Non-uniform strain distribution in anterolateral capsule of knee: Implications for surgical repair.


Journal

Journal of orthopaedic research : official publication of the Orthopaedic Research Society
ISSN: 1554-527X
Titre abrégé: J Orthop Res
Pays: United States
ID NLM: 8404726

Informations de publication

Date de publication:
05 2019
Historique:
received: 06 05 2018
accepted: 15 11 2018
pubmed: 13 3 2019
medline: 21 12 2019
entrez: 13 3 2019
Statut: ppublish

Résumé

The existence of a ligamentous structure within the anterolateral capsule, which can be injured in combination with the anterior cruciate ligament, has been debated. Therefore, the purpose of this study was to determine the magnitude and direction of the strain in the anterolateral capsule in response to external loads applied to the knee. The anterolateral capsule was hypothesized to not function like a traditional ligament. A 6-degree-of-freedom robotic testing system was used to apply ten external loads to human cadaveric knees (n = 7) in the intact and anterior cruciate ligament (ACL) deficient states. The position of strain markers was recorded on the midsubstance of the anterolateral capsule during the resulting joint kinematics to determine the magnitude and direction of the maximum principal strain. The peak maximum principal strain ranged from 22% to 52% depending on the loading condition. When histograms of strain magnitude values were analyzed to determine strain uniformity, the mean kurtosis was 1.296 ± 0.955, lower than a typical ligament, and the mean variance was 0.015 ± 0.008, higher than a typical ligament. The mean angles of the strain direction vectors compared to the proposed ligament ranged between 38° and 130° (p < 0.05). The magnitude of the maximum principal strain in the anterolateral capsule is much larger than a typical ligament and does not demonstrate a uniform strain distribution. The direction of strain is also not aligned with the proposed ligament. Clinical Significance: Reconstruction methods using tendons will not produce normal joint function due to replacement of a multi-axial structure with a uni-axial structure. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

Identifiants

pubmed: 30859610
doi: 10.1002/jor.24270
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

1025-1032

Informations de copyright

© 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Auteurs

Daniel Guenther (D)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue, Pittsburgh, 15213, Pennsylvania.
Department of Orthopaedic Surgery, Trauma Surgery, and Sports Medicine, Cologne Merheim Medical Center, Witten/Herdecke University, Cologne, Germany.

Stephanie L Sexton (SL)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Bioengineering, University of Pittsburgh, Benedum Hall, 3700 O'Hara Street, Pittsburgh, 15261, Pennsylvania.

Kevin M Bell (KM)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Bioengineering, University of Pittsburgh, Benedum Hall, 3700 O'Hara Street, Pittsburgh, 15261, Pennsylvania.

Sebastián Irarrázaval (S)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue, Pittsburgh, 15213, Pennsylvania.

Freddie H Fu (FH)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue, Pittsburgh, 15213, Pennsylvania.

Volker Musahl (V)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue, Pittsburgh, 15213, Pennsylvania.
Department of Bioengineering, University of Pittsburgh, Benedum Hall, 3700 O'Hara Street, Pittsburgh, 15261, Pennsylvania.

Richard E Debski (RE)

Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, 15219, Pennsylvania.
Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue, Pittsburgh, 15213, Pennsylvania.
Department of Bioengineering, University of Pittsburgh, Benedum Hall, 3700 O'Hara Street, Pittsburgh, 15261, Pennsylvania.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH