Navigation surgery using indocyanine green fluorescent imaging for hepatoblastoma patients.
Adult
Child
Coloring Agents
/ pharmacokinetics
Female
Hepatoblastoma
/ diagnostic imaging
Humans
Image Enhancement
/ methods
Indocyanine Green
/ pharmacokinetics
Liver
/ diagnostic imaging
Liver Neoplasms
/ diagnostic imaging
Male
Optical Imaging
/ methods
Reproducibility of Results
Retrospective Studies
Hepatoblastoma
Indocyanine green
Navigation surgery
Journal
Pediatric surgery international
ISSN: 1437-9813
Titre abrégé: Pediatr Surg Int
Pays: Germany
ID NLM: 8609169
Informations de publication
Date de publication:
May 2019
May 2019
Historique:
accepted:
08
02
2019
pubmed:
20
2
2019
medline:
14
6
2019
entrez:
20
2
2019
Statut:
ppublish
Résumé
Technology for detecting liver tumors and identifying the bile ducts using indocyanine green (ICG) has recently been developed. However, the usefulness and limitations of ICG navigation surgery for hepatoblastoma (HB) have not been fully clarified. We herein report our experiences with surgical navigation using ICG for in HB patients. In 5 HB patients, 10 ICG navigation surgeries were performed using a 10-mm infrared fluorescence imaging scope after the injection of 0.5 mg/kg ICG intravenously. The surgical and clinical features were collected retrospectively. Navigation surgery using ICG was performed for primary liver tumors in 4 cases, and the timing of ICG injection was 90.5 ± 33.7 h before the operation. All tumors exhibited intense fluorescence from the liver surface. ICG navigation for the primary liver tumor was useful for detecting the residual tumor at the stump and invasion to the diaphragm during surgery. Six lung surgeries using ICG navigation were performed. The timing of ICG injection was 21.8 ± 3.4 h before the operation. The size of the metastatic tumor was 7.4 ± 4.1 mm (1.2-15 mm). Of 11 metastatic tumors detected by computed tomography (CT), 10-including the smallest tumor (1.2 mm)-were able to be detected by ICG from the lung surface. The depth of the 10 ICG-positive tumors from the lung surface was 0.9 ± 1.9 mm (0-6 mm), and the depth of the single ICG-negative tumor was 12 mm. One lesion not detected by CT showed ICG false positivity. Navigation surgery using ICG for patients with HB was useful for identifying tumors and confirming complete resection. However, in ICG navigation surgery, we must be aware of the limitations with regard to the tumor size and the depth from the surface.
Sections du résumé
BACKGROUND
BACKGROUND
Technology for detecting liver tumors and identifying the bile ducts using indocyanine green (ICG) has recently been developed. However, the usefulness and limitations of ICG navigation surgery for hepatoblastoma (HB) have not been fully clarified. We herein report our experiences with surgical navigation using ICG for in HB patients.
METHODS
METHODS
In 5 HB patients, 10 ICG navigation surgeries were performed using a 10-mm infrared fluorescence imaging scope after the injection of 0.5 mg/kg ICG intravenously. The surgical and clinical features were collected retrospectively.
RESULTS
RESULTS
Navigation surgery using ICG was performed for primary liver tumors in 4 cases, and the timing of ICG injection was 90.5 ± 33.7 h before the operation. All tumors exhibited intense fluorescence from the liver surface. ICG navigation for the primary liver tumor was useful for detecting the residual tumor at the stump and invasion to the diaphragm during surgery. Six lung surgeries using ICG navigation were performed. The timing of ICG injection was 21.8 ± 3.4 h before the operation. The size of the metastatic tumor was 7.4 ± 4.1 mm (1.2-15 mm). Of 11 metastatic tumors detected by computed tomography (CT), 10-including the smallest tumor (1.2 mm)-were able to be detected by ICG from the lung surface. The depth of the 10 ICG-positive tumors from the lung surface was 0.9 ± 1.9 mm (0-6 mm), and the depth of the single ICG-negative tumor was 12 mm. One lesion not detected by CT showed ICG false positivity.
CONCLUSION
CONCLUSIONS
Navigation surgery using ICG for patients with HB was useful for identifying tumors and confirming complete resection. However, in ICG navigation surgery, we must be aware of the limitations with regard to the tumor size and the depth from the surface.
Identifiants
pubmed: 30778701
doi: 10.1007/s00383-019-04458-5
pii: 10.1007/s00383-019-04458-5
doi:
Substances chimiques
Coloring Agents
0
Indocyanine Green
IX6J1063HV
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
551-557Références
Breast Cancer. 2005;12(3):211-5
pubmed: 16110291
J Pediatr Surg. 2012 Dec;47(12):2194-8
pubmed: 23217875
J Pediatr Surg. 2013 Dec;48(12):2479-83
pubmed: 24314190
Pediatr Surg Int. 2015 Apr;31(4):407-11
pubmed: 25667048
J Pediatr Surg. 2015 May;50(5):833-6
pubmed: 25783395
J Pediatr Surg. 2015 Dec;50(12):2098-101
pubmed: 26388131
Asian J Endosc Surg. 2016 Nov;9(4):328-331
pubmed: 27251788
J Laparoendosc Adv Surg Tech A. 2017 Oct;27(10):1069-1073
pubmed: 28574801
J Pediatr Surg. 2017 Dec;52(12):2051-2055
pubmed: 28927977
J Laparoendosc Adv Surg Tech A. 2018 Sep;28(9):1152-1155
pubmed: 29906233
Hepatology. 1982 Jan-Feb;2(1):97-105
pubmed: 7054072