Application of a peripheral vein illumination device to reduce saphenous structure injury caused by screw insertion during arthroscopic ankle arthrodesis.


Journal

Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association
ISSN: 1436-2023
Titre abrégé: J Orthop Sci
Pays: Japan
ID NLM: 9604934

Informations de publication

Date de publication:
Jul 2019
Historique:
received: 09 08 2018
revised: 15 11 2018
accepted: 10 12 2018
pubmed: 12 1 2019
medline: 25 1 2020
entrez: 12 1 2019
Statut: ppublish

Résumé

Arthroscopic ankle arthrodesis (AAA) is minimally invasive surgery, whereby percutaneous screw fixation is used through the medial aspect of the distal tibia to fusion the ankle, but it carries the risk of the saphenous vein and nerve injuries. The near-infrared (NIR) vascular imaging system, the VeinViewer Ten patients with the ankle osteoarthritis underwent AAA. Three screw insertion sites (proximal as number 1, anterior distal as number 2, and posterior distal as number 3) were marked and then the vein was depicted on the medial malleolus using the VeinViewer The distance of number 1, 2, and 3 from the vein was 2.4 ± 1.4 mm (range from 0 to 5 mm), 6.3 ± 6.6 mm (range from 0 to 20 mm) and 3.5 ± 3.1 mm (range from 0 to 11 mm) respectively. In anterior screw insertion site, 3 of 10 cases showed just on the vein. The veins were observed at the anterior region from the center axis of the tibia more than 75% of ankles which was suspected as the greater saphenous vein with closely running of the saphenous nerve, but also other regions had the crossing vein. Percutaneous screw fixation during AAA runs the risk of causing the saphenous structure injury. The NIR light imaging system is beneficial in reducing the complications of saphenous structure damage in AAA.

Sections du résumé

BACKGROUND BACKGROUND
Arthroscopic ankle arthrodesis (AAA) is minimally invasive surgery, whereby percutaneous screw fixation is used through the medial aspect of the distal tibia to fusion the ankle, but it carries the risk of the saphenous vein and nerve injuries. The near-infrared (NIR) vascular imaging system, the VeinViewer
METHODS METHODS
Ten patients with the ankle osteoarthritis underwent AAA. Three screw insertion sites (proximal as number 1, anterior distal as number 2, and posterior distal as number 3) were marked and then the vein was depicted on the medial malleolus using the VeinViewer
RESULTS RESULTS
The distance of number 1, 2, and 3 from the vein was 2.4 ± 1.4 mm (range from 0 to 5 mm), 6.3 ± 6.6 mm (range from 0 to 20 mm) and 3.5 ± 3.1 mm (range from 0 to 11 mm) respectively. In anterior screw insertion site, 3 of 10 cases showed just on the vein. The veins were observed at the anterior region from the center axis of the tibia more than 75% of ankles which was suspected as the greater saphenous vein with closely running of the saphenous nerve, but also other regions had the crossing vein.
CONCLUSIONS CONCLUSIONS
Percutaneous screw fixation during AAA runs the risk of causing the saphenous structure injury. The NIR light imaging system is beneficial in reducing the complications of saphenous structure damage in AAA.

Identifiants

pubmed: 30630767
pii: S0949-2658(18)30378-6
doi: 10.1016/j.jos.2018.12.007
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

697-701

Informations de copyright

Copyright © 2019 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

Auteurs

Tomoyuki Nakasa (T)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan. Electronic address: tnakasa0@gmail.com.

Yasunari Ikuta (Y)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan.

Yusuke Tsuyuguchi (Y)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan.

Yuki Ota (Y)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan.

Munekazu Kanemitsu (M)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan.

Nobuo Adachi (N)

Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi Minamiku, Hiroshima city, 734-8551, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH