Reproducibility and accuracy of late gadolinium enhancement cardiac magnetic resonance measurements for the detection of left atrial fibrosis in patients undergoing atrial fibrillation ablation procedures.
Atrial Fibrillation
/ pathology
Atrial Remodeling
Catheter Ablation
/ methods
Contrast Media
/ pharmacology
Female
Fibrosis
Gadolinium
/ pharmacology
Heart Atria
/ diagnostic imaging
Humans
Image Enhancement
/ methods
Magnetic Resonance Imaging
/ methods
Male
Middle Aged
Preoperative Care
/ methods
Reproducibility of Results
Ablation
Atrial fibrillation
Atrial fibrosis
Cardiac magnetic resonance
Delayed gadolinium enhancement
Reproducibility
Journal
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649
Informations de publication
Date de publication:
01 May 2019
01 May 2019
Historique:
received:
24
09
2018
accepted:
11
12
2018
pubmed:
17
1
2019
medline:
3
10
2020
entrez:
17
1
2019
Statut:
ppublish
Résumé
Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) may define left atrial (LA) anatomy and structural remodelling, and facilitate atrial fibrillation (AF) ablation. We aimed to assess the intra- and inter-observer reproducibility and agreement of LGE-CMR parameters with direct application to AF ablation techniques. One experienced and one non-experienced observer performed complete LGE-CMR data analysis twice, on different days, in 40 randomly selected LGE-CMR examinations [20 performed before ablation (pre-ablation) and 20 performed 3 months after ablation (post-ablation)]. Four additional observers (two experienced and two non-experienced) performed complete LGE-CMR data analysis in a subgroup of 30 patients (15 pre-ablation and 15 post-ablation). All LGE-CMR were performed in sinus rhythm. Intra- and inter-observer reproducibility of LA volume, LA area, and sphericity index (SI) was high: coefficient of variation <10% and intraclass correlation coefficient >0.71. Geometric congruency of repeated reconstruction of LA shape was high: maximal error <5 mm for intra-observer and <8 mm for inter-observer. The precision of scar location increased with extent of scar, and was high (Dice coefficient >0.75) when the scar area was >5 cm2 for a single observer and >15 cm2 for multiple observers. Non-experienced observers performed equally well to experienced observers. Late gadolinium enhancement cardiac magnetic resonance measurements of LA area, volume, and SI were reproducible, and geometric congruency of LA shape was high. Location of scar was precise for scar areas >5 cm2 for single observers and >15 cm2 for multiple observers, regardless of the observers' experience. These results may serve as a reference for future studies on the role for substrate-based AF ablation procedures.
Identifiants
pubmed: 30649273
pii: 5288125
doi: 10.1093/europace/euy314
doi:
Substances chimiques
Contrast Media
0
Gadolinium
AU0V1LM3JT
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
724-731Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.