Performance of a Dual Human Immunodeficiency Virus/Syphilis Rapid Test Compared With Conventional Serological Testing for Syphilis and Human Immunodeficiency Virus in a Laboratory Setting: Results From the Zimbabwe STI Etiology Study.
Adolescent
Adult
Antibodies, Bacterial
/ blood
Clinical Laboratory Techniques
/ methods
Female
HIV
HIV Infections
/ blood
Humans
Male
Middle Aged
Point-of-Care Testing
/ standards
Reagent Kits, Diagnostic
/ standards
Sensitivity and Specificity
Serologic Tests
/ standards
Syphilis
/ blood
Syphilis Serodiagnosis
/ methods
Treponema pallidum
Young Adult
Zimbabwe
Journal
Sexually transmitted diseases
ISSN: 1537-4521
Titre abrégé: Sex Transm Dis
Pays: United States
ID NLM: 7705941
Informations de publication
Date de publication:
09 2019
09 2019
Historique:
pubmed:
11
6
2019
medline:
27
6
2020
entrez:
11
6
2019
Statut:
ppublish
Résumé
Dual human immunodeficiency virus (HIV)/syphilis rapid, point-of-care testing may enhance syphilis screening among high-risk populations, increase case finding, reduce time to treatment, and prevent complications. We assessed the laboratory-based performance of a rapid dual HIV/syphilis test using serum collected from patients enrolled in the Zimbabwe Sexually Transmitted Infections (STI) Etiology study. Blood specimens were collected from patients presenting with STI syndromes in 6, predominantly urban STI clinics in different regions of Zimbabwe. All specimens were tested at a central research laboratory using the Standard Diagnostics Bioline HIV/Syphilis Duo test. The treponemal syphilis component of the dual rapid test was compared with the Treponema pallidum hemagglutination assay (TPHA) as a gold standard comparator, both alone or in combination with a nontreponemal test, the rapid plasma reagin test. The HIV component of the dual test was compared with a combination of HIV rapid tests conducted at the research laboratory following the Zimbabwe national HIV testing algorithm. Of 600 men and women enrolled in the study, 436 consented to serological syphilis and HIV testing and had specimens successfully tested by all assays. The treponemal component of the dual test had a sensitivity of 66.2% (95% confidence interval [CI], 55.2%-77.2%) and a specificity of 96.4% (95% CI, 94.5%-98.3%) when compared with TPHA; the sensitivity increased to 91.7% (95% CI, 82.6%-99.9%) when both TPHA and rapid plasma reagin were positive. The HIV component of the dual test had a sensitivity of 99.4% (95% CI, 98.4%-99.9%) and a specificity of 100% (95% CI, 99.9%-100%) when compared with the HIV testing algorithm. Laboratory performance of the SD Bioline HIV/Syphilis Duo test was high for the HIV component of the test. Sensitivity of the treponemal component was lower than reported from most laboratory-based evaluations in the literature. However, sensitivity of the test increased substantially among patients more likely to have active syphilis for which results of both standard treponemal and nontreponemal tests were positive.
Sections du résumé
BACKGROUND
Dual human immunodeficiency virus (HIV)/syphilis rapid, point-of-care testing may enhance syphilis screening among high-risk populations, increase case finding, reduce time to treatment, and prevent complications. We assessed the laboratory-based performance of a rapid dual HIV/syphilis test using serum collected from patients enrolled in the Zimbabwe Sexually Transmitted Infections (STI) Etiology study.
METHODS
Blood specimens were collected from patients presenting with STI syndromes in 6, predominantly urban STI clinics in different regions of Zimbabwe. All specimens were tested at a central research laboratory using the Standard Diagnostics Bioline HIV/Syphilis Duo test. The treponemal syphilis component of the dual rapid test was compared with the Treponema pallidum hemagglutination assay (TPHA) as a gold standard comparator, both alone or in combination with a nontreponemal test, the rapid plasma reagin test. The HIV component of the dual test was compared with a combination of HIV rapid tests conducted at the research laboratory following the Zimbabwe national HIV testing algorithm.
RESULTS
Of 600 men and women enrolled in the study, 436 consented to serological syphilis and HIV testing and had specimens successfully tested by all assays. The treponemal component of the dual test had a sensitivity of 66.2% (95% confidence interval [CI], 55.2%-77.2%) and a specificity of 96.4% (95% CI, 94.5%-98.3%) when compared with TPHA; the sensitivity increased to 91.7% (95% CI, 82.6%-99.9%) when both TPHA and rapid plasma reagin were positive. The HIV component of the dual test had a sensitivity of 99.4% (95% CI, 98.4%-99.9%) and a specificity of 100% (95% CI, 99.9%-100%) when compared with the HIV testing algorithm.
CONCLUSIONS
Laboratory performance of the SD Bioline HIV/Syphilis Duo test was high for the HIV component of the test. Sensitivity of the treponemal component was lower than reported from most laboratory-based evaluations in the literature. However, sensitivity of the test increased substantially among patients more likely to have active syphilis for which results of both standard treponemal and nontreponemal tests were positive.
Identifiants
pubmed: 31181033
doi: 10.1097/OLQ.0000000000001022
doi:
Substances chimiques
Antibodies, Bacterial
0
Reagent Kits, Diagnostic
0
Types de publication
Comparative Study
Journal Article
Research Support, U.S. Gov't, P.H.S.
Langues
eng
Sous-ensembles de citation
IM
Pagination
584-587Subventions
Organisme : PEPFAR
Pays : United States