CT arthrography of the intra-articular long head of biceps tendon: Diagnostic performance outside the labral-bicipital complex.
Adolescent
Adult
Aged
Arthrography
Arthroscopy
Female
Humans
Male
Middle Aged
Retrospective Studies
Rupture
Sensitivity and Specificity
Shoulder Joint
/ diagnostic imaging
Tendinopathy
/ diagnostic imaging
Tendon Injuries
/ diagnostic imaging
Tendons
/ diagnostic imaging
Tomography, X-Ray Computed
Young Adult
Arthroscopy
Biceps long head
CT arthrography
Rotator cuff tears
Tendinopathy
Journal
Diagnostic and interventional imaging
ISSN: 2211-5684
Titre abrégé: Diagn Interv Imaging
Pays: France
ID NLM: 101568499
Informations de publication
Date de publication:
Historique:
received:
05
11
2018
revised:
22
01
2019
accepted:
05
02
2019
pubmed:
12
3
2019
medline:
30
1
2020
entrez:
12
3
2019
Statut:
ppublish
Résumé
The purpose of this study was to determine the performance of CT arthrography for the diagnosis of intra-articular long head of biceps (LHB) tendon intrinsic lesions using arthroscopy findings as standard of reference. CT arthrography studies of 98 patients (55 men, 43 women; mean age 54.8±12.7 [SD] years [range: 16-77 years]) were retrospectively evaluated by two radiologists independently. Per operative arthroscopic images and surgical reports were retrospectively reviewed by a shoulder-specialist surgeon. Based on the analysis of arthroscopic images and the surgical reports, the LHB tendon was classified as normal (continuous with uniform tendon thickness), tendinopathy/partial rupture (focal change in tendon thickness and contour irregularities) and total rupture (total loss in tendon continuity). Imaging results were compared to those of surgery that served as standard of reference. Interobserver agreement was assessed. At arthroscopy, the LHB tendon was classified as normal in 38/98 (38.8%) patients, tendinopathic in 51/52 (52%) and totally ruptured in 9/98 (9.2%). The sensitivity and specificity of CT arthrography for the diagnosis of LHB tendinopathy were respectively 74% (95%CI: 60%-85%) and 93% (95%CI: 80%-99%) for reader 1 and 79% (95% CI: 67%-89%) and 95% (95% CI: 83%-99%) for reader 2. The sensitivity and specificity for the diagnosis of LHB tendon total ruptures were 100% (95%CI: 66%-100%) and 93% (95%CI: 86%-98%) for both readers. Interobserver agreements for the identification of the LHB tendon tendinopathy and total ruptures were excellent (kappa values of 0.94 and 0.96, respectively). CT arthrography demonstrates good sensitivity and excellent specificity for the detection of intra-articular LHB tendinopathy and tear.
Identifiants
pubmed: 30853414
pii: S2211-5684(19)30037-3
doi: 10.1016/j.diii.2019.02.005
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
437-444Informations de copyright
Copyright © 2019 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.