A method for correcting breathing-induced field fluctuations in T2*-weighted spinal cord imaging using a respiratory trace.
7T MRI
T2* mapping
breathing-induced field fluctuations
multi-shot EPI
spinal cord imaging
Journal
Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245
Informations de publication
Date de publication:
06 2019
06 2019
Historique:
received:
31
08
2018
revised:
01
12
2018
accepted:
27
12
2018
pubmed:
10
2
2019
medline:
19
5
2020
entrez:
10
2
2019
Statut:
ppublish
Résumé
Spinal cord MRI at ultrahigh field is hampered by time-varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi-shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to correct the data at the image reconstruction level. The correction was demonstrated in the context of multi-shot T2*-weighted imaging of the cervical spinal cord at 7T. A respiratory trace was acquired during a high-resolution multi-echo gradient-echo sequence, used for structural imaging and quantitative T2* mapping, and a multi-shot EPI time series, as would be suitable for fMRI. The coupling between the trace and the breathing-induced fields was determined by a short calibration scan in each individual. Images were reconstructed with and without trace-based correction. In the multi-echo acquisition, breathing-induced fields caused severe ghosting in images with long TE, which led to a systematic underestimation of T2* in the spinal cord. The trace-based correction reduced the ghosting and increased the estimated T2* values. Breathing-related ghosting was also observed in the multi-shot EPI images. The correction largely removed the ghosting, thereby improving the temporal signal-to-noise ratio of the time series. Trace-based retrospective correction of breathing-induced field variations can reduce ghosting and improve quantitative metrics in multi-shot structural and functional T2*-weighted imaging of the spinal cord. The method is straightforward to implement and does not rely on sequence modifications or additional hardware beyond a respiratory bellows.
Identifiants
pubmed: 30737825
doi: 10.1002/mrm.27664
pmc: PMC6492127
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
3745-3753Subventions
Organisme : Wellcome Trust
ID : 202788/Z/16/Z
Pays : United Kingdom
Informations de copyright
© 2019 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Références
Neuroimage. 2016 Jun;133:31-40
pubmed: 26924285
Neuroimage. 2016 Dec;143:58-69
pubmed: 27574985
Neuroimage. 2010 Jul 1;51(3):1082-8
pubmed: 20338252
Semin Ultrasound CT MR. 2017 Apr;38(2):176-186
pubmed: 28347420
Magn Reson Med. 2019 Jun;81(6):3745-3753
pubmed: 30737825
J Magn Reson. 2011 Dec;213(2):533-41
pubmed: 22152368
Magn Reson Med. 2002 May;47(5):888-95
pubmed: 11979567
Magn Reson Med. 2016 Nov;76(5):1604-1611
pubmed: 27487798
Neuroimage. 2014 Sep;98:528-36
pubmed: 24780696
Neuroimage. 2018 Mar;168:437-451
pubmed: 28684332
Magn Reson Med. 2013 Mar 1;69(3):621-36
pubmed: 22570274
Neuroimage. 2018 Feb 15;167:191-202
pubmed: 29175497
NMR Biomed. 2012 Jul;25(7):891-9
pubmed: 22183956
Magn Reson Med. 2001 Oct;46(4):638-51
pubmed: 11590639
Magn Reson Med. 2015 May;73(5):1833-43
pubmed: 24903278
Magn Reson Med. 2017 Oct;78(4):1623-1634
pubmed: 27859558
Magn Reson Med. 2014 Jul;72(1):291-300
pubmed: 23963998
Magn Reson Med. 2007 Feb;57(2):362-8
pubmed: 17260378
Neuroimage. 2012 Apr 2;60(2):1538-49
pubmed: 22178812
Med Phys. 1996 Jun;23(6):815-50
pubmed: 8798169
Neuroimage. 2017 Jan 15;145(Pt A):24-43
pubmed: 27720818
Phys Med Biol. 2000 Dec;45(12):3809-20
pubmed: 11131201
Magn Reson Med. 2008 Jul;60(1):176-86
pubmed: 18581363
Radiology. 1994 Jul;192(1):117-21
pubmed: 8208922
Magn Reson Med. 2007 Jul;58(1):185-9
pubmed: 17659610
Elife. 2014 Aug 05;3:e02812
pubmed: 25097248
Magn Reson Med. 2018 Sep;80(3):935-946
pubmed: 29380427
Magn Reson Med. 2014 Dec;72(6):1629-36
pubmed: 24390654