CT arthrography of the intra-articular long head of biceps tendon: Diagnostic performance outside the labral-bicipital complex.


Journal

Diagnostic and interventional imaging
ISSN: 2211-5684
Titre abrégé: Diagn Interv Imaging
Pays: France
ID NLM: 101568499

Informations de publication

Date de publication:
Historique:
received: 05 11 2018
revised: 22 01 2019
accepted: 05 02 2019
pubmed: 12 3 2019
medline: 30 1 2020
entrez: 12 3 2019
Statut: ppublish

Résumé

The purpose of this study was to determine the performance of CT arthrography for the diagnosis of intra-articular long head of biceps (LHB) tendon intrinsic lesions using arthroscopy findings as standard of reference. CT arthrography studies of 98 patients (55 men, 43 women; mean age 54.8±12.7 [SD] years [range: 16-77 years]) were retrospectively evaluated by two radiologists independently. Per operative arthroscopic images and surgical reports were retrospectively reviewed by a shoulder-specialist surgeon. Based on the analysis of arthroscopic images and the surgical reports, the LHB tendon was classified as normal (continuous with uniform tendon thickness), tendinopathy/partial rupture (focal change in tendon thickness and contour irregularities) and total rupture (total loss in tendon continuity). Imaging results were compared to those of surgery that served as standard of reference. Interobserver agreement was assessed. At arthroscopy, the LHB tendon was classified as normal in 38/98 (38.8%) patients, tendinopathic in 51/52 (52%) and totally ruptured in 9/98 (9.2%). The sensitivity and specificity of CT arthrography for the diagnosis of LHB tendinopathy were respectively 74% (95%CI: 60%-85%) and 93% (95%CI: 80%-99%) for reader 1 and 79% (95% CI: 67%-89%) and 95% (95% CI: 83%-99%) for reader 2. The sensitivity and specificity for the diagnosis of LHB tendon total ruptures were 100% (95%CI: 66%-100%) and 93% (95%CI: 86%-98%) for both readers. Interobserver agreements for the identification of the LHB tendon tendinopathy and total ruptures were excellent (kappa values of 0.94 and 0.96, respectively). CT arthrography demonstrates good sensitivity and excellent specificity for the detection of intra-articular LHB tendinopathy and tear.

Identifiants

pubmed: 30853414
pii: S2211-5684(19)30037-3
doi: 10.1016/j.diii.2019.02.005
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

437-444

Informations de copyright

Copyright © 2019 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Auteurs

P A G Teixeira (PAG)

Service d'imagerie Guilloz, hôpital central, centre hospitalier universitaire de Nancy, 29, avenue du Maréchal de Lattre de Tassigny, 54035 Nancy, France. Electronic address: ped_gt@hotmail.com.

P Jaquet (P)

Service d'imagerie Guilloz, hôpital central, centre hospitalier universitaire de Nancy, 29, avenue du Maréchal de Lattre de Tassigny, 54035 Nancy, France.

O Bakour (O)

Service d'imagerie Guilloz, hôpital central, centre hospitalier universitaire de Nancy, 29, avenue du Maréchal de Lattre de Tassigny, 54035 Nancy, France.

A Jacquot (A)

Centre ARTIC•S, 24, rue du XXI régiment d'aviation, 54000 Nancy, France.

D Molé (D)

Centre ARTIC•S, 24, rue du XXI régiment d'aviation, 54000 Nancy, France.

F Sirveaux (F)

Centre chirurgical Emile-Gallé, 49, rue Hermite, 54000 Nancy, France.

A Blum (A)

Service d'imagerie Guilloz, hôpital central, centre hospitalier universitaire de Nancy, 29, avenue du Maréchal de Lattre de Tassigny, 54035 Nancy, France.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH