Five-year study of mandibular overdentures on stud abutments: Clinical outcome, patient satisfaction and prosthetic maintenance-Influence of bone resorption and implant position.


Journal

Clinical oral implants research
ISSN: 1600-0501
Titre abrégé: Clin Oral Implants Res
Pays: Denmark
ID NLM: 9105713

Informations de publication

Date de publication:
Sep 2019
Historique:
received: 04 03 2019
revised: 18 06 2019
accepted: 18 06 2019
pubmed: 3 7 2019
medline: 23 10 2019
entrez: 3 7 2019
Statut: ppublish

Résumé

This prospective study analyses the 5-year clinical outcome, patient satisfaction and the technical outcome of a 2-implant overdenture on stud abutments. In addition, the influence of mandibular resorption and implant position on these outcomes was assessed. Patients received two implants in a one-stage delayed protocol. Final prosthesis on stud abutments was finalized after 3 months. Implant survival, bone loss, plaque and sulcus bleeding index, OHIP-14, technical outcome and costs were assessed after 5 years. The Cawood-Howell classification defined the mandibular resorption. Inter-implant distances and angles (frontal, sagittal) were digitally measured. The significance level was p < .05. Fifty-six patients, 23 female and 33 males (mean age = 66.3, range 41-82), completed the follow-up. No implants were lost. Radiographical crestal bone loss was on average 1.25 mm (standard deviation SD 1.06), bleeding index was 0.75 (SD 0.73), and plaque index was 1.15 (SD 0.75) and higher for low mandibles (p = .001). The OHIP-14 reduction post-connection and after 5 years was significant (p < .001). Five-year maintenance required on average 6.7 (SD 4.8, range 0-25) interventions per patient. A larger inter-implant distance was associated with fewer replacement of retention inserts (p = .034) and less interventions (p = .006). Larger frontal (p = .023) and sagittal (p = .046) inter-implant angles (non-parallelism) required more inserts. The maintenance cost negatively influences the patient satisfaction (p = .004). 83% of the stud abutments showed wear. The implant overdenture on cylindrical stud abutments is a good and stable solution, irrespective of the resorption profile of the mandible. OHIP-14 improved permanently up to 5 years but is negatively influenced by complication cost. A small inter-implant distance, more frontal, sagittal inter-implant divergence increased maintenance.

Identifiants

pubmed: 31264259
doi: 10.1111/clr.13501
doi:

Substances chimiques

Dental Implants 0

Types de publication

Journal Article

Langues

eng

Pagination

940-951

Informations de copyright

© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Références

Alfadda, S. A., Al Amri, M. D., Al-Ohali, A., Al-Hakami, A., & Al-Madhi, N. (2017). Two-implant-supported mandibular overdentures: Do clinical denture quality and inter-implant distance affect patient satisfaction? International Journal of Prosthodontics, 30, 519-525. https://doi.org/10.11607/ijp.5295
Alvarez-Arenal, A., Gonzalez-Gonzalez, I., deLlanos-Lanchares, H., Martin-Fernandez, E., Brizuela-Velasco, A., & Ellacuria-Echebarria, J. (2017). Effect of implant-and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study. Journal of Advanced Prosthodontics, 9, 371-380. https://doi.org/10.4047/jap.2017.9.5.371
Aroso, C., Silva, A. S., Ustrell, R., Mendes, J. M., Braga, A. C., Berastegui, E., & Escuin, T. (2016). Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study. Journal of Advanced Prosthodontics, 8, 21-29. https://doi.org/10.4047/jap.2016.8.1.21
Assaf, A., Daas, M., Boittin, A., Eid, N., & Postaire, M. (2017). Prosthetic maintenance of different mandibular implant overdentures: A systematic review. Journal of Prosthetic Dentistry, 118, 144-152.e5. https://doi.org/10.1016/j.prosdent.2016.10.037
Bilhan, H., Geckili, O., Sulun, T., & Bilgin, T. (2011). A quality-of-life comparison between self-aligning and ball attachment systems for 2-implant-retained mandibular overdentures. Journal of Oral Implantology, 37(sp1), 167-173. https://doi.org/10.1563/AAID-JOI-D-10-00070
Bonnet, A. S., Dubois, G., Daas, M., & Lipinski, P. (2008). Influence of implant position on the behaviour of a mandibular implant-retained overdenture. Journal of Biomechanics, 41, https://doi.org/10.1016/S0021-9290(08)70218-5
Cawood, J. I., & Howell, R. A. (1988). A classification of the edentulous jaws. International Journal of Oral and Maxillofacial Surgery, 17(4), 232-236. https://doi.org/10.1016/S0901-5027(88)80047-X
Choi, J. W., Yun, B. H., Jeong, C. M., & Huh, J. B. (2018). Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures. The International Journal of Oral and Maxillofacial Implants, 33, 1079-1088. https://doi.org/10.11607/jomi.6023
Cristache, C. M., Muntianu, L. A., Burlibasa, M., & Didilescu, A. C. (2014). Five-year clinical trial using three attachment systems for implant overdentures. Clinical Oral Implants Research, 25, e171-e178. https://doi.org/10.1111/clr.12086
de Albuquerque, R. F., Fromentin, O., Lassauzay, C., & Conceição Pereira Saraiva, M. D. (2018). Patient satisfaction versus retention of implant overdentures with two attachment systems: A randomized trial. Clinical Implant Dentistry and Related Research, 21, 21-31. https://doi.org/10.1111/cid.12675
De Bruyn, H., Lindén, U., Collaert, B., & Björn, A. L. (2000). Quality of fixed restorative treatment on Brånemark implants. A 3-year follow-up study in private dental practices. Clinical Oral Implants Research, 11, 248-255.
De Bruyn, H., Raes, S., Matthys, C., & Cosyn, J. (2015). The current use of patient-centred/reported outcomes in implant dentistry: A systematic review. Clinical Oral Implants Research, 26(Suppl. 11), 45-56. https://doi.org/10.1111/clr.12634
ELsyad, M., Hatem, O., Shawky, A., & Emera, R. (2018). Effect of different degrees of mesial implant inclination on the retention and stability of two-implant mandibular overdentures retained with stud attachments: An in vitro study. The International Journal of Oral and Maxillofacial Implants, 33, 259-268. https://doi.org/10.11607/jomi.5791
Emami, E., Cerutti-Kopplin, D., Menassa, M., Audy, N., Kodama, N., Durand, R., … de Grandmont, P. (2016). Does immediate loading affect clinical and patient-centered outcomes of mandibular 2-unsplinted-implant overdenture? A 2-year within-case analysis. Journal of Dentistry, 50, 30-36. https://doi.org/10.1016/j.jdent.2016.04.009
Engelhardt, F., Zeman, F., Behr, M., & Hahmel, S. (2016). Prosthetic complications and maintenance requirements in locator-attached implant-supported overdentures: A retrospective study. European Journal of Prosthodontics and Restorative Dentistry, 24, 31-35.
Fernandez-Estevan, L., Montero, J., Selva Otaolaurruchi, E. J., & Sola Ruiz, F. (2017). Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study. Journal of Prosthetic Dentistry, 117, 367-372. https://doi.org/10.1016/j.prosdent.2016.07.013
Fernandez-Estevan, L., Selva-Otaolaurruchi, E. J., Montero, J., & Sola-Ruiz, F. (2015). Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients. Medicina Oral Patologia Oral y Cirugia Bucal, 20, e450-e458. https://doi.org/10.4317/medoral.20498
Geckili, O., Cilinger, A., Erdogan, O., Kesoglu, A. C., Bilmenoglu, C., Ozdiler, A., & Bilhan, H. (2015). The influence of inter-implant distance in mandibular overdentures supported by two implants on patient satisfaction and quality of life. International Journal of Prosthodontics, 28, 19-21. https://doi.org/10.11607/ijp.3994
Guédat, C., Nagy, U., Schimmel, M., Müller, F., & Srinivasan, M. (2018). Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up. Clinical and Experimental Dental Research, 4, 132-145. https://doi.org/10.1002/cre2.122
Hong, H. R., Pae, A., Kim, Y., Paek, J., Kim, H. S., & Kwon, K. R. (2012). Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: A finite element analysis. International Journal of Oral and Maxillofacial Implants, 27, e69-e76.
Jabbour, Z., Fromentin, O., Lassauzay, C., Abi Nader, S., Correa, J. A., Feine, J., & de Albuquerque, J. R. F. (2014). Effect of implant angulation on attachment retention in mandibular two-implant overdentures: A clinical study. Clinical Implant Dentistry and Related Research, 16, 565-571. https://doi.org/10.1111/cid.12030
Kappel, S., Giannakopoulos, N. N., Eberhard, L., Rammelsberg, P., & Eiffler, C. (2016). Immediate loading of dental implants in edentulous mandibles by use of Locator® attachments or Dolder® bars: Two-year results from a prospective randomized clinical study. Clinical Implant Dentistry and Related Research, 18, 752-776. https://doi.org/10.1111/cid.12349
Kern, J. S., Kern, T., Wolfart, S., & Heussen, N. (2016). A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: Post-loading implant loss. Clinical Oral Implants Research, 27, 174-195. https://doi.org/10.1111/clr.12531
Khalid, T., Yunus, N., Ibrahim, N., Elkezza, A., & Masood, M. (2017). Patient-reported outcome and its association with attachment type and bone volume in mandibular implant overdenture. Clinical Oral Implants Research, 28, 535-542. https://doi.org/10.1111/clr.12831
Kim, H. Y., Lee, J. Y., Shin, S. W., & Bryant, S. (2012). Attachment systems for mandibular overdentures: A systematic review. Journal of Advanced Prosthodontics, 4, 197-203. https://doi.org/10.4047/jap.2012.4.4.197
Kleis, W. K., Kämmerer, P. W., Hartmann, S., Al-Nawas, B., & Wagner, W. (2010). A comparison of three different systems for mandibular two-implant overdentures: One-year report. Clinical Implant Dentistry and Related Research, 12, 209-218. https://doi.org/10.1111/j.1708-8208.2009.00154.x
Kobayashi, M., Srinivasan, M., Ammann, P., Perriard, J., Ohkubo, C., Müller, F., … … M. (2014). Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems. Clinical Oral Implants Research, 25, 426-434. https://doi.org/10.1111/clr.12156
Krennmair, G., Seemann, R., Fazekas, A., Ewers, R., & Piehslinger, E. (2012). Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: A crossover clinical trial. International Journal of Oral and Maxillofacial Implants, 27, 1560-1568.
Kurtulus, I. L., & Gurbulak, A. G. (2018). The In Vitro comparison of the retention of an implant-supported stud attachment locator and straumann ball attachment at different angulations. Nigerian Journal of Clinical Practice, 21, 639-644. https://doi.org/10.4103/njcp.njcp_276_17
Mackie, A., Lyons, K., Thomson, W. M., & Payne, A. G. (2011). Mandibular two-implant overdentures: Three-year prosthodontic maintenance using the locator attachment system. International Journal of Prosthodontics, 24, 328-331.
Marinis, A., Afshari, F. S., Yuan, J. C., Lee, D. J., Syros, G., Knoernschild, K. L., … Sukotjo, C. (2016). Retrospective analysis of implant overdenture treatment in the advanced prosthodontic clinic at the University of Illinois at Chicago. Journal of Oral Implantology, 42, 46-53. https://doi.org/10.1563/aaid-joi-D-14-00089
Matthys, C., Vervaeke, S., Jacquet, W., & De Bruyn, H. (2018). Impact of crestal bone resorption on quality of life and professional maintenance with conventional dentures or Locator-retained mandibular implant overdentures. Journal of Prosthetic Dentistry, 120, 886-894. https://doi.org/10.1016/j.prosdent.2017.11.028
Mombelli, A., van Oosten, M. A., Schurch, E., & Lang, N. P. (1987). The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiology and Immunology, 2, 145-151. https://doi.org/10.1111/j.1399-302X.1987.tb00298.x
Parmar, S., Karir, N., Walmsley, D., & Patel, U. (2013). Long and short-term management of implant-supported mandibular overdentures. Dental Update, 40(830-2), 834-835. https://doi.org/10.12968/denu.2013.40.10.830
Preciado, A., Del Río, J., Suárez-García, M. J., Montero, J., Lynch, C. D., & Castillo-Oyagüe, R. (2012). Differences in impact of patient and prosthetic characteristics on oral health-related quality of life among implant-retained overdenture wearers. Journal of Dentistry, 40, 857-865. https://doi.org/10.1016/j.jdent.2012.07.006
Reissmann, D. R., Dard, M., Lamprecht, R., Struppek, J., & Heydecke, G. (2017). Oral Health-related quality of life in subjects with implant-supported prothesis: A systematic review. Journal of Dentistry, 65, 22-40. https://doi.org/10.1016/j.jdent.2017.08.003
Scherer, M. D., McGlumphy, E. A., Seghi, R. R., & Campagni, W. V. (2014). Comparison of retention and stability of two implant-retained overdentures based on implant location. Journal of Prosthetic Dentistry, 112, 515-521. https://doi.org/10.1016/j.prosdent.2014.03.003
Slade, G. D. (1997). Derivation and validation of a short-form oral health impact profile. Community Dentistry and Oral Epidemiology, 25, 284-290. https://doi.org/10.1111/j.1600-0528.1997.tb00941.x
Srinivasan, M., Schimmel, M., Badoud, I., Ammann, P., Herrmann, F. R., & Müller, F. (2016). Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments - An in vitro study. Clinical Oral Implants Research, 27, 604-611. https://doi.org/10.1111/clr.12643
Stephens, G. J., di Vitale, N., O'Sullivan, E., & McDonald, A. (2014). The influence of inter-implant divergence on the retention characteristics of locator attachments, a laboratory study. Journal of Prosthodontics, 23, 467-475. https://doi.org/10.1111/jopr.12144
Sultana, N., Bartlett, D. W., & Suleiman, M. (2017). Retention of implant-supported overdentures at different implant angulations: Comparing Locator and ball attachments. Clinical Oral Implants Research, 28, 1406-1410. https://doi.org/10.1111/clr.13003
Trakas, T., Michalakis, K., Kang, K., & Hirayama, H. (2006). Attachment systems for implant retained overdentures: A literature review. Implant Dentistry, 15, 24-34. https://doi.org/10.1097/01.id.0000202419.21665.36
Troeltzsch, M., Troeltzsch, V., Brodine, A. H., Frankenberger, R., Messlinger, K., & Troeltzsch, M. (2013). Clinical performance and peri-implant parameters of 132 implants supporting locator-retained overdentures: A case series of 33 patients. The International Journal of Oral and Maxillofacial Implants, 28, 1132-1139. https://doi.org/10.11607/jomi.3009
Zhang, L., Lyu, C., Shang, Z., Niu, A., & Liang, X. (2017). Quality of life of implant-supported overdenture and conventional complete denture in restoring the edentulous mandible: A systematic review. Implant Dentistry, 26, 945-950. https://doi.org/10.1097/ID.0000000000000668

Auteurs

Carine Matthys (C)

Clinic for Removable Prosthodontics, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.

Stijn Vervaeke (S)

Department of Periodontology and Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.

Jos Besseler (J)

Besseler Dental Clinic, Enschede, The Netherlands.

Hugo De Bruyn (H)

Department of Periodontology, Oral Implantology, Removable and Implant Prosthodontics, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.
Department of Dentistry - Implantology & Periodontology, Radboud University Medical Center, Research Institute Health Sciences, Nijmegen, The Netherlands.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male