Factors affecting adenoma detection rate in a national flexible sigmoidoscopy screening programme: a retrospective analysis.


Journal

The lancet. Gastroenterology & hepatology
ISSN: 2468-1253
Titre abrégé: Lancet Gastroenterol Hepatol
Pays: Netherlands
ID NLM: 101690683

Informations de publication

Date de publication:
03 2019
Historique:
received: 22 07 2018
revised: 10 11 2018
accepted: 12 11 2018
pubmed: 19 1 2019
medline: 2 6 2020
entrez: 19 1 2019
Statut: ppublish

Résumé

A national colorectal cancer screening programme started in England in 2013, offering one-off flexible sigmoidoscopy to all men and women aged 55 years in addition to the biennial faecal occult blood testing programme offered to all individuals aged 60-74 years. We analysed data from six pilot flexible sigmoidoscopy screening centres to examine factors affecting the adenoma detection rate (ADR). We did a retrospective analysis of flexible sigmoidoscopy screening procedures performed in individuals aged 55 years at six pilot sites in England as part of the National Health Service Bowel Scope Screening programme. ADR (number of procedures in which at least one adenoma was removed or biopsied, divided by total number of procedures) was calculated for each site and each endoscopist. Multiple regression models were used to examine the variation in ADR with withdrawal time and extent of examination, and the effect of other factors including comfort and bowel preparation on extent of examination. The analysis included 8256 procedures done between May 7, 2013, and May 6, 2014. The overall ADR was 9·1% (95% CI 8·5-9·8; 755 of 8256 procedures), varying from 7·4% (6·2-8·9) to 11·0% (9·1-13·4) by screening centre. The ADR was 11·5% (95% CI 10·6-12·5; 493 of 4299 procedures) in men and 6·6% (5·9-7·4; 262 of 3957 procedures) in women (p<0·0001). On multivariate analysis, factors associated with adenoma detection were male sex (relative risk 1·69, 95% CI 1·46-1·95; p<0·0001) and a withdrawal time from the splenic flexure of at least 3·25 min in negative procedures (1·22, 1·00-1·48; p=0·045). However, increasing the withdrawal time to 4·0 min or more did not increase the likelihood of adenoma detection (1·22, 0·99-1·51; p=0·057). Procedures not reaching the splenic flexure were associated with lower chance of adenoma detection (eg, 0·77, 0·66-0·91; p=0·0015 for procedures reaching the descending colon), but there was no additional benefit associated with reaching the transverse colon (0·83, 0·67-1·02; p=0·069). Women (0·83, 0·80-0·87; p<0·0001), individuals with adequate (0·79, 0·76-0·83; p<0·0001) or poor (0·58, 0·51-0·67; p<0·0001) bowel preparation (compared with good bowel preparation), and those with mild (0·82, 0·76-0·88; p<0·0001) or moderate or severe (0·58, 0·51-0·66; p<0·0001) discomfort (compared with no discomfort) were less likely to have a procedure reaching the splenic flexure. Key performance indicators for flexible sigmoidoscopy screening should be defined, including standards for insertion and withdrawal times, optimal depth, and bowel preparation. ADR could be improved by recommending a withdrawal time from the splenic flexure of at least 3·25 min (ideally 3·5-4·0 min). None.

Sections du résumé

BACKGROUND
A national colorectal cancer screening programme started in England in 2013, offering one-off flexible sigmoidoscopy to all men and women aged 55 years in addition to the biennial faecal occult blood testing programme offered to all individuals aged 60-74 years. We analysed data from six pilot flexible sigmoidoscopy screening centres to examine factors affecting the adenoma detection rate (ADR).
METHODS
We did a retrospective analysis of flexible sigmoidoscopy screening procedures performed in individuals aged 55 years at six pilot sites in England as part of the National Health Service Bowel Scope Screening programme. ADR (number of procedures in which at least one adenoma was removed or biopsied, divided by total number of procedures) was calculated for each site and each endoscopist. Multiple regression models were used to examine the variation in ADR with withdrawal time and extent of examination, and the effect of other factors including comfort and bowel preparation on extent of examination.
FINDINGS
The analysis included 8256 procedures done between May 7, 2013, and May 6, 2014. The overall ADR was 9·1% (95% CI 8·5-9·8; 755 of 8256 procedures), varying from 7·4% (6·2-8·9) to 11·0% (9·1-13·4) by screening centre. The ADR was 11·5% (95% CI 10·6-12·5; 493 of 4299 procedures) in men and 6·6% (5·9-7·4; 262 of 3957 procedures) in women (p<0·0001). On multivariate analysis, factors associated with adenoma detection were male sex (relative risk 1·69, 95% CI 1·46-1·95; p<0·0001) and a withdrawal time from the splenic flexure of at least 3·25 min in negative procedures (1·22, 1·00-1·48; p=0·045). However, increasing the withdrawal time to 4·0 min or more did not increase the likelihood of adenoma detection (1·22, 0·99-1·51; p=0·057). Procedures not reaching the splenic flexure were associated with lower chance of adenoma detection (eg, 0·77, 0·66-0·91; p=0·0015 for procedures reaching the descending colon), but there was no additional benefit associated with reaching the transverse colon (0·83, 0·67-1·02; p=0·069). Women (0·83, 0·80-0·87; p<0·0001), individuals with adequate (0·79, 0·76-0·83; p<0·0001) or poor (0·58, 0·51-0·67; p<0·0001) bowel preparation (compared with good bowel preparation), and those with mild (0·82, 0·76-0·88; p<0·0001) or moderate or severe (0·58, 0·51-0·66; p<0·0001) discomfort (compared with no discomfort) were less likely to have a procedure reaching the splenic flexure.
INTERPRETATION
Key performance indicators for flexible sigmoidoscopy screening should be defined, including standards for insertion and withdrawal times, optimal depth, and bowel preparation. ADR could be improved by recommending a withdrawal time from the splenic flexure of at least 3·25 min (ideally 3·5-4·0 min).
FUNDING
None.

Identifiants

pubmed: 30655218
pii: S2468-1253(18)30387-X
doi: 10.1016/S2468-1253(18)30387-X
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

239-247

Commentaires et corrections

Type : CommentIn

Informations de copyright

Copyright © 2019 Elsevier Ltd. All rights reserved.

Auteurs

Roisin Bevan (R)

North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK. Electronic address: roisinbevan@hotmail.com.

Roger G Blanks (RG)

Cancer Epidemiology Unit, University of Oxford, Oxford, UK.

Claire Nickerson (C)

NHS Cancer Screening Programmes, Sheffield, UK.

Brian P Saunders (BP)

St Mark's Hospital, London, UK.

John Stebbing (J)

Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK.

Richard Tighe (R)

Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK.

Andrew M Veitch (AM)

The Royal Wolverhampton NHS Trust, Wolverhampton, UK.

William Garrett (W)

Medway NHS Foundation Trust, Gillingham, UK.

Colin J Rees (CJ)

South Tyneside NHS Foundation Trust, South Shields, UK; Newcastle University, Newcastle-upon-Tyne, UK.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH