Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid and creatinine in porcine and broiler chicken plasma.
Chicken plasma
Creatinine
Iohexol
LC-MS/MS
Method development
Para-aminohippuric acid
Porcine plasma
Journal
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
ISSN: 1873-376X
Titre abrégé: J Chromatogr B Analyt Technol Biomed Life Sci
Pays: Netherlands
ID NLM: 101139554
Informations de publication
Date de publication:
01 Jun 2019
01 Jun 2019
Historique:
received:
21
02
2019
revised:
05
04
2019
accepted:
06
04
2019
pubmed:
21
4
2019
medline:
21
5
2019
entrez:
21
4
2019
Statut:
ppublish
Résumé
In order to study the renal function, in terms of glomerular filtration and effective renal plasma flow, in broiler chickens and pigs, an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid (PAH) and exogenously administered creatinine in plasma was developed and validated. Sample preparation consisted of a deproteinization step using methanol for porcine plasma and an Ostro™ Protein Precipitation & Phospholipid Removal Plate was used for broiler chicken plasma. Chromatographic separation was achieved on a Hypersil Gold aQ column using 0.1% formic acid in water and 0.1% formic acid in methanol as mobile phases. The total run time was limited to 10 min. Matrix-matched calibration curves for iohexol and PAH were prepared and good linearity (r ≥ 0.9973; gof ≤ 6.17%) was achieved over the concentration range tested (0.25-90 μg/mL). Limits of quantification were 0.25 μg/mL for iohexol and PAH. Water was used as surrogate matrix for analysis of creatinine in plasma. This surrogate calibration curve showed good linearity over the concentration range tested (0.25-90 μg/mL) (r ≥ 0.9979; gof ≤ 5.66%). For creatinine, the relative lower limit of quantification was 201.03 ± 49.20% and 60.14 ± 7.64% for chicken and porcine plasma, respectively. The results for within-day and between-day precision and accuracy fell within the specified ranges. This straightforward, cost-effective and rapid method, determining iohexol, PAH and creatinine within one single chromatographic run, has been successfully used for the analysis in porcine and broiler chicken plasma samples in order to determine the renal function of these species.
Identifiants
pubmed: 31004849
pii: S1570-0232(19)30296-X
doi: 10.1016/j.jchromb.2019.04.017
pii:
doi:
Substances chimiques
Iohexol
4419T9MX03
Creatinine
AYI8EX34EU
p-Aminohippuric Acid
Y79XT83BJ9
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
77-85Commentaires et corrections
Type : ErratumIn
Informations de copyright
Copyright © 2019. Published by Elsevier B.V.