Reliability of the OptoJump Next System for Measuring Temporal Values in Elite Racewalking.


Journal

Journal of strength and conditioning research
ISSN: 1533-4287
Titre abrégé: J Strength Cond Res
Pays: United States
ID NLM: 9415084

Informations de publication

Date de publication:
Dec 2019
Historique:
pubmed: 15 1 2019
medline: 23 2 2020
entrez: 15 1 2019
Statut: ppublish

Résumé

Hanley, B and Tucker, CB. Reliability of the OptoJump Next system for measuring temporal values in elite racewalking. J Strength Cond Res 33(12): 3438-3443, 2019-Racewalking is an Olympic event where athletes are not permitted a visible loss of contact, with the result that competitors try to minimize flight times. The accuracy of measurements taken during testing is dependent on valid and reliable systems to determine temporal values. The aim of the study was to compare different methodologies used to measure contact and flight times in overground and treadmill racewalking. Eighteen racewalkers completed overground and instrumented treadmill trials at 5 speeds, during which flight and contact times were measured using the OptoJump Next photocell system (1,000 Hz), high-speed videography (500 Hz), and force plates (1,000 Hz). Results from OptoJump Next were extracted using 5 settings based on the number of light-emitting diodes (LEDs) activated (GaitIn_GaitOut) and annotated as 0_0, 1_1, 2_2, 3_3, and 4_4. Regarding flight time measurements for the overground condition, the 2_2 LED setting had the best 95% confidence interval (95% CI) for intraclass correlation coefficient (ICC) (0.978-0.988), the least bias (0.000 seconds), and the lowest random error (RE) (0.008 seconds). For the treadmill condition, the 0_0 LED setting had the best 95% CI for ICC (0.890-0.957), the least bias (0.004 seconds), and the lowest RE (0.017 seconds). Although high-speed videography also provided highly reliable results, the equally reliable and quicker availability of results using OptoJump Next is beneficial in laboratory-based testing. Coaches and researches are advised to alter the system's LED settings as appropriate and to report these settings with their findings.

Identifiants

pubmed: 30640307
doi: 10.1519/JSC.0000000000003008
doi:

Types de publication

Comparative Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

3438-3443

Auteurs

Brian Hanley (B)

Carnegie School of Sport, Leeds Beckett University, Leeds, United Kingdom.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH