Minimal Clinically Important Difference and Substantial Clinical Benefit Values for a Pain Visual Analog Scale After Hip Arthroscopy.
Journal
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
ISSN: 1526-3231
Titre abrégé: Arthroscopy
Pays: United States
ID NLM: 8506498
Informations de publication
Date de publication:
07 2019
07 2019
Historique:
received:
14
09
2018
revised:
12
02
2019
accepted:
17
02
2019
pubmed:
19
6
2019
medline:
6
5
2020
entrez:
19
6
2019
Statut:
ppublish
Résumé
To define minimal clinically important difference (MCID) and substantial clinical benefit (SCB) values for a pain visual analog scale (VAS) in patients undergoing hip arthroscopy for femoroacetabular impingement or chondrolabral pathology. This was a retrospective review of prospective collected data on patients having hip arthroscopy for femoroacetabular impingement and/or chondrolabral pathology. On initial assessment and follow-up between 335 and 395 days postsurgery, subjects completed a pain VAS and categorical self-rating of function. MCID was calculated using one-half the standard deviation (SD) of the change in 1-year pain VAS values. Receiver operator characteristic analysis was performed to determine SCB values. A change in SCB value was determined based on change in categorical self-rating of function to create "improved" and "not improved" groups. Absolute postoperative SCB scores were calculated to determine scores that would be associated with "normal" or "abnormal" function ratings. Of 1,034 eligible patients, 733 (71%) met the inclusion criteria, with 537 (73%) women and 196 (27%) men having a mean age of 35.3 years (SD 13). At a mean of 352 (SD 21) days postsurgery, 536 (73%) were in the improved group and 197 (27%) in the not improved group. MCID was -15.0 mm. A change of -22.7 mm on the pain VAS was able to identify those that improved with high sensitivity (0.74) and specificity (0.63). Values of ≤10.4 mm and ≥29.0 mm were cutoffs identifying subjects that rated their function as normal or abnormal, respectively, with high sensitivity (0.79 and 0.76) and specificity (0.88 and 0.76). This study provides surgeons with information to help interpret pain VAS values at a follow-up period ranging from 335 to 395 days with MCID and SCB values of -15.0 mm and -22.7 mm, respectively. Additionally, a patient who assesses a pain level at ≤10.4 mm is likely to have a normal rating of function, whereas a patient who assesses a pain level at ≥29.0 mm is likely to have an abnormal rating of function. III, retrospective comparative study.
Identifiants
pubmed: 31208920
pii: S0749-8063(19)30190-2
doi: 10.1016/j.arthro.2019.02.032
pii:
doi:
Types de publication
Journal Article
Multicenter Study
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
2064-2069Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright © 2019. Published by Elsevier Inc.