± 11°), Reikerås et al. (15° ± 11°), Jarrett et al. (19° ± 11°), Tomczak et al. (25° ± 12°), and Murphy et al. (most distal definition: 28° ± 13°). The most pronounced difference was found for the comparison between the methods of Lee et al. and Murphy et al. with a mean difference of 17° ± 5° (95% confidence interval, 16°-19°; p < 0.001). For six of 10 possible pairwise comparisons, the difference between two methods increased with increasing femoral torsion and decreased with decreasing femoral torsion. We observed a fair-to-strong linear correlation (R range, 0.306-0.622; all p values < 0.05) for any method compared with the Murphy method and for the Reikerås and Jarrett methods when compared with the Tomczak method. For example, a hip with 10° of femoral antetorsion according Murphy had a torsion of 1° according to Reikerås, which corresponds to a difference of 9°. This difference increased to 20° in hips with excessive torsion; for example, a hip with 60° of torsion according to Murphy had 40° of torsion according to Reikerås. All five methods for measuring femoral torsion showed excellent agreement for both intraobserver reproducibility (ICC, 0.905-0.973) and interobserver reliability (ICC, 0.938-0.969).
CONCLUSIONS
Because the quantification of femoral torsion in hips with excessive femoral torsion differs considerably among measurement methods, it is crucial to state the applied methods when reporting femoral torsion and to be consistent regarding the used measurement method. These differences have to be considered for surgical decision-making and planning the degree of correction. Neglecting the differences among measurement methods to quantify femoral torsion can potentially lead to misdiagnosis and surgical planning errors.
LEVEL OF EVIDENCE
Level IV, diagnostic study.
Identifiants
pubmed: 30624313
doi: 10.1097/CORR.0000000000000610
pmc: PMC6494336
doi:
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1073-1083Commentaires et corrections
Type : CommentIn
Références
Clin Orthop Relat Res. 2015 Apr;473(4):1396-403
pubmed: 25384428
J Hip Preserv Surg. 2015 Feb 18;2(1):65-79
pubmed: 27011816
J Pediatr Orthop. 2017 Dec;37(8):557-562
pubmed: 28323254
J Bone Joint Surg Am. 2018 Feb 7;100(3):205-210
pubmed: 29406341
Am J Sports Med. 2018 Jan;46(1):122-134
pubmed: 28937786
AJR Am J Roentgenol. 1997 Mar;168(3):791-4
pubmed: 9057536
Oper Orthop Traumatol. 2018 Apr;30(2):98-110
pubmed: 29589046
Rofo. 1992 Sep;157(3):245-51
pubmed: 1391819
Arthrosc Tech. 2017 Aug 28;6(4):e1405-e1410
pubmed: 29354448
Acta Orthop Scand. 1983 Feb;54(1):18-23
pubmed: 6829278
AJR Am J Roentgenol. 2010 May;194(5):1230-3
pubmed: 20410408
Arch Orthop Trauma Surg. 2016 Sep;136(9):1259-1264
pubmed: 27501703
J Orthop Trauma. 2013 Jun;27(6):308-11
pubmed: 23032191
J Bone Joint Surg Am. 1999 Dec;81(12):1747-70
pubmed: 10608388
J Orthop Res. 2007 Jan;25(1):122-31
pubmed: 17054112
J Bone Joint Surg Am. 2016 Jan 20;98(2):127-34
pubmed: 26791033
Arthroscopy. 2012 May;28(5):619-27
pubmed: 22301362
J Bone Joint Surg Am. 2015 Apr 1;97(7):537-43
pubmed: 25834077
BMC Health Serv Res. 2002 Mar 26;2(1):8
pubmed: 11914164
Int J Numer Method Biomed Eng. 2014 Nov;30(11):1314-25
pubmed: 25044860
Radiology. 2012 May;263(2):475-83
pubmed: 22403167
Comput Aided Surg. 2010;15(4-6):75-82
pubmed: 21067316
J Orthop Res. 1987;5(1):86-91
pubmed: 3819914
Gait Posture. 2018 May;62:285-290
pubmed: 29605796
Comput Biol Med. 2011 May;41(5):285-91
pubmed: 21463859
Semin Musculoskelet Radiol. 2017 Nov;21(5):487-506
pubmed: 29025180
Clin Orthop Relat Res. 2013 Dec;471(12):3774-80
pubmed: 23463288
J Bone Joint Surg Am. 1987 Oct;69(8):1169-76
pubmed: 3667647
Med Biol Eng Comput. 2006 Oct;44(10):895-906
pubmed: 17009027
AJR Am J Roentgenol. 1981 Jul;137(1):97-101
pubmed: 6787898
J Am Acad Orthop Surg. 2018 Oct 1;26(19):e416-e425
pubmed: 30106763