Performance and Usability of Three Systems for Continuous Glucose Monitoring in Direct Comparison.
CGM system
MARD
comparison study
continuous glucose monitoring
performance
usability
Journal
Journal of diabetes science and technology
ISSN: 1932-2968
Titre abrégé: J Diabetes Sci Technol
Pays: United States
ID NLM: 101306166
Informations de publication
Date de publication:
09 2019
09 2019
Historique:
pubmed:
8
2
2019
medline:
5
9
2020
entrez:
8
2
2019
Statut:
ppublish
Résumé
To be able to compare continuous glucose monitoring (CGM) systems, they have to be worn in parallel by the same subjects. This study evaluated the performance and usability of three different CGM systems in direct comparison. In this open, prospective study at two sites, 54 patients with diabetes wore three CGM systems each (Dexcom G5™ Mobile CGM system [DG5], Guardian™ Connect system [GC], and a Roche CGM system [RCGM]) in parallel for 6 or 7 days in a mixed inpatient and outpatient setting. Capillary comparison measurements were performed using a self-monitoring of blood glucose (SMBG) system. During study site visits, glucose excursions were induced. Performance of the systems was evaluated by calculating mean absolute relative differences (MARD, calculated as absolute differences for glucose concentrations <100 mg/dL and as relative differences for glucose concentrations ≥100 mg/dL), and mean relative differences (MRD, bias) between CGM and SMBG results. In addition, usability of the systems was assessed. Overall MARD was 10.1 ± 2.1 for DG5, 11.5 ± 4.2 for GC, and 11.9 ± 5.6 for RCGM. Performance improved in all systems after the first day of use. All systems showed >99% of values within zones A and B of the consensus error grid. Overall, all CGM systems showed a small negative bias compared to SMBG. Usability of the systems differed regarding patch adhesion rate, failure rate, and patient rating. Most patients preferred GC, but in general all systems were rated positively. All three CGM systems showed similar overall accuracy in this direct comparison, but small differences were observed with regard to specific glucose ranges and usability aspects.
Sections du résumé
BACKGROUND
To be able to compare continuous glucose monitoring (CGM) systems, they have to be worn in parallel by the same subjects. This study evaluated the performance and usability of three different CGM systems in direct comparison.
METHOD
In this open, prospective study at two sites, 54 patients with diabetes wore three CGM systems each (Dexcom G5™ Mobile CGM system [DG5], Guardian™ Connect system [GC], and a Roche CGM system [RCGM]) in parallel for 6 or 7 days in a mixed inpatient and outpatient setting. Capillary comparison measurements were performed using a self-monitoring of blood glucose (SMBG) system. During study site visits, glucose excursions were induced. Performance of the systems was evaluated by calculating mean absolute relative differences (MARD, calculated as absolute differences for glucose concentrations <100 mg/dL and as relative differences for glucose concentrations ≥100 mg/dL), and mean relative differences (MRD, bias) between CGM and SMBG results. In addition, usability of the systems was assessed.
RESULTS
Overall MARD was 10.1 ± 2.1 for DG5, 11.5 ± 4.2 for GC, and 11.9 ± 5.6 for RCGM. Performance improved in all systems after the first day of use. All systems showed >99% of values within zones A and B of the consensus error grid. Overall, all CGM systems showed a small negative bias compared to SMBG. Usability of the systems differed regarding patch adhesion rate, failure rate, and patient rating. Most patients preferred GC, but in general all systems were rated positively.
CONCLUSION
All three CGM systems showed similar overall accuracy in this direct comparison, but small differences were observed with regard to specific glucose ranges and usability aspects.
Identifiants
pubmed: 30730229
doi: 10.1177/1932296819826965
pmc: PMC6955463
doi:
Substances chimiques
Blood Glucose
0
Types de publication
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
890-898Références
Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37
pubmed: 28585879
Diabetes Technol Ther. 2015 Nov;17(11):787-94
pubmed: 26171659
J Diabetes Sci Technol. 2010 Jan 01;4(1):221-5
pubmed: 20167187
Diabetes Technol Ther. 2016 Feb;18 Suppl 2:S3-S13
pubmed: 26784127
Diabetes Technol Ther. 2016 Sep;18(9):561-7
pubmed: 27356172
J Diabetes Sci Technol. 2017 Nov;11(6):1147-1154
pubmed: 28486841
Diabetes Technol Ther. 2017 Nov;19(11):609-617
pubmed: 28829160
J Diabetes Sci Technol. 2013 Jul 01;7(4):815-23
pubmed: 23911162
Diabetes Care. 2008 Jun;31(6):1160-4
pubmed: 18339974
J Diabetes Sci Technol. 2013 Nov 01;7(6):1436-45
pubmed: 24351170
J Diabetes Sci Technol. 2017 Jul;11(4):833-838
pubmed: 28540756
Diabetes Care. 2000 Aug;23(8):1143-8
pubmed: 10937512
J Diabetes Sci Technol. 2016 Nov 1;10(6):1414-1415
pubmed: 27271844
Diabetes Obes Metab. 2015 Apr;17(4):343-9
pubmed: 25132320
Diabetes Technol Ther. 2014 Nov;16(11):759-67
pubmed: 25233297
J Diabetes Sci Technol. 2015 Sep 01;9(5):1030-40
pubmed: 26330485
J Diabetes Sci Technol. 2015 Mar;9(2):339-41
pubmed: 25385947
Diabetes Technol Ther. 2016 Aug;18(8):512-6
pubmed: 27472488
Diabetes Technol Ther. 2001 Fall;3(3):357-65
pubmed: 11762514
J Diabetes Sci Technol. 2013 Jul 01;7(4):842-53
pubmed: 23911165
Lancet. 2018 Apr 7;391(10128):1367-1377
pubmed: 29459019
J Diabetes Sci Technol. 2014 Jul;8(4):699-708
pubmed: 24876423
J Diabetes Sci Technol. 2015 Mar;9(2):209-14
pubmed: 25370149