Assessment of patient dose and noise level of clinical CT images: automated measurements.
Journal
Journal of radiological protection : official journal of the Society for Radiological Protection
ISSN: 1361-6498
Titre abrégé: J Radiol Prot
Pays: England
ID NLM: 8809257
Informations de publication
Date de publication:
Sep 2019
Sep 2019
Historique:
pubmed:
23
5
2019
medline:
21
7
2020
entrez:
23
5
2019
Statut:
ppublish
Résumé
We investigated comparisons between patient dose and noise in pelvic, abdominal, thoracic and head CT images using an automatic method. 113 patient images (37 pelvis, 34 abdominal, 25 thoracic, and 17 head examinations) were retrospectively and automatically examined in this study. Water-equivalent diameter (Dw), size-specific dose estimates (SSDE) and noise were automatically calculated from the center slice for every patient image. The Dw was calculated based on auto-contouring of the patients' edges, and the SSDE was calculated as the product of the volume CT dose index (CTDIvol) extracted from the Digital Imaging and Communications in Medicine (DICOM) header and the size conversion factor based on the Dw obtained from AAPM 204. The noise was automatically measured as a minimum standard deviation in the map of standard deviations. A square region of interest of about 1 cm
Identifiants
pubmed: 31117064
doi: 10.1088/1361-6498/ab23cc
doi:
Substances chimiques
Water
059QF0KO0R
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM