Failure rates of mini-implants inserted in the retromolar area.
Adolescent
Bone Screws
/ statistics & numerical data
Dental Implantation, Endosseous
/ instrumentation
Dental Implants
/ statistics & numerical data
Equipment Failure
Equipment Failure Analysis
Female
Humans
Male
Mandible
/ pathology
Maxilla
/ pathology
Molar
Orthodontic Anchorage Procedures
/ instrumentation
Orthodontic Appliance Design
Retrospective Studies
Tooth Movement Techniques
/ instrumentation
Young Adult
Failure rate
Mini-implants rétromolaires
Mini-screws
Mini-vis
Retromolar mini-implants
TADS
Taux d’échec
Journal
International orthodontics
ISSN: 1879-680X
Titre abrégé: Int Orthod
Pays: France
ID NLM: 101184882
Informations de publication
Date de publication:
03 2019
03 2019
Historique:
pubmed:
17
2
2019
medline:
14
7
2020
entrez:
17
2
2019
Statut:
ppublish
Résumé
Anchorage reinforcement is an important issue in orthodontic treatment. There is a lack of evidence regarding the failure rate of mini-implants inserted in the retromolar (RM) area, therefore the purpose of this present study was to evaluate the failure rates of mini-implants inserted in the RM area and to evaluate the factors affecting their stability. This retrospective cohort study of 102 patients (52 female, 55 male; mean age: 18.6years; SD: 5.2years) that had received 110 RM mini-implants for orthodontic treatment from 1.2.2012 to 1.6.2017 was conducted after IRB approval at the department of orthodontics. Clinical notes and photographic images of the patients were analysed to evaluate the dependent and independent variables. The primary outcome was mini-implant failure. Independent variables of patient related factors, mini-implant related factors, orthodontic related factors, surgical related factors, and maintenance-related factors were evaluated by logistic regression models for association to failure rates. A 23.2% failure rate of mini-implants inserted in the RM area was observed. The patient's right side and inflammation were significantly associated with RM mini-implant failure. The odds ratios (relative risk) for mini-implant failure in the right side, and in mini-implants with inflammation around them were 0.166 and 0.188, respectively. Failure rate for RM mini-implants were found to be 23.2%. To minimize RM mini-implant failure, clinicians should attempt to reduce inflammation around the mini-implants, especially for mini-implants placed on the right RM area.
Identifiants
pubmed: 30770333
pii: S1761-7227(19)30006-3
doi: 10.1016/j.ortho.2019.01.006
pii:
doi:
Substances chimiques
Dental Implants
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
53-59Informations de copyright
Copyright © 2019 Elsevier Masson SAS. All rights reserved.