Laparoscopic anatomical liver resection using indocyanine green fluorescence imaging.
Anatomical liver resection
Fluorescence imaging
Indocyanine green
Laparoscopic hepatectomy
Laparoscopic liver resection
Journal
Asian journal of surgery
ISSN: 0219-3108
Titre abrégé: Asian J Surg
Pays: Netherlands
ID NLM: 8900600
Informations de publication
Date de publication:
Jan 2020
Jan 2020
Historique:
received:
25
02
2019
revised:
22
03
2019
accepted:
11
04
2019
pubmed:
3
5
2019
medline:
20
9
2020
entrez:
3
5
2019
Statut:
ppublish
Résumé
Anatomical liver resections guided by a demarcation line after portal staining or inflow clamping of the target area have been established as essential methods for curative treatment of hepatocellular carcinoma (HCC) and have subsequently been applied to other malignancies. However, laparoscopic anatomical liver resection (LALR) procedures are very difficult to reproduce, and the confirmation of demarcation of the hepatic segment on a monitor is also challenging. Recently, indocyanine green (ICG) fluorescence imaging has been used to identify hepatic tumors and segmental boundaries during hepatectomy. Herein, we describe LALR using ICG fluorescence imaging. Three patients underwent pure LALR using ICG fluorescence imaging at our institute. One patient underwent anatomical partial liver resection for HCC, another underwent segmentectomy 3 for metastatic liver cancer, and the third underwent right anterior sectionectomy for HCC. To visualize hepatic perfusion and the demarcation line by negative staining using an optical imaging system, 2.5 mg ICG was injected intravenously during surgery following clamping or closure of the proximal Glissonean pedicles. For all three cases, ICG fluorescent imaging clearly delineated the demarcation lines and allowed identification of intersegmental planes to some extent because the tumor-bearing hepatic region became non-fluorescing parenchyma during parenchymal transection. This allowed surgeons to recognize the direction and guide the transection of the liver parenchyma when performing LALR. LALR using ICG fluorescence imaging is a feasible procedure for resection of the tumor-bearing hepatic region and facilitates visualization of the demarcation line and identification of the boundaries of the hepatic sections.
Sections du résumé
BACKGROUND
BACKGROUND
Anatomical liver resections guided by a demarcation line after portal staining or inflow clamping of the target area have been established as essential methods for curative treatment of hepatocellular carcinoma (HCC) and have subsequently been applied to other malignancies. However, laparoscopic anatomical liver resection (LALR) procedures are very difficult to reproduce, and the confirmation of demarcation of the hepatic segment on a monitor is also challenging. Recently, indocyanine green (ICG) fluorescence imaging has been used to identify hepatic tumors and segmental boundaries during hepatectomy. Herein, we describe LALR using ICG fluorescence imaging.
METHODS
METHODS
Three patients underwent pure LALR using ICG fluorescence imaging at our institute. One patient underwent anatomical partial liver resection for HCC, another underwent segmentectomy 3 for metastatic liver cancer, and the third underwent right anterior sectionectomy for HCC. To visualize hepatic perfusion and the demarcation line by negative staining using an optical imaging system, 2.5 mg ICG was injected intravenously during surgery following clamping or closure of the proximal Glissonean pedicles.
RESULTS
RESULTS
For all three cases, ICG fluorescent imaging clearly delineated the demarcation lines and allowed identification of intersegmental planes to some extent because the tumor-bearing hepatic region became non-fluorescing parenchyma during parenchymal transection. This allowed surgeons to recognize the direction and guide the transection of the liver parenchyma when performing LALR.
CONCLUSION
CONCLUSIONS
LALR using ICG fluorescence imaging is a feasible procedure for resection of the tumor-bearing hepatic region and facilitates visualization of the demarcation line and identification of the boundaries of the hepatic sections.
Identifiants
pubmed: 31043331
pii: S1015-9584(19)30220-9
doi: 10.1016/j.asjsur.2019.04.008
pii:
doi:
Substances chimiques
Indocyanine Green
IX6J1063HV
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
362-368Informations de copyright
Copyright © 2019. Published by Elsevier Taiwan LLC.