Comparison of the Accuracy of Newer Intraocular Lens Power Calculation Methods in Eyes That Underwent Previous Phototherapeutic Keratectomy.
Aged
Aged, 80 and over
Anterior Chamber
/ pathology
Axial Length, Eye
/ pathology
Biometry
/ methods
Cornea
/ physiopathology
Female
Humans
Lasers, Excimer
/ therapeutic use
Lens Implantation, Intraocular
Lenses, Intraocular
Male
Middle Aged
Optics and Photonics
Phacoemulsification
Photorefractive Keratectomy
Reproducibility of Results
Retrospective Studies
Journal
Journal of refractive surgery (Thorofare, N.J. : 1995)
ISSN: 1938-2391
Titre abrégé: J Refract Surg
Pays: United States
ID NLM: 9505927
Informations de publication
Date de publication:
01 May 2019
01 May 2019
Historique:
received:
23
11
2018
accepted:
09
04
2019
entrez:
7
5
2019
pubmed:
7
5
2019
medline:
9
11
2019
Statut:
ppublish
Résumé
To evaluate the accuracy of intraocular lens (IOL) power calculations using ray tracing software in patients who had undergone phototherapeutic keratectomy (PTK). In this retrospective case series, 37 eyes of 22 patients (mean age: 69.4 years; range: 56 to 85 years) who underwent cataract surgery after PTK were reviewed. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using the following formulas: OKULIX (Tedics, Dortmund, Germany), PhacoOptics (IOL Innovations ApS, Aarhus, Denmark), Barrett True K No History (NH), and Camellin-Calossi. The PhacoOptics formula was used in three different ways: historical method (H), no history method (NH), and C-constant method (C). The median values of the arithmetic and absolute prediction errors among these six IOL calculation methods were compared. The median arithmetic errors (in diopters [D]) and percentages of eyes within ±0.50 D of the absolute errors were as follows: OKULIX (0.33, range: -2.20 to 2.50, 30.6%), PhacoOptics (H) (-0.12, range: -3.28 to 4.85, 22.2%), PhacoOptics (NH) (-0.25, range: -2.08 to 1.70, 48.4%), PhacoOptics (C) (0.04, range: -1.40 to 2.18, 48.5%), Barrett True K (NH) (-0.35, range: -1.90 to 1.89, 48.6%), and Camellin-Calossi (-0.19, range: -1.78 to 1.47, 59.5%). The PhacoOptics, especially the C-constant method (C), and Camellin-Calossi formulas were good options for calculating IOL powers in eyes that underwent PTK. [J Refract Surg. 2019;35(5):310-316.].
Identifiants
pubmed: 31059580
doi: 10.3928/1081597X-20190410-01
doi:
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
310-316Informations de copyright
Copyright 2019, SLACK Incorporated.