Ability of an Arterial Waveform Analysis-Derived Hypotension Prediction Index to Predict Future Hypotensive Events in Surgical Patients.
Journal
Anesthesia and analgesia
ISSN: 1526-7598
Titre abrégé: Anesth Analg
Pays: United States
ID NLM: 1310650
Informations de publication
Date de publication:
02 2020
02 2020
Historique:
pubmed:
22
3
2019
medline:
22
4
2020
entrez:
22
3
2019
Statut:
ppublish
Résumé
Intraoperative hypotension is associated with worse perioperative outcomes for patients undergoing major noncardiac surgery. The Hypotension Prediction Index is a unitless number that is derived from an arterial pressure waveform trace, and as the number increases, the risk of hypotension occurring in the near future increases. We investigated the diagnostic ability of the Hypotension Prediction Index in predicting impending intraoperative hypotension in comparison to other commonly collected perioperative hemodynamic variables. This is a 2-center retrospective analysis of patients undergoing major surgery. Data were downloaded and analyzed from the Edwards Lifesciences EV1000 platform. Receiver operating characteristic curves were constructed for the Hypotension Prediction Index and other hemodynamic variables as well as event rates and time to event. Two hundred fifty-five patients undergoing major surgery were included in the analysis yielding 292,025 data points. The Hypotension Prediction Index predicted hypotension with a sensitivity and specificity of 85.8% (95% CI, 85.8%-85.9%) and 85.8% (95% CI, 85.8%-85.9%) 5 minutes before a hypotensive event (area under the curve, 0.926 [95% CI, 0.925-0.926]); 81.7% (95% CI, 81.6%-81.8%) and 81.7% (95% CI, 81.6%-81.8%) 10 minutes before a hypotensive event (area under the curve, 0.895 [95% CI, 0.894-0.895]); and 80.6% (95% CI, 80.5%-80.7%) and 80.6% (95% CI, 80.5%-80.7%) 15 minutes before a hypotensive event (area under the curve, 0.879 [95% CI, 0.879-0.880]). The Hypotension Prediction Index performed superior to all other measured hemodynamic variables including mean arterial pressure and change in mean arterial pressure over a 3-minute window. The Hypotension Prediction Index provides an accurate real time and continuous prediction of impending intraoperative hypotension before its occurrence and has superior predictive ability than the commonly measured perioperative hemodynamic variables.
Sections du résumé
BACKGROUND
Intraoperative hypotension is associated with worse perioperative outcomes for patients undergoing major noncardiac surgery. The Hypotension Prediction Index is a unitless number that is derived from an arterial pressure waveform trace, and as the number increases, the risk of hypotension occurring in the near future increases. We investigated the diagnostic ability of the Hypotension Prediction Index in predicting impending intraoperative hypotension in comparison to other commonly collected perioperative hemodynamic variables.
METHODS
This is a 2-center retrospective analysis of patients undergoing major surgery. Data were downloaded and analyzed from the Edwards Lifesciences EV1000 platform. Receiver operating characteristic curves were constructed for the Hypotension Prediction Index and other hemodynamic variables as well as event rates and time to event.
RESULTS
Two hundred fifty-five patients undergoing major surgery were included in the analysis yielding 292,025 data points. The Hypotension Prediction Index predicted hypotension with a sensitivity and specificity of 85.8% (95% CI, 85.8%-85.9%) and 85.8% (95% CI, 85.8%-85.9%) 5 minutes before a hypotensive event (area under the curve, 0.926 [95% CI, 0.925-0.926]); 81.7% (95% CI, 81.6%-81.8%) and 81.7% (95% CI, 81.6%-81.8%) 10 minutes before a hypotensive event (area under the curve, 0.895 [95% CI, 0.894-0.895]); and 80.6% (95% CI, 80.5%-80.7%) and 80.6% (95% CI, 80.5%-80.7%) 15 minutes before a hypotensive event (area under the curve, 0.879 [95% CI, 0.879-0.880]). The Hypotension Prediction Index performed superior to all other measured hemodynamic variables including mean arterial pressure and change in mean arterial pressure over a 3-minute window.
CONCLUSIONS
The Hypotension Prediction Index provides an accurate real time and continuous prediction of impending intraoperative hypotension before its occurrence and has superior predictive ability than the commonly measured perioperative hemodynamic variables.
Identifiants
pubmed: 30896602
doi: 10.1213/ANE.0000000000004121
doi:
Types de publication
Journal Article
Multicenter Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
352-359Commentaires et corrections