Pipeline for Distal Cerebral Circulation Aneurysms.
Adult
Aged
Aged, 80 and over
Anterior Cerebral Artery
/ diagnostic imaging
Blood Vessel Prosthesis
Cerebrovascular Circulation
/ physiology
Embolization, Therapeutic
/ instrumentation
Female
Follow-Up Studies
Humans
Intracranial Aneurysm
/ diagnostic imaging
Male
Middle Aged
Posterior Cerebral Artery
/ diagnostic imaging
Retrospective Studies
Treatment Outcome
Distal Circulation
Flow Diversion
Pipeline
Journal
Neurosurgery
ISSN: 1524-4040
Titre abrégé: Neurosurgery
Pays: United States
ID NLM: 7802914
Informations de publication
Date de publication:
01 09 2019
01 09 2019
Historique:
received:
10
02
2018
accepted:
27
01
2019
pubmed:
21
3
2019
medline:
9
4
2020
entrez:
21
3
2019
Statut:
ppublish
Résumé
Pipeline embolization device (PED; Medtronic, Dublin, Ireland) utilization is not limited to the treatment of giant wide-necked aneurysms. It has been expanded to handle small blisters, fusiforms, and dissecting intracranial aneurysms. To report the use of the PED in various off-label distal cerebral circulation (DCC) arteries with a follow-up to assess clinical outcomes. Between 2011 and 2016, of 437 consecutive patients, 23 patients with aneurysms located in DCCs were treated with PED. Data on patient presentation, aneurysm characteristics, procedural outcomes, postoperative course, and aneurysm occlusion were gathered. To control confounding, we used multivariable logistic regression and propensity score conditioning. A total of 437 patients (mean age 52.12 years; 62 women [14.2%]) underwent treatment with PED in our institution. Twenty-three of 437 (5.2%) received a pipeline in a distal artery: 11/23 middle cerebral artery, 6/23 posterior cerebral artery, 3/23 anterior cerebral artery (A1/A2, pericallosal artery), and 3/23 posterior inferior cerebellar artery. Twenty percent of the aneurysms were treated in the past, 10% had previously ruptured, and 5.9% ruptured at presentation to our hospital. The mean aneurysm size was 9.0 ± 6 mm. The mean follow-up was 12 mo (SD = 12.5). In multivariable logistic regression, no associations were found between PED deployment in DCCs and aneurysm occlusion or thromboembolic complications. PED use in DCC was associated with a good clinical outcome. Twenty-two people of 23 (95%) had a good clinical outcome in the latest follow-up. Treatment of DCC aneurysms with PED is technically challenging mainly because of the small caliber and tortuosity of the parent arteries. The results of this study further support the safety of flow diverters in the treatment of various distal aneurysms.
Sections du résumé
BACKGROUND
Pipeline embolization device (PED; Medtronic, Dublin, Ireland) utilization is not limited to the treatment of giant wide-necked aneurysms. It has been expanded to handle small blisters, fusiforms, and dissecting intracranial aneurysms.
OBJECTIVE
To report the use of the PED in various off-label distal cerebral circulation (DCC) arteries with a follow-up to assess clinical outcomes.
METHODS
Between 2011 and 2016, of 437 consecutive patients, 23 patients with aneurysms located in DCCs were treated with PED. Data on patient presentation, aneurysm characteristics, procedural outcomes, postoperative course, and aneurysm occlusion were gathered. To control confounding, we used multivariable logistic regression and propensity score conditioning.
RESULTS
A total of 437 patients (mean age 52.12 years; 62 women [14.2%]) underwent treatment with PED in our institution. Twenty-three of 437 (5.2%) received a pipeline in a distal artery: 11/23 middle cerebral artery, 6/23 posterior cerebral artery, 3/23 anterior cerebral artery (A1/A2, pericallosal artery), and 3/23 posterior inferior cerebellar artery. Twenty percent of the aneurysms were treated in the past, 10% had previously ruptured, and 5.9% ruptured at presentation to our hospital. The mean aneurysm size was 9.0 ± 6 mm. The mean follow-up was 12 mo (SD = 12.5). In multivariable logistic regression, no associations were found between PED deployment in DCCs and aneurysm occlusion or thromboembolic complications. PED use in DCC was associated with a good clinical outcome. Twenty-two people of 23 (95%) had a good clinical outcome in the latest follow-up.
CONCLUSION
Treatment of DCC aneurysms with PED is technically challenging mainly because of the small caliber and tortuosity of the parent arteries. The results of this study further support the safety of flow diverters in the treatment of various distal aneurysms.
Identifiants
pubmed: 30892649
pii: 5398562
doi: 10.1093/neuros/nyz038
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
E477-E484Informations de copyright
Copyright © 2019 by the Congress of Neurological Surgeons.