A Technical Note on Making Patient-Specific Pedicle Screw Templates for Revision Pediatric Kyphoscoliosis Surgery with Sublaminar Wires In Situ.

Kyphoscoliosis pedicle screw templates revision surgery three-dimensional printing

Journal

Journal of orthopaedic case reports
ISSN: 2250-0685
Titre abrégé: J Orthop Case Rep
Pays: India
ID NLM: 101641392

Informations de publication

Date de publication:
Historique:
entrez: 28 6 2019
pubmed: 28 6 2019
medline: 28 6 2019
Statut: ppublish

Résumé

Revision deformity correction surgery of a pediatric spine, especially with sublaminar Soacing between wires in situ, is a daunting task for patient as well as treating physician. Obscured native anatomy in the presence of sublaminar wires poses a staunch intraoperative challenge for a surgeon for safe placement of pedicle screws so as to avoid neurological and vascular injury. In revision surgeries with previous implants, it' is challenging, especially due to metal artifacts in imaging, bone loss due to previous surgery. In this note, we describe the technique of making making three-dimensional (3D)-printed patient-specific templates for safe placement of pedicle screws in pediatric patients undergoing revision kyphoscoliosis surgery with sublaminar wires in situ. A 12-year-old female presented to the clinic with a history of early-onset scoliosis, for which she underwent deformity correction surgery with spinal rectangle loop and sublaminar wires 4 years ago. At presentation, she had decompensated with increase in deformity and failed implant. She underwent revision deformity correction surgery with pedicle screws. 3D-printed patient-specific pedicle screw templates were useful in this patient for appropriate pedicle screw placement, as patient had obscured native anatomy due to fusion mass and in situ sublaminar wires. 3D-printed patient-specific pedicle screw templates are very useful in revision pediatric deformity correction surgeries, especially when the obscured native bony anatomy makes free-hand insertion of pedicle screw unsafe.

Identifiants

pubmed: 31245327
doi: 10.13107/jocr.2250-0685.1320
pii: JOCR-9-82
pmc: PMC6588152
doi:

Types de publication

Case Reports

Langues

eng

Pagination

82-84

Déclaration de conflit d'intérêts

Conflict of Interest: Nil

Références

Spine (Phila Pa 1976). 2001 Sep 1;26(17):1920-6
pubmed: 11568706
Spine (Phila Pa 1976). 2005 Dec 15;30(24):2841-5
pubmed: 16371915
Spine (Phila Pa 1976). 2006 Dec 15;31(26):3018-26
pubmed: 17172999
Int J Comput Assist Radiol Surg. 2010 Jul;5(4):335-41
pubmed: 20467825
JAMA. 2014 Dec 3;312(21):2213-4
pubmed: 25461994
Eur Spine J. 2016 Jun;25(6):1698-705
pubmed: 25820409
Eur Spine J. 2017 Jun;26(6):1684-1689
pubmed: 28028644
Spine (Phila Pa 1976). 1997 Oct 1;22(19):2239-45
pubmed: 9346144

Auteurs

Akshay Gadiya (A)

Department of Orthopaedics, The Spine Clinic, Lilavati Hospital and Research Center, Mumbai, Maharashtra, India.

Kunal Shah (K)

"Spine and Pain Clinic", LBS Road, Ghatkopar West, Mumbai, Maharashtra, India.

Premik Nagad (P)

Department of Orthopaedics, The Spine Clinic, Lilavati Hospital and Research Center, Mumbai, Maharashtra, India.

Abhay Nene (A)

Department of Orthopaedics, The Spine Clinic, Lilavati Hospital and Research Center, Mumbai, Maharashtra, India.