Automated Calculation of the Alberta Stroke Program Early CT Score: Feasibility and Reliability.


Journal

Radiology
ISSN: 1527-1315
Titre abrégé: Radiology
Pays: United States
ID NLM: 0401260

Informations de publication

Date de publication:
04 2019
Historique:
pubmed: 6 2 2019
medline: 24 12 2019
entrez: 6 2 2019
Statut: ppublish

Résumé

Background The Alberta Stroke Program Early CT Score (ASPECTS) evaluation is a qualitative method to evaluate focal hypoattenuation at brain CT in early acute stroke. However, interobserver agreement is only moderate. Purpose To compare ASPECTS calculated by using an automatic software tool to neuroradiologist evaluation in the setting of acute stroke. Materials and Methods For this retrospective study, consensus ASPECTS were defined by two neuroradiologists based on baseline noncontrast CTs collected from January 2017 to December 2017 from patients with an occlusion in the middle cerebral artery and from an additional cohort of patients suspected of having stroke and no large vessel occlusion. Imaging data from both baseline and follow-up CT was evaluated for the consensus reading. After 6 weeks, the same two neuroradiologists again determined ASPECTS by using only the baseline CT. For comparison, ASPECTS was also calculated from baseline CT images by using a commercially available software (RAPID ASPECTS). Both methods were compared by using weighted κ statistics. Results CT scans from 100 patients with middle cerebral artery occlusion (44 women [mean age ± standard deviation, 75 years ± 14] and 56 men [mean age, 71 years ± 14]) and 52 patients suspected of having stroke and no large vessel occlusion (19 women [mean age, 69 years ± 18] and 33 men [68 years ± 15]) were evaluated. Neuroradiologists showed moderate agreement with the consensus score (κ = 0.57 and κ = 0.56). Software analysis showed substantial agreement (κ = 0.9) with the consensus score. Software analysis showed a substantial agreement (κ = 0.78) after greater than 1 hour between symptom onset and imaging, which increased to high agreement (κ = 0.92) in the time window greater than 4 hours. The neuroradiologist raters did not achieve comparable results to the software until the time interval of greater than 4 hours (κ = 0.83 and κ = 0.76). Conclusion In acute stroke of the middle cerebral artery, the Alberta Stroke Program Early CT score calculated with automated software had better agreement than that of human readers with a predefined consensus score. © RSNA, 2019 Online supplemental material is available for this article.

Identifiants

pubmed: 30720400
doi: 10.1148/radiol.2019181228
doi:

Types de publication

Evaluation Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

141-148

Auteurs

Christian Maegerlein (C)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Johanna Fischer (J)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Sebastian Mönch (S)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Maria Berndt (M)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Silke Wunderlich (S)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Christian L Seifert (CL)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Manuel Lehm (M)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Tobias Boeckh-Behrens (T)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Claus Zimmer (C)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Benjamin Friedrich (B)

From the Department of Diagnostic and Interventional Neuroradiology (C.M., J.F., S.M., M.B., M.L., T.B.B., C.Z., B.F.) and Department of Neurology (S.W., C.L.S.), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str 22, 81675 Munich, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH