Evaluation of skin-mounted sensor for head impact measurement.


Journal

Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
ISSN: 2041-3033
Titre abrégé: Proc Inst Mech Eng H
Pays: England
ID NLM: 8908934

Informations de publication

Date de publication:
Jul 2019
Historique:
pubmed: 28 5 2019
medline: 26 11 2019
entrez: 25 5 2019
Statut: ppublish

Résumé

The requirement to measure the number and severity of head impacts in sports has led to the development of many wearable sensors. The objective of this study was to determine the reliability and accuracy of a wearable head impact sensor: xPatch, X2Biosystems, Inc. The skin-mounted sensor, xPatch, was fixed onto a Hybrid III headform and dropped using an impact test rig. A total of 400 impacts were performed, ranging from 20g to 200g linear acceleration, and impact velocities of 1.2 - 3.9 m/s. During each impact, the peak linear acceleration, angular velocity and angular acceleration were recorded and compared to the reference calibrated data. Impacts were also recorded using a high-speed video camera. The results show that the linear acceleration recorded by the xPatch during frontal and side impacts had errors of up to 24% when compared to the referenced data. The angular velocity and angular acceleration had substantially larger errors of up to 47.5% and 57%, respectively. The location of the impact had a significant effect on the results: if the impact was to the side of the head, the device on that side may have an error of up to 71%, thus highlighting the importance of device location. All impacts were recorded using two separate xPatches and, in certain cases, the difference in angular velocity between the devices was 43%. In conclusion, the xPatch can be useful for identifying impacts and recording linear accelerations during front and side impacts, but the rotational velocity and acceleration data need to be interpreted with caution.

Identifiants

pubmed: 31122140
doi: 10.1177/0954411919850961
doi:

Types de publication

Evaluation Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

735-744

Auteurs

Stephen Tiernan (S)

1 Technological University Dublin, Dublin, Ireland.

Gary Byrne (G)

1 Technological University Dublin, Dublin, Ireland.

David Michael O'Sullivan (DM)

2 Division of Sport Science, Pusan National University, Busan, Republic of Korea.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH