Lead extraction for reduction of chronic pain related to cardiovascular implantable electronic device.
Cardiovascular implantable electronic device
Cardiovascular implantable electronic device lead extraction
Chronic pain
Implantable cardioverter-defibrillator
Pacemaker
Journal
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649
Informations de publication
Date de publication:
01 May 2019
01 May 2019
Historique:
received:
24
08
2018
accepted:
20
12
2018
pubmed:
31
1
2019
medline:
3
10
2020
entrez:
31
1
2019
Statut:
ppublish
Résumé
Chronic pain at the cardiovascular implantable electronic device (CIED) generator or lead insertion site that is not otherwise manageable carries a IIA indication for extraction. However, limited data exist evaluating causes of pain and outcomes of extraction in eliminating pain. A multi-centre retrospective observational study was conducted to evaluate outcomes of patients undergoing device extraction for treatment of chronic device pain. Twenty-seven out of 2188 lead extraction candidates (1.3%) met the chronic pain IIA indication for extraction [50 ± 16 years; 14 (51%) women]. Onset, severity, triggers, and pain management were measured before and after extraction. Device type, procedure done (with/without reimplantation), and positive tissue cultures were noted. Pain was reported as constant (n = 14; 50%), intermittent (n = 13; 46%), and movement-triggered (n = 14; 50%). Average severity of pain was seven out of 10 (10 being the worst). Post-extraction, 18 (66%) received freedom from pain, including all patients with poorly formed pockets (n = 2) and subclinical infections (n = 2). Of the 18, 11 underwent reimplantation (61%) without recurrent pain. Nine still had pain (44 ± 17 years; seven women) after extraction. Eight of the nine underwent reimplantation, three on the contralateral chest wall and five ipsilaterally. Pain severity decreased (n = 5), increased (n = 1), or was unchanged (n = 3). Chronic pain at the CIED generator site can present as chronic or movement-triggered pain, and can be due to subclinical infection or a poorly formed device pocket. Extraction relieved constant and intermittent pain in two-thirds of patients. Extraction appears less successful in eliminating pain in women who undergo subsequent reimplantation.
Identifiants
pubmed: 30698694
pii: 5303686
doi: 10.1093/europace/euy320
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
781-786Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.