Three-year clinical and two-year multimodality imaging outcomes of a thin-strut sirolimus-eluting bioresorbable vascular scaffold: MeRes-1 trial.
Absorbable Implants
Cardiovascular Agents
/ administration & dosage
Coronary Angiography
Coronary Artery Disease
/ diagnostic imaging
Coronary Vessels
/ diagnostic imaging
Drug-Eluting Stents
Everolimus
/ administration & dosage
Follow-Up Studies
Humans
India
Percutaneous Coronary Intervention
/ adverse effects
Sirolimus
/ administration & dosage
Treatment Outcome
Journal
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
ISSN: 1969-6213
Titre abrégé: EuroIntervention
Pays: France
ID NLM: 101251040
Informations de publication
Date de publication:
20 Sep 2019
20 Sep 2019
Historique:
pubmed:
31
5
2019
medline:
2
10
2019
entrez:
1
6
2019
Statut:
ppublish
Résumé
Although the proof of concept of the bioresorbable vascular scaffold (BRS) is well documented, device-related adverse outcomes with first-generation BRS indicate longer-term surveillance. The current study provides insights into the safety and performance of the MeRes100, a novel second-generation sirolimus-eluting BRS, beyond one-year up to three-year follow-up (FU). A total of 108 enrolled patients with de novo coronary artery lesions who underwent implantation of MeRes100 as part of the first-in-human MeRes-1 trial were followed up clinically beyond one year at two and three years and with multiple modality imaging at six months and two years. At three-year FU, the cumulative major adverse cardiac events rate was 1.87%, in the form of two ischaemia-driven target lesion revascularisations. No scaffold thrombosis was reported. Between six months and two years at quantitative coronary angiography, in-segment late lumen loss (LLL) (0.15±0.22 mm vs. 0.23±0.32 mm; p=0.18) and in-scaffold LLL (0.13±0.22 mm vs. 0.24±0.34 mm; p=0.10) changed insignificantly. IVUS subset analysis revealed a non-significant reduction in mean lumen area (6.17±1.28 mm2 vs. 5.47±1.50 mm2; p=0.21) and minimum lumen area (5.14±1.19 mm2 vs. 4.05±1.42 mm2; p=0.10) at two years compared to post-procedural measurements. OCT subset analysis demonstrated 99.24±2.27% neointimal strut coverage. The extended outcomes of the MeRes-1 trial demonstrated sustained efficacy and safety of the MeRes100 BRS with maintained lumen patency up to two years by multimodality imaging and no very late scaffold thrombosis up to three-year clinical FU.The MeRes-1 trial is registered at the Clinical Trials Registry-India. CTRI Number: CTRI/2015/04/005706.
Identifiants
pubmed: 31147308
pii: EIJ-D-19-00324
doi: 10.4244/EIJ-D-19-00324
pii:
doi:
Substances chimiques
Cardiovascular Agents
0
Everolimus
9HW64Q8G6G
Sirolimus
W36ZG6FT64
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM