Predicted sediment toxicity downstream of combined sewer overflows corresponds with effects measured in two sediment contact bioassays.


Journal

Environmental pollution (Barking, Essex : 1987)
ISSN: 1873-6424
Titre abrégé: Environ Pollut
Pays: England
ID NLM: 8804476

Informations de publication

Date de publication:
May 2019
Historique:
received: 15 11 2018
revised: 07 02 2019
accepted: 23 02 2019
pubmed: 10 3 2019
medline: 10 7 2019
entrez: 10 3 2019
Statut: ppublish

Résumé

The present study investigated the sediment toxicity along 100 m transects downstream from three different combined sewer overflows (CSOs) using a coupled substance risk assessment and bioassay approach. As a first step, a risk assessment according to the consensus based sediment quality guideline was performed to estimate the probability for an incidence of toxicity to benthic organisms in freshwater sediments using their pollutant concentrations of metals, PAHs and PCBs. Secondly, two sediment contact assays (SCAs) using the nematode Caenorhabditis elegans and embryos of the fish Danio rerio were conducted. Sediments downstream from CSOs were strongly influenced by discharged particles in terms of pollution, due to associated contaminants as well as oxygen depletion caused by oxygen consuming matter. In general, the calculated probability for sediment toxicity corresponded with results of the SCAs. With increasing distance from the CSOs both the toxic potential of the sediments as well as their effects detected in the SCAs decreased. However, clear correlations between concentrations of metals as well as PCBs and toxic effects were found for the nematode SCA. The toxicity assay with embryos of D. rerio was strongly influenced by oxygen depletion in the sediments. Therefore, it was not possible to differentiate between responses mediated by pollution or oxygen depletion using the D. rerio embryo test. The results of the present study demonstrated a clear effect of CSOs on the toxicity of downstream located sediments. As particles were identified as vector for pollutants and as source for oxygen depletion, the retention of particles within the sewer network is of high importance to minimize both stressors. The present study shows that a retention zone located between the CSO and the receiving creek is an efficient measure to enhance sediment and water quality downstream of CSOs.

Identifiants

pubmed: 30851588
pii: S0269-7491(18)35146-7
doi: 10.1016/j.envpol.2019.02.079
pii:
doi:

Substances chimiques

Sewage 0
Water Pollutants, Chemical 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

782-791

Informations de copyright

Copyright © 2019 Elsevier Ltd. All rights reserved.

Auteurs

Gerhard Schertzinger (G)

Department of Aquatic Ecology and Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany. Electronic address: gerhard.schertzinger@uni-due.de.

Sonja Zimmermann (S)

Department of Aquatic Ecology and Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.

Bernd Sures (B)

Department of Aquatic Ecology and Centre for Water and Environmental Research (ZWU), University Duisburg-Essen, Universitätsstr. 2, 45141, Essen, Germany.

Articles similaires

Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice
Animals Tail Swine Behavior, Animal Animal Husbandry

Classifications MeSH