Implantable cardioverter-defibrillators in previously undiagnosed patients with catecholaminergic polymorphic ventricular tachycardia resuscitated from sudden cardiac arrest.
Catecholaminergic polymorphic ventricular tachycardia
Implantable cardioverter-defibrillator
Secondary prevention
Sudden cardiac arrest
Sudden cardiac death
Journal
European heart journal
ISSN: 1522-9645
Titre abrégé: Eur Heart J
Pays: England
ID NLM: 8006263
Informations de publication
Date de publication:
14 09 2019
14 09 2019
Historique:
received:
05
01
2019
revised:
28
03
2019
accepted:
26
04
2019
pubmed:
31
5
2019
medline:
6
11
2020
entrez:
31
5
2019
Statut:
ppublish
Résumé
In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), implantable cardioverter-defibrillator (ICD) shocks are sometimes ineffective and may even trigger fatal electrical storms. We assessed the efficacy and complications of ICDs placed in patients with CPVT who presented with a sentinel event of sudden cardiac arrest (SCA) while undiagnosed and therefore untreated. We analysed 136 patients who presented with SCA and in whom CPVT was diagnosed subsequently, leading to the initiation of guideline-directed therapy, including β-blockers, flecainide, and/or left cardiac sympathetic denervation. An ICD was implanted in 79 patients (58.1%). The primary outcome of the study was sudden cardiac death (SCD). The secondary outcomes were composite outcomes of SCD, SCA, appropriate ICD shocks, and syncope. After a median follow-up of 4.8 years, SCD had occurred in three patients (3.8%) with an ICD and none of the patients without an ICD (P = 0.1). SCD, SCA, or appropriate ICD shocks occurred in 37 patients (46.8%) with an ICD and 9 patients (15.8%) without an ICD (P < 0.0001). Inappropriate ICD shocks occurred in 19 patients (24.7%) and other device-related complications in 22 patients (28.9%). In previously undiagnosed patients with CPVT who presented with SCA, an ICD was not associated with improved survival. Instead, the ICD was associated with both a high rate of appropriate ICD shocks and inappropriate ICD shocks along with other device-related complications. Strict adherence to guideline-directed therapy without an ICD may provide adequate protection in these patients without all the potential disadvantages of an ICD.
Identifiants
pubmed: 31145795
pii: 5506735
doi: 10.1093/eurheartj/ehz309
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
2953-2961Commentaires et corrections
Type : CommentIn
Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.