Flow-controlled ventilation during ear, nose and throat surgery: A prospective observational study.
Journal
European journal of anaesthesiology
ISSN: 1365-2346
Titre abrégé: Eur J Anaesthesiol
Pays: England
ID NLM: 8411711
Informations de publication
Date de publication:
05 2019
05 2019
Historique:
pubmed:
8
2
2019
medline:
4
12
2019
entrez:
8
2
2019
Statut:
ppublish
Résumé
Flow-controlled ventilation (FCV) is a new mechanical ventilation mode that maintains constant flow during inspiration and expiration with standard tidal volumes via cuffed narrow-bore endotracheal tubes. Originating in manually operated 'expiratory ventilation assistance', FCV extends this technique by automatic control of airway flow, monitoring of intratracheal pressure and control of peak inspiratory pressure and end-expiratory pressure. FCV has not yet been described in a clinical study. The aim of this study was to provide an initial assessment of FCV in mechanically ventilated patients undergoing ear, nose and throat surgery and evaluate its potential for future use. An observational study. Two German academic medical centres from 24 November 2017 to 09 January 2018. Consecutive patients (≥ 18 years) scheduled for elective ear, nose and throat surgery. Exclusion criteria were planned laser surgery, intended fibreoptic awake intubation, emergency procedures, increased risk of aspiration, American Society of Anesthesiologists (ASA) physical status more than III and chronic obstructive pulmonary disease classified as GOLD stage more than II. Peri-operative use of FCV provided by a new type of ventilator (Evone) via a narrow-bore endotracheal tube (Tritube). Minute volume, respiratory rate, intratidal tracheal pressure amplitude (Δp) and end-tidal CO2 (PetCO2) were recorded every 5 min. All adverse events were noted. Data are presented as median [IQR]. Sixteen patients provided 15 evaluable data sets. A minute volume of 5.0 [4.4 to 6.4] l min and a respiratory rate of 9 [8 to 11] min generated a PetCO2 of 4.9 [4.8 to 5.0] kPa. Δp was 10 [9 to 12] cmH2O. Five adverse events were recorded: a tube obstruction due to airway secretions and four tube dislocations (two attributed to coughing, two not study-related). FCV achieves adequate PetCO2 levels with minute volume and Δp in the normal range. Tritube's high flow resistance may increase the likelihood of tube dislocations if the patient coughs. Although further evaluation is necessary, FCV provides a new option for short-term mechanical ventilation. The successful operation of FCV with narrow-bore tubes contributes to the armamentarium for airway management. DRKS00013312.
Sections du résumé
BACKGROUND
Flow-controlled ventilation (FCV) is a new mechanical ventilation mode that maintains constant flow during inspiration and expiration with standard tidal volumes via cuffed narrow-bore endotracheal tubes. Originating in manually operated 'expiratory ventilation assistance', FCV extends this technique by automatic control of airway flow, monitoring of intratracheal pressure and control of peak inspiratory pressure and end-expiratory pressure. FCV has not yet been described in a clinical study.
OBJECTIVE
The aim of this study was to provide an initial assessment of FCV in mechanically ventilated patients undergoing ear, nose and throat surgery and evaluate its potential for future use.
DESIGN
An observational study.
SETTING
Two German academic medical centres from 24 November 2017 to 09 January 2018.
PATIENTS
Consecutive patients (≥ 18 years) scheduled for elective ear, nose and throat surgery. Exclusion criteria were planned laser surgery, intended fibreoptic awake intubation, emergency procedures, increased risk of aspiration, American Society of Anesthesiologists (ASA) physical status more than III and chronic obstructive pulmonary disease classified as GOLD stage more than II.
INTERVENTION
Peri-operative use of FCV provided by a new type of ventilator (Evone) via a narrow-bore endotracheal tube (Tritube).
MAIN OUTCOME MEASURES
Minute volume, respiratory rate, intratidal tracheal pressure amplitude (Δp) and end-tidal CO2 (PetCO2) were recorded every 5 min. All adverse events were noted. Data are presented as median [IQR].
RESULTS
Sixteen patients provided 15 evaluable data sets. A minute volume of 5.0 [4.4 to 6.4] l min and a respiratory rate of 9 [8 to 11] min generated a PetCO2 of 4.9 [4.8 to 5.0] kPa. Δp was 10 [9 to 12] cmH2O. Five adverse events were recorded: a tube obstruction due to airway secretions and four tube dislocations (two attributed to coughing, two not study-related).
CONCLUSION
FCV achieves adequate PetCO2 levels with minute volume and Δp in the normal range. Tritube's high flow resistance may increase the likelihood of tube dislocations if the patient coughs. Although further evaluation is necessary, FCV provides a new option for short-term mechanical ventilation. The successful operation of FCV with narrow-bore tubes contributes to the armamentarium for airway management.
TRIAL REGISTRATION
DRKS00013312.
Identifiants
pubmed: 30730422
doi: 10.1097/EJA.0000000000000967
doi:
Types de publication
Journal Article
Multicenter Study
Observational Study
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM