Modified enzyme multiplied immunoassay technique of methotrexate assay to improve sensitivity and reduce cost.
Cost reduction
Enzyme multiplied immunoassay technique
Methotrexate
Sensitivity
Journal
BMC pharmacology & toxicology
ISSN: 2050-6511
Titre abrégé: BMC Pharmacol Toxicol
Pays: England
ID NLM: 101590449
Informations de publication
Date de publication:
09 Jan 2019
09 Jan 2019
Historique:
received:
18
03
2018
accepted:
27
12
2018
entrez:
11
1
2019
pubmed:
11
1
2019
medline:
10
9
2019
Statut:
epublish
Résumé
Methotrexate is an important component in many chemotherapy protocols. The blood concentration of Methotrexate is used to determine the regimen of folinic acid. However, the lower limit of Siemens assay kit is 0.30 μmol/L in China. This study extended the limit from 0.3 to 0.05 μmol/L and reduced the test cost by optimizing the parameters of Enzyme Multiplied Immunoassay Technique assay. Parameters of Enzyme Multiplied Immunoassay Technique assay were modified to decrease the volume of reagents A and B. Then a standard curve with a new custom set of calibrators was prepared to detect low concentration. Intra-day and inter-day imprecision were assessed by control material and samples. The linearity of the modified assay was verified by analyzing a range of quality controls with known concentration from 0.05 to 1.00 μmol/L. At last, the same samples were tested by modified Enzyme Multiplied Immunoassay Technique assay and Liquid Chromatography-tandem Mass Spectrometry assay respectively. A simple linear regression was performed to verify the validity of the modified Enzyme Multiplied Immunoassay Technique assay. Intra-day and inter-day imprecision show good reproducibility at all levels (0.05, 0.12, 0.43, 0.82 μmol/L). The linearity equation of modified assay was y = 0.9913x + 0.0046, in which y was the mean of measured concentration and x was the target concentration (R The modified assay enhanced the sensitivity of Siemens VIVA-E to 0.05 μmol/L. In addition, the test number of a reagent Kit increased from 140 to 210. This means the cost of detection was reduced about 30%.
Sections du résumé
BACKGROUND
BACKGROUND
Methotrexate is an important component in many chemotherapy protocols. The blood concentration of Methotrexate is used to determine the regimen of folinic acid. However, the lower limit of Siemens assay kit is 0.30 μmol/L in China. This study extended the limit from 0.3 to 0.05 μmol/L and reduced the test cost by optimizing the parameters of Enzyme Multiplied Immunoassay Technique assay.
METHODS
METHODS
Parameters of Enzyme Multiplied Immunoassay Technique assay were modified to decrease the volume of reagents A and B. Then a standard curve with a new custom set of calibrators was prepared to detect low concentration. Intra-day and inter-day imprecision were assessed by control material and samples. The linearity of the modified assay was verified by analyzing a range of quality controls with known concentration from 0.05 to 1.00 μmol/L. At last, the same samples were tested by modified Enzyme Multiplied Immunoassay Technique assay and Liquid Chromatography-tandem Mass Spectrometry assay respectively. A simple linear regression was performed to verify the validity of the modified Enzyme Multiplied Immunoassay Technique assay.
RESULTS
RESULTS
Intra-day and inter-day imprecision show good reproducibility at all levels (0.05, 0.12, 0.43, 0.82 μmol/L). The linearity equation of modified assay was y = 0.9913x + 0.0046, in which y was the mean of measured concentration and x was the target concentration (R
CONCLUSIONS
CONCLUSIONS
The modified assay enhanced the sensitivity of Siemens VIVA-E to 0.05 μmol/L. In addition, the test number of a reagent Kit increased from 140 to 210. This means the cost of detection was reduced about 30%.
Identifiants
pubmed: 30626430
doi: 10.1186/s40360-018-0283-5
pii: 10.1186/s40360-018-0283-5
pmc: PMC6327437
doi:
Substances chimiques
Antimetabolites, Antineoplastic
0
Methotrexate
YL5FZ2Y5U1
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
3Références
Ther Drug Monit. 2014 Aug;36(4):499-504
pubmed: 25014075
J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Mar 25;817(2):139-44
pubmed: 15686977
J Pharm Biomed Anal. 2007 Apr 11;43(5):1789-95
pubmed: 17289326
Ther Drug Monit. 2007 Oct;29(5):632-7
pubmed: 17898655
Ther Drug Monit. 2002 Feb;24(1):1-8
pubmed: 11805714
Ther Drug Monit. 2012 Apr;34(2):193-7
pubmed: 22377747
J Chromatogr B Analyt Technol Biomed Life Sci. 2016 Dec 1;1038:88-94
pubmed: 27802917
Am J Clin Pathol. 2016 Jul;146(1):119-24
pubmed: 27357291