Bilaterally Asymmetric Corneal Ectasia Following SMILE With Asymmetrically Reduced Stromal Molecular Markers.
Adult
Biomarkers
/ metabolism
Cells, Cultured
Corneal Keratocytes
/ metabolism
Corneal Stroma
/ metabolism
Corneal Surgery, Laser
/ adverse effects
Corneal Topography
Cytokines
/ genetics
Dilatation, Pathologic
/ etiology
Extracellular Matrix Proteins
/ genetics
Eye Proteins
/ metabolism
Female
Gene Expression Profiling
Humans
Keratoconus
/ etiology
Myopia
/ surgery
Real-Time Polymerase Chain Reaction
Refraction, Ocular
/ physiology
Retrospective Studies
Visual Acuity
/ physiology
Journal
Journal of refractive surgery (Thorofare, N.J. : 1995)
ISSN: 1938-2391
Titre abrégé: J Refract Surg
Pays: United States
ID NLM: 9505927
Informations de publication
Date de publication:
01 Jan 2019
01 Jan 2019
Historique:
received:
30
06
2018
accepted:
26
11
2018
entrez:
12
1
2019
pubmed:
12
1
2019
medline:
20
4
2019
Statut:
ppublish
Résumé
To evaluate extracellular matrix regulators and inflammatory factors in a patient who developed ectasia after small incision lenticule extraction (SMILE) despite normal preoperative tomographic and biomechanical evaluation. The SMILE lenticules from both eyes of the patient with ectasia and three control patients (5 eyes) matched for age, sex, and duration of follow-up were used for gene expression analysis of lysyl oxidase (LOX), matrix metalloproteinase 9 (MMP9), collagen types I alpha 1 (COLIA1) and IV alpha 1 chain (COLIVA1), transforming growth factor-beta (TGF-beta), bone morphogenetic protein 7 (BMP7), interleukin-6 (IL-6), cathepsin K, cluster of differentiation 68, integrin beta-1, and tissue inhibitor of metalloproteinase-1 (TIMP1). Furthermore, the functional role of LOX was assessed in vitro by studying the collagen gel contraction efficiency of LOX overexpressing in primary human corneal fibroblast cells. Preoperatively, manifest refraction was -9.25 diopters (D) in the right eye and -10.00 D in the left eye. Corneal thickness, Pentacam (OCULUS Optikgeräte GmbH, Wetzlar, Germany) tomography, and Corvis biomechanical indices (OCULUS Optikgeräte GmbH) were normal. The ectatic eye lenticule (left) had reduced expression of LOX and COLIA1 compared to controls without ectasia. Increased mRNA fold change expression of TGF-beta, BMP7, IL-6, cathepsin K, and integrin beta-1 was noted in the ectatic left eye compared to controls; however, MMP9 and TIMP1 levels were not altered. Ectopic LOX expression in human corneal fibroblast induced significantly more collagen gel contraction, confirming the role of LOX in strengthening the corneal stroma. Reduced preexisting LOX and collagen levels may predispose clinically healthy eyes undergoing refractive surgery to ectasia, presumably by corneal stromal weakening via inadequately cross-linked collagen. Preoperative molecular testing may reveal ectasia susceptibility in the absence of tomographic or biomechanical risk factors. [J Refract Surg. 2019;35(1):6-14.].
Identifiants
pubmed: 30633782
doi: 10.3928/1081597X-20181128-01
doi:
Substances chimiques
Biomarkers
0
Cytokines
0
Extracellular Matrix Proteins
0
Eye Proteins
0
tear proteins
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
6-14Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright 2019, SLACK Incorporated.